A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron F3S-B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron F3S-B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron F3S-B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron F3S-B should contain:
- informations concerning technical data of Omron F3S-B
- name of the manufacturer and a year of construction of the Omron F3S-B item
- rules of operation, control and maintenance of the Omron F3S-B item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron F3S-B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron F3S-B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron F3S-B.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron F3S-B item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    F3S - B 2 Safet y Light Curtain Category 2 Safety Design Suitable for Det ecting Human Presence in Hazardous Areas H T ype 2 Safety Light Cur tain oper ates independentl y or as part of ex ist ing safet y systems. M eets ca t egory 2, 1 or B. (As defined by European s tandard EN954 - - 1) H Complianc e with I EC 61496 - - 2 (1997) (T ype 2 AOPD), E[...]

  • Page 2

    F3S-B 3 Ordering Inf ormation — continued Descr iption Part num ber Protective height Weight (without accessories) Optic al resolution Beam pitch No. of beams Stand-Alone Ma ster Unit Slave Uni t 300 mm 0.9 kg 80 75 mm 4 F3S-B047P F3S-BM047P jj F3S-BS047 450 mm 1.2 kg 8 0 5 6 F3S-B067P F3S-BM067P jj F3S-BS067 600 mm 1.5 kg 8 F3S-B087P F3S-BM087P [...]

  • Page 3

    F3S-B 4 Rece iver Emitter Indicator area Extension cable Protective height J ST AND-ALONE TYPE This is the most comm on configuration, and it is used to protect a hazar dous part of a machine when approached from one direct ion onl y . J SERIES CONNECTION TYPES When your application requires an additional protective zone, for example, t o prevent s[...]

  • Page 4

    F3S-B 5 Specificati ons T able - - continued from previous page Ty p e F3S - B jjj P( S e eN o t e1 ) Stand-Alone F3S-B jjj P jj (See Note 1) Master Unit for series connection F3S-B jjj (See Note 1) Master Unit for series connection Protective height 300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1, 350 / 1,500 / 1,650 m m 300 / 450 / 600 / 750 m m [...]

  • Page 5

    F3S-B 6 J INDICA TORS ON OFF UNSTAB POWE R INTER - - LOCK EXT.TEST BLANKI Beam line mark (Optical-axis line mark) ON- state indi cator (Green) IR-power indicator (Orange) Interl ock indi cator (Y ellow) OFF -state in dicator (Red) Emi tter Indicators Receiver Indicators Extern al test/ blanking indicator (Green) Instabilit y indicator (Orange) Emi [...]

  • Page 6

    F3S-B 7 J SERIES CONNECTION TYPES The following charts show the response time of combinations of a Master Unit and a Slave Unit, and then t hey show combinations of a Slave Unit connected in series. For example, the r esponse time of t he combination of F3S-BM122P30 and F3S-BS302 is 30 ms. Master unit Response Time per Slave Unit F3S- BS122 BS182 B[...]

  • Page 7

    F3S-B 8 Engineeri ng Data J OPERA TING RANGE F3S-B122P Perpendicular to Center Line of Lenses Parallel to Center Line of Lenses Distance Y (mm) Distance X (m) Distance X (m) - - 300 - - 200 - - 100 0 100 200 300 024 68 Y X - - 300 - - 200 - - 100 0 100 200 300 02 46 8 Y X Distance Y (mm) F3S-B662P Perpendicular to Center Line of Lenses Parallel to [...]

  • Page 8

    F3S-B 9 Operation J I/O CI RCUIT DIAGRAM IR- - light indicator 2 3 1 4 7 ON- -s tate indicator 2 7 Instability indicator 3 1 4 5 6 6 5 Green Brown White Y ellow Blue Brown Green White Y ellow Pink Grey Pink Grey +24 V 0V Load Load Load Instability Blue output RS- - 485(A) RS- - 485(B) Interlock indicator Ext. test/blanking indicator External test i[...]

  • Page 9

    F3S-B 10 Dim ensions Unit: m m J F3S - B SAFETY LIGHT CURT AIN Part number A( Protec tive height) B (Ful l length) F3S-B122 300 343 F3S-B182 450 493 F3S-B242 600 643 F3S-B302 750 793 F3S-B362 900 943 F3S-B422 1050 1093 F3S-B482 1200 1243 F3S-B542 1350 1393 F3S-B602 1500 1543 F3S-B662 1650 1693 M12 connector 40.3 3 34 10.5 30 3 9.5 Mas ter Un it M12[...]

  • Page 10

    F3S-B 11 J MOUNTING BRACKET (TOP AND BOTTOM) 22 2 R1.7 5 5.5 R2.75 . R4.5 ∅ 25.5 3.5 20 ° 35 ° 46 16 12 30 20 36 J MOUNTING PLA TE Only supplied with types which have a protective height of 1,050 m m or longer (including intermediate brackets). Only needed for rear mounting. 42.74 36.5 7 5 12 5.5 R2.75 6.25 3 22.5 28.74 4 20 J INTERMEDIA TE MOU[...]

  • Page 11

    F3S-B 12 O pt i ons ( O r d er S eparate l y ) Unit: m m J EXTENSION CABLE (SET OF 2: EMITTER = GRA Y , RECEI VER = BLACK) F39-JB1A (L = 3 m) F39-JB2A (L = 7 m) F39-JB3A (L = 10m ) 42 L M12 ∅ 15 Round vinyl- - insulated cord 5.7 mm dia. (32 @ 0.1 m m dia. each) 8 cores J F39 - EU1E OPTIONAL FUNCTI ON KIT This set includes the following i tem s: D[...]

  • Page 12

    F3S-B 13 J CONNECTOR (MAIN UNIT END) Front view Pin no. Signal name Wire color Receiv er Emi tter of Extension Cable 1 Control output 2 Relay monitoring input White 1 7 6 2 24 VDC 24 VDC Brown 1 2 8 6 5 3 Control output 1 External test input Green 2 8 5 3 4 4 Ins tability o utput Interlock selection input Y ellow 3 4 5 RS-485 (A) RS-485 (A) Grey 6 [...]

  • Page 13

    F3S-B 14 RS- - 485(A) (Gr ey 5) RS- - 485(B) (Pink 6) K3 E1 S1 k1 k2 E1 S2: Restart interlock reset switch S2 Emitter Emitter Recei ver k1, k2: Auxiliary contact to m oni- tor the condition of the final relay 24 VDC (Brown 2) 0V( B l u e7 ) Instability (Y ellow 4) Interlock selection (Y ellow 4) 24 VDC (Brown 2) 0V( B l u e7 ) Relay monitoring (Whi[...]

  • Page 14

    F3S-B 15 J COMPONENT NAMES AND FUNCTIONS OF THE F39 -E1 I NTERF ACE UNI T SEND to HS-485 indicator (Red) SEND to HS-232C indicator (Y ellow) M8 Connector (RS-485) 9pin D-Sub Connector (HS-232C) Communication indicator (Green) SEND to RS -485 I ndicator (Red) Lit when the F39-E1 sends data t o the F3S-B via RS - 485. SEND to RS-232C Indi cator (Y el[...]

  • Page 15

    F3S-B 16 J SOFTW ARE INST ALLA TION Copy the file ”F39-U1E_ver#.#. exe” and F39-U1E_ver#.#dat f rom the 3.5- - inch floppy disk (enclosed wi th t he product) onto the har d disk of the PC. J FUNCTION DESCRIPTI ON Start Inter lock When the Start interlock function is used, the F3S-B does not go to the ON-st ate automatically after power ON. Int [...]

  • Page 16

    F3S-B 17 Precautions W ARNING 1. Do not use the F3S-B on m achines that can not be stopped by electrical control in case of an em ergency . 2. Do not use the F3S-B in flamm able or explosi ve environment s. 3. Always maintain the safet y distance between F3S-B and a hazardous part of the machine. Serious injury may r esult if the machine does not s[...]

  • Page 17

    F3S-B 18 W ARNING When using multiple sets of the F3S-B, install them so that m utual interference is not incurred. ! Incorrect Incor rect Incorrect Emitter 1 Emitter 2 Recei ver 1 Recei ver 2 RS- - 485 RS - - 48 5 RS- - 485 Emitter 1 Recei ver 1 Emitter 2 Recei ver 2 Emitter 1 Recei ver 1 Emitter 2 Recei ver 2 J AL TERNA TE EMITTERS AND RECEI VERS[...]

  • Page 18

    F3S-B 19 W ARNING 1. The F3S-B is a TYPE 2 electro-sensitive pr otective equip- ment, int ended to be used as or with the safety r elated part of control syst em to category 2,1, or B as defined in the European standard EN954-1. Do not use the F3S-B in category 3 or 4 systems. 2. A qualified person, as deter mined by local regulations, must confirm[...]

  • Page 19

    Terms an d Conditions of Sal e 1. Offer; Acc eptance . These terms and conditions (thes e "T erms") ar e deemed par t o f all quotes , agreements, pur chase orders, ac kno wl edgment s, price lists , catalogs, m anuals , brochures and other documents, whether electronic or in writing, relating to t he sale of products or ser vi ces (colle[...]

  • Page 20

    2052121/,1( *OREDOKWWSZZZ RPURQFRP 86$KWWSZZZ RPURQFRPRHL &DQDGDKWWS ZZZ RPURQFD Cat. No. GC SAFETY-3 07 /0 5 Specifications subject to change without notice Printed in USA 20521&$1$'$,1& 0LOQHU$YHQXH 7 RURQWR2QWDU LR?[...]