Mobi DualScan Ultra manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Mobi DualScan Ultra, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Mobi DualScan Ultra one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Mobi DualScan Ultra. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Mobi DualScan Ultra should contain:
- informations concerning technical data of Mobi DualScan Ultra
- name of the manufacturer and a year of construction of the Mobi DualScan Ultra item
- rules of operation, control and maintenance of the Mobi DualScan Ultra item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Mobi DualScan Ultra alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Mobi DualScan Ultra, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Mobi service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Mobi DualScan Ultra.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Mobi DualScan Ultra item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T a lking Ear a n d F or e hea d TH E RMO M E TE R T M D ua l S c a n U L TR A plus Pulse Meter[...]

  • Page 2

    U ser’s M an ua l f or D u a l Sca n ™ U ltr a D igital T h er mo meter - Thank you for purchasing our DualScan ™ Ultra thermometer. For optimal use of this product, be sure to read this user manual before any operation. - Remove safety tab from battery. Open battery case and gently pull out the plastic safety tab from underneath the battery.[...]

  • Page 3

    WARNING Use of this thermometer is not intended as a substitution for consultation with your physician. Measurement results are for reference only. They cannot be used as a clinical assessment or medical diagnostic basis. Contact your physician if you have or suspect any health concerns. Don't touch or blow infrared sensor. *A soiled Infrared [...]

  • Page 4

    - D on 't us e th e p rod u ct for oth e r p ur po ses t he n thos e pr op os e her ei n. - T hi s i s n ot a wat erp ro of dev i ce. Cle a n i t only w it h dam pe n ed cl o th gen tl y. - It i s u ns afe and h a za r do u s t o le a ve th e p ro du ct e x p os ed t o any ch e mica l so lvent, d ir e c t su nshin e or h i gh te m pera tu re .[...]

  • Page 5

    In di c ate s AM o r P M w he n t i me o f day is dis p lay e d be lo w i t Nume ri cal Re adin gs f or Te m pe r a tu re / Tim e / P ul se Me mo ry N um be r hea di ng ( Me mor y N u mbe rs dis pl ay ed be lo w) Cale nd a r Yea r / N um be r o f t h e p r evi ous r ea di ng in Me mor y Calend a r M o nth Cale nd a r D ay In di ca te s Ea r T emper[...]

  • Page 6

    PRI M A R Y FUN C TI O N S Ca le ndar D at e fa lls w it hi n Gr ego r ia n ca l en da r yea r 2001–2099. Time o f D ay is s how n in 24 ho ur s hi fts. T he i ni tia l date fo r a powered uni t is s et as J an u ar y 1 st o f t he man uf a ct u ri ng ye a r. Ro om Temp e rat u re i s d i sp l aye d wi t h T i me of Da y ( al te rnat in g eve r y[...]

  • Page 7

    Fo r p r ope r me as ur em e nts alwa ys stor e t he device i n approp r ia te temper at ur e of amb ie n t tempe r atur e is l ik e ly t o d ete ri or a te m eas ur in g a c cu ra cy . W h en a wh ic h a ther mom et er is lo ca te d , or any at te m pt t o pe r for m a tempe ra tur e r ea din g in f r on t o f an air co n diti on er or h ea t in g[...]

  • Page 8

    To m ea su re Ea r T e mp er at ure c over from t h e un it , and inser t the s li m me r E ar Probe tip jus t s li g htl y into the e a r o pen in g, th en press an d ho ld th e Ea r B ut t on t o meas ur e t he bo dy tempe r at ur e. Gri p u ni t c omf o rt a bl y a n d depre s s ONLY th e Ea r Bu tt o n. O nc e th e u nit has a measuremen t , yo[...]

  • Page 9

    W he n i n Cl o ck Mo de T he d is p la y wi ll s h ow Time a s: Yea r , Mont h , Date, H our, a nd Mi nu t e wi th t he d i spl a ys th e c ur ren t Time and R o om Temperature, alternating every 5 sec on ds . O th e r w is e, p ress a nd release T ALK and t h e unit w i ll vis i bl y disp la y, a nd au di b ly s pe ak , t h e c ur re n t T ime a [...]

  • Page 10

    To retrieve Re adi n gs fr o m t he M em o ry Press and re le as e t he SET B u tt o n t o r et r ieve t h e mo st re c en t re a di n g r e cord ed in the Me m or y . I t w il l sh ow th e B od y Tempe r at ur e, t h e T y pe o f R ead in g (ea r or fo rehea d ), t h e F ev e r / No Fever c ol o red lig h t, t h e Date i t wa s r ec ord ed , and t[...]

  • Page 11

    To c hange be t ween Fa hre n heit or Ce lsi us Press the E a r B u tton and th e T A LK Bu t t on t o get h er. The unit wi l l c h an ge f ro m wh ic h ever sc al e i t is i n , t o th e o t he r …Ce lsius or Fa hrenhe i t. This se t ting ch an ge wi ll be sp o ke n i f t h e T a lkin g Feat ur e ha s n ot been d is ab le d. To s et to Sleep Mo[...]

  • Page 12

    R E C OM MEN D A TION S R E P L A CE B AT T E RIE S Fo r u s ers n o t f am i li ar wi th d ig ita l t h er mome ter s, i t i s rec om men de d t ha t yo u m ea s u re th e sa me ear 3 times during initia l usage. T he max i mum re a d i ng sh al l Wa it abo ut 30 se co nd s befo r e meas u ri n g t h e s a me pa t ie n t agai n t o fa ct or i n ch[...]

  • Page 13

    M AINTENANC E , S T O R A GE AND C ALIB R A TIO N C AR E AN D CLEANIN G Ma intena nc e : 1. Rem o ve a ll s ta ins fr om th e d evice w it h a soft, dr y c lo th. 2. Clean the t i p of t h e p ro be a s f o ll o ws : W i pe t h e s u rfa c e ge n tly w i th a sw ab of co t to n o r a s of t c l ot h moi sten ed wi t h a lc oh o l u n ti l n o d i r[...]

  • Page 14

    1 4 UNIT S PE CIFI C A TI O N S • Product Name: DualScan Ultra Thermomete r • Model: 7012 0 • Power supply: DC3V (2 x AAA battery ) • Temperature Sensing Part: IR senso r • Measuring range: 32.0°C - 42.9°C (89.6°F -109.3°F ) • Room Temperature: 5.0°C - 59.9°C 141.0°F -139.8°F ) • Measuring accuracy: +1- 0.2°C (or +1- 0.4°F) [...]

  • Page 15

    0197 EX P L AN A TI O N O F S Y MB O L S 1 5 T ype B App l ie d p ar t Di sp os al i n a cco rd an c e w it h D ir ec ti ve 2002/96/EC ( WEEE ) T he na m e an d t h e a dd r es s of t he m an ufa c tu rer T he na me and t h e ad dr ess o f t he au t ho r ise d r ep r esen tat ive i n t h e E u ro pea n C o mm u nit y C om p l ie s wi t h t he Eur o[...]

  • Page 16

    GUI D ANCE AN D M ANU F A C TURER'S D EC L A R A TIO N 1 6 G ui da nc e an d ma n u fa ctu re r 's de c l ar ati o n - e l ect r om ag n etic e mi ssi on s bel o w. The cu sto me r o r t he user mus t ensure that it is used i n such an e n vi r on m en t . Em is si ons Te s t Co m p li a nc e E l ec tr o magne tic e nv ir on men t - gu id[...]

  • Page 17

    Immunity test IEC 60601 test lev el Compliance lev el Electrostatic discharge (ESD) lEC 61000-4-2 ± 6 kV contact ± 8 kV air Electrical fast transient/burst IEC 61000-4-4 ± 2kV for pow er supply lines ± 1kV for input/ output lines ± 1kV dif ferential mode ± 2kV common mode V oltage dips , shor t inter r uptions and v olta ge variations on powe[...]

  • Page 18

    The device is intended for use in. the electroma gnetic en vironment specified below . The customer or the user should assure that it is used in suc h an en vironment. Conducted R F lEC 61000-4-6 P or table and mobile RF Communications equipment should be used no closer to any par t of the device , including ca bles , than the recommended separatio[...]

  • Page 19

    assess the electromagnetic environment due to fix ed RF transmitters, an electromagnetic site sur v ey should be considered. If the measured field strength in the loca tion in which the device is used e x ceeds the applica ble RF compliance le v el abov e , should be obser v ed to v erify nor mal opera tion. If abnor mal perfor mance is obser v ed,[...]

  • Page 20

    D EC L A R A TION O F C O NFORMI T Y 2 0 NOTE 2 T he s e g ui de li ne s may no t a ppl y i n a ll s itu at i ons . Elec tro ma gne ti c an d people . Fo r t r ansm i tt er s r a te d at a m axim u m o ut pu t po w er no t lis te d a bove , t h e rec om me n ded sep ara t io n dis t an ce d i n met e rs ( m) can be e st im a te d us ing th eeq u at[...]

  • Page 21

    T roubles Ba tter y symbol on L CD Check lists Counter measures “Lo” on screen (result below 32.0 ℃ or 89.6 ℉ ) “Hi” on screen (result below 42.9 ℃ or 109.3 ℉ ) No response/ A utoma tic reset when pulling out insula tor Ba tter y drained Ba tter y in wrong polarity? P oor ba tter y contact Change ba tteries T ak e out ba tter y , re[...]

  • Page 22

    LI M IT E D W AR R AN T Y Mobi T echnologies, Inc. warrants this product to be free from defects in material and workmanship for a period of ninety (90) days from the date of purchase. Should this product prove to be defective at any time during the warranty period, Mobi T echnologies, Inc. will, at its option, either replace or repair it without c[...]