Hoshizaki DCM-750BAH(-OS) manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hoshizaki DCM-750BAH(-OS), along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hoshizaki DCM-750BAH(-OS) one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hoshizaki DCM-750BAH(-OS). A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hoshizaki DCM-750BAH(-OS) should contain:
- informations concerning technical data of Hoshizaki DCM-750BAH(-OS)
- name of the manufacturer and a year of construction of the Hoshizaki DCM-750BAH(-OS) item
- rules of operation, control and maintenance of the Hoshizaki DCM-750BAH(-OS) item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hoshizaki DCM-750BAH(-OS) alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hoshizaki DCM-750BAH(-OS), and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hoshizaki service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hoshizaki DCM-750BAH(-OS).

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hoshizaki DCM-750BAH(-OS) item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Models DCM-750BAH(-OS) DCM-750BWH(-OS) Cubelet Icemaker / Dispenser Hoshizaki America, Inc. Issued: 5-7-2008 Revised: 4-6-2010 I N S T R U C T I O N M A N U A L ®[...]

  • Page 2

    2 IMPOR T ANT Only quali ed ser vice technicians should inst all, ser vice , and maintain the icemaker . No installation, service, or maintenance should be under tak en until the technician has thor oughly r ead this Instruction Manual. Like wise, the owner/manager should not pr oceed to operat e the icemaker until the installer has instructed t[...]

  • Page 3

    3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 4 I. Specications ...................................................................................................................... 5 A. Nameplate Rating .............................................[...]

  • Page 4

    4 Impor tant Safety Inf ormation Throughout this man ual, notices appear t o bring your at tention t o situations which could result in death, serious injur y , or damage to the unit. W ARNING Indicates a hazar dous situation which could r esult in death or serious injury . C A UTION Indicates a sit uation which could result in dama ge to the unit.[...]

  • Page 5

    5 MODEL NUMBER DCM-750BAH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MA X. C I RC . B REA K E R (CA NAD A [...]

  • Page 6

    6 MODEL NUMBER DCM-750BAH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4 HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MA X. C I RC . B REA K E R (CA NA[...]

  • Page 7

    7 MODEL NUMBER DCM-750BWH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MA X. C I RC . B REA K E R (CA NAD A O[...]

  • Page 8

    8 MODEL NUMBER DCM-750BWH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MA X. C I RC . B REA K E R (CA NAD [...]

  • Page 9

    9 B. Dimensions/Connections 1 . DCM-750B AH Unit: in. [mm][...]

  • Page 10

    1 0 2. DCM-750BAH-OS Unit: in. [mm][...]

  • Page 11

    1 1 3. DCM-750BWH Unit: in. [mm][...]

  • Page 12

    1 2 4. DCM-750BWH-OS Unit: in. [mm][...]

  • Page 13

    1 3 Unit: in. (mm) 5. DCM-750BAH(-OS) or DCM-750B WH(-OS) on optional SD-70 0 or SD-750 Stand SD-70 0 34" (864) SD-750 34" (864) 6-1/8" (1 56) SD-70 0 26-1/2" (673) SD-750 26-3/4" (680) SD-70 0 80-1 1/1 6" (2050) SD-750 80-1 5/16" (2057) SD-70 0 1/8" (3) SD-70 0 1/8" (3) SD-70 0 28-1/4" (71 8) SD-75[...]

  • Page 14

    1 4 II. Installation and Operating Instr uctions W ARNING 1 . This icemaker must be inst alled in accor dance with applicab le national, stat e, and local regulations . 2. CHOKING HAZARD: Ensure all components, f astener s, and thumbscre ws are secur ely in place af ter inst allation. Make sur e that none ha v e f allen into the stor age bin. A. Ch[...]

  • Page 15

    1 5 T op P anel Side P anel Side P anel F ront P anel Apron P anel Connect or s B. How t o Remo v e Panels See F ig. 1 or Fig. 2 • F ront P anel: Remo ve the scr e w . Lif t up and tow ards you. Disconnect the connect ors on push-but ton models. • T op P anel: Lif t up at front slightl y , push rearw ard and lif t of f . • Apron P anel: R emo[...]

  • Page 16

    1 6 C. Location C A UTION 1 . This icemaker is not int ended f or outdoor use. Nor mal operating ambient temper atur e should be within 45°F t o 1 00°F (7°C to 38°C); Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker , f or e xt ended periods, outside of these normal temperatur e ra[...]

  • Page 17

    1 7 E. Electrical Connection W ARNING 1 . Electr ical connection must be har d-wired and must meet national, st at e, and local electrical code requir ements. F ailure t o meet these code requir ements could result in death, electric shoc k, serious injur y , re, or e xtensiv e damage to equipment. 2. This unit requires an independent po wer sup[...]

  • Page 18

    1 8 F . W ater Suppl y and Dr ain Connections See F ig. 4, 5, or 6 W ARNING 1 . W ater suppl y and drain connections must be installed in accor dance with applicable national, st at e , and local r egulations. 2. Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C). Operation of the icemak er , f or ext ended per io[...]

  • Page 19

    1 9 1 . Icemak er • Icemaker w ater suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended f or the icemaker w ater supply line . • An icemaker w ater supply line shut-of f val v e and drain val ve should be installed. • Stor age bin and drip tra y drain outlets are 3/4" FPT . A minim[...]

  • Page 20

    20 Condenser W at er Supply Inlet 1/2" FPT Condenser Drain Outlet 3/8" FPT Icemaker W at er Supply Inlet 1/2" FPT Drip T ra y Drain Outlet 3/4" FPT 2. W at er -Cooled Condenser a) Connection to an Open Dr ain Sy stem • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubi[...]

  • Page 21

    21 b) Connection to a Closed Loop S yst em • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended f or the condenser wat er supply line. • Condenser r etur n outlet is 3/8" FPT . A minimum of 3/8" OD hard pipe is r ecommended for the condenser return line. • S[...]

  • Page 22

    22 G. F inal Chec klist W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews ar e securel y in place af t er installation. Make sur e that none hav e f allen into the stor age bin. 1) Is the icemaker le v el? 2) Is the icemaker in a sit e where the ambient t emperatur e is within 45°F to 1 00°F (7°C to 38°C) and the wat[...]

  • Page 23

    23 H. Star t up W ARNING 1 . All par ts are f act or y -adjusted. Improper adjustments ma y adv er sely af fect saf ety , performance, component lif e, and warranty cov erage. 2. If the icemaker is tur ned of f , w ait f or at least 3 minut es befor e restar ting the icemaker t o pre vent damage t o the compr essor . 3. At star tup, conrm that a[...]

  • Page 24

    24 F ig. 8 9) Disengage the saf et y s witch. Mov e the control s witch to the "OFF" position, then mov e the pow er s witch to the "OFF" position. T ur n of f the power suppl y . 1 0) Clean the st orage bin liner and the st orage bin cov er using a neutral cleaner . Rinse thoroughl y af t er cleaning . Replace the st orage bin [...]

  • Page 25

    25 III. Cleaning and Maintenance W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews ar e securel y in place af t er any cleaning or maint enance is done to the unit. Make sure that none ha ve f allen into the st orage bin. A. Cleaning and Sanitizing Instructions Hoshizaki recommends cleaning and sanitizing this unit at le[...]

  • Page 26

    26 1 . W ater S yst em a) Cleaning Solution Dilute 9.6  . oz. (0.29 l) of Hoshizaki "Scale A wa y" with 1 .6 g al. (6.0 l) of war m w at er . b) Cleaning Pr ocedure 1) Close the icemaker w ater suppl y line shut-of f val ve . 2) Mov e the control s witch to the "DRAIN" position and allow the w ater s y st em to dr ain f or 5 [...]

  • Page 27

    27 1 3) Af t er the gear mot or star ts, mo ve the contr ol s witch to the "DRAIN" position and allow the wat er sy st em to dr ain f or 5 minutes . Note: If you do not sanitiz e the unit, mo v e the contr ol s witch to the "ICE" position af ter the wat er sy st em drains . Allow the icemaker t o r un f or 30 minutes , then mo v[...]

  • Page 28

    28 c) Cleaning and Sanitizing Pr ocedure 1) Mov e the control s witch to the "OFF" position, then turn off the po wer supply . 2) Remo ve the fr ont and t op panels, then mo ve the po wer s witch to the "OFF" position. 3) Remo ve the st orage bin co ver . 4) Remo ve the mot or brac ket thumbscr e ws, r st from the v er tical [...]

  • Page 29

    29 B. Maintenance This icemaker m ust be maintained individuall y , ref erring to the instruction manual and labels pro vided with the icemaker . The schedule below is a guideline. More fr equent maintenance , howe ver , may be r equired depending on wat er qualit y , the icemaker's envir onment, and local sanitation regulations . Consult with[...]

  • Page 30

    30 C. Pr eparing the Icemak er f or Long Stor age C A UTION When st or ing the icemak er f or an ext ended time or in sub-freezing temper atur es , f ollow the instructions below to pr ev ent damage. When the icemak er is not used for t wo or thr ee day s under nor mal conditions, it is suf ficient t o onl y mov e the control s witch to the "O[...]

  • Page 31

    31 4) At tach a compressed air or carbon dio xide supply t o the condenser water suppl y line drain v alv e . 5) Open the wat er regulating v al v e b y using a scr e w driver t o pr y up on the spr ing r etainer under neath the spring. While holding the v al v e open, b lo w out the condenser using the compressed air or carbon dio xide supply unti[...]

  • Page 32

    32 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A2GE10B[...]