Hoshizaki KML-700MWH-M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Hoshizaki KML-700MWH-M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Hoshizaki KML-700MWH-M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Hoshizaki KML-700MWH-M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Hoshizaki KML-700MWH-M should contain:
- informations concerning technical data of Hoshizaki KML-700MWH-M
- name of the manufacturer and a year of construction of the Hoshizaki KML-700MWH-M item
- rules of operation, control and maintenance of the Hoshizaki KML-700MWH-M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Hoshizaki KML-700MWH-M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Hoshizaki KML-700MWH-M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Hoshizaki service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Hoshizaki KML-700MWH-M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Hoshizaki KML-700MWH-M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Hoshizaki “A Superior Degree of Reliability” www .hoshizaki.com Model KML-700MWH-M Low-Profile Modular Crescent Cuber Hoshizaki America, Inc. Issued: 10-13-2009 I N S T R U C T I O N M A N U A L ™[...]

  • Page 2

     IMPORTANT Only qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/manager should not proceed to operate the icemaker until the installer has instructed them on its pr[...]

  • Page 3

    3 CONTENTS Important Safety Information ................................................................................................. 4 I. Specications ..................................................................................................................... 5 A. Nameplate Rating ...................................................[...]

  • Page 4

    4 Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury. CAUTION Indicates a situation which could result in damage to the unit. IMPORTANT Indic[...]

  • Page 5

    5 MOTOR-COMPRESSOR THERMALL Y PROTECTED, NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City , GA www .hoshizaki.com ICE MAKER WITHOUT STORAGE MEANS 45FE COMPONENT I. Specications A. Nameplate Rating 1. KML-700MWH-M (water-cooled marine) See the nameplate for electrical and refrigeration specications. This nameplate is locate[...]

  • Page 6

    6 B. Dimensions/Connections 1. KML-700MWH-M (water-cooled marine) Unit: in. (mm)[...]

  • Page 7

    7 II. Installation and Operating Instructions WARNING 1. This icemaker must be installed in accordance with applicable international, national, state, and local regulations. . CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/storage[...]

  • Page 8

    8 C. Location CAUTION 1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect ic[...]

  • Page 9

    9 E. Electrical Connection WARNING 1. Electrical connection must be hard-wired and must meet international, national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, re, or severe damage to equipment. . This unit requires an independent power supply.[...]

  • Page 10

    10 F. Water Supply and Drain Connections See Fig. 4 or 5 WARNING 1. Water supply and drain connections must be installed in accordance with applicable international, national, state, and local regulations. . Normal operating water temperature should be within 45°F to 90°F (7°C to 3°C). Operation of the icemaker, for extended periods, outs[...]

  • Page 11

    11 Fig. 4 KML-700MWH-M Connection to an Open Drain System 2. Water-Cooled Condenser a) Connection to an Open Drain System • Condenser water supply inlet is 1/" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line. • A condenser water supply line shut-off valve and drain val[...]

  • Page 12

    1 Condenser Return Line Shut-Off Valve Condenser Return Line Drain Valve Icemaker Drain Outlet 3/4" FPT Icemaker Water Supply Inlet 1/" FPT Fig. 5 Condenser Water Supply Inlet 1/" FPT Condenser Return Outlet 3/8" FPT Separate piping to approved drain. Leave a -inch (5-cm) vertical air gap between the end of each pipe[...]

  • Page 13

    13 G. Final Checklist WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the dispenser unit/storage bin. 1) Is the icemaker level? ) Is the icemaker in a site where the ambient temperature is within 45°F to 100°F (7°C to 38°C) and the water [...]

  • Page 14

    14 H. Startup WARNING 1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty coverage. . If the icemaker is turned off, wait for at least 3 minutes before restarting the icemaker to prevent damage to the compressor. 3. To prevent damage to the water pump, do not leave the co[...]

  • Page 15

    15 III. Cleaning and Maintenance WARNING CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the unit. Make sure that none have fallen into the dispenser unit/storage bin. A. Cleaning and Sanitizing Instructions Hoshizaki recommends cleaning and sanitizing this unit at[...]

  • Page 16

    16 8) In bad or severe water conditions, clean the oat switch assembly as described below. Otherwise, continue to step 9. a. Remove the 3 screws securing the oat switch assembly, then remove the assembly. b. Remove the retainer rod from the bottom of the oat switch housing, then remove the oat. Be careful not to bend the retainer rod ex[...]

  • Page 17

    17 2. Sanitizing Procedure - Following Cleaning Procedure 1) Dilute 1.5 . oz. (37 ml or .5 tbs) of a 5.5% sodium hypochlorite solution (chlorine bleach) with .5 gal. (9.5 l) of warm water. ) Remove the front insulation panel. 3) Pour the sanitizing solution into the water tank. 4) Move the service switch to the "WASH" po[...]

  • Page 18

    18 C. Preparing the Icemaker for Long Storage CAUTION 1. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage. . To prevent damage to the water pump, do not leave the control switch in the "SERVICE" position for extended periods of time when the water tank is em[...]

  • Page 19

    19 3) Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve. 4) Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve. 5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the s[...]

  • Page 20

    0 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A1HL10A[...]