Sea-Fire FM200 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sea-Fire FM200, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sea-Fire FM200 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sea-Fire FM200. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sea-Fire FM200 should contain:
- informations concerning technical data of Sea-Fire FM200
- name of the manufacturer and a year of construction of the Sea-Fire FM200 item
- rules of operation, control and maintenance of the Sea-Fire FM200 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sea-Fire FM200 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sea-Fire FM200, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sea-Fire service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sea-Fire FM200.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sea-Fire FM200 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    FM200 ® MODEL FT FIRE EXTINGUISHERS INST ALLA TION INSTRUCTIONS OWNER’S MANUAL THIS MANUAL IS AN INTEGRAL P AR T OF THE SYSTEM AND AS SUCH, THE EXTINGUISHER MUST BE INST ALLED AND MAINT AINED ACCORDINGL Y . READ AND COMPL Y WITH THESE INSTRUCTIONS, W ARNINGS AND LIMIT A TIONS BEFORE INST ALLING. SUIT ABLE FOR USE FT MODELS: 32°F – 130°F ( 0?[...]

  • Page 2

    W ARNING CONCENTRA TED AGENT AND BY-PRODUCT OF APPLICA TION TO FIRE ARE T OXIC. A VOID BREA THING OF FUMES OR PROLONGED EXPOSURE. ACCIDENT AL DIS- CHARGE MA Y OCCUR DURING HANDLING OR INST ALLA TION OF THIS DEVICE, READ AND COMPL Y WITH INSTRUCTIONS, WARNINGS, AND LIMIT A TIONS CONT AINED IN THIS MANUAL. DO NOT LIFT , CARRY , OR HANDLE BY V AL VE. [...]

  • Page 3

    REMINDER: Sea-Fire systems shall be considered as supplementary to the number of portable fire extinguishers required on-board and are designed and intended for enclosed unoccupied compartment installations that are not subject to direct weather or water . SYSTEM OPERA TIONS Sea-Fire units described in this manual are automatically actuated by a he[...]

  • Page 4

    OTHER APPLICA TIONS • Engine Compartments (maximum 150 cubic feet) • Bow Thrusters • Small Generator Set Enclosures • Consoles • Electrical Enclosures • Flammable Liquid Storage Areas • Pump Enclosures • Alternative Fuel Storage Areas In case of a fire and system discharged, the electrical supply to the motor must be discon- nected.[...]

  • Page 5

    Figure 5 Step 8 Secure the detection tubing to the bulkhead by using the clips and screws supplied. Nylon wire ties may be used in lieu of the clips and screws. Note: Do not exceed a bend radius of 6 inches during the routing of the tube. W ARNING WHEN INST ALLING THE DETECTION TUBING, DO NOT KINK THE TUBING AND DO NOT EXCEED THE MINIMUM BEND RADIU[...]

  • Page 6

    Figure 6 THE FT EXTINGUISHER INST ALLA TION IS COMPLETE. INDICA TOR LIGHT OPERA TION All Sea-Fire extinguishers approved for marine applications are packaged with an indicator light and escutcheon. ‘‘The U.S. Coast Guard approval requires an indicator light if this unit is installed for the protection of a boat’s engine compartment.” The in[...]

  • Page 7

    ELECTRICAL SWITCH INDICA TOR LIGHT GROUND IN-LINE FUSE IGNITION IGNITION SWITCH ST ARTER BA TTERY Figure 9 Figure 3 WHILE MAKING ELECTRICAL CONNECTION CAN RESUL T IN INJUR Y FROM FIRE OR ELECTRICAL BURNS. The indicator light is rated for 12 VDC (contact factory for other voltages). Wire in accor- dance with the American Boating and Y acht Council s[...]

  • Page 8

    Before operating the protected vessel, visually inspect pressure gauge for compliance and ensure the supervisory (indicator) light is lit. If gauge reads low in pressure, and or the indica- tor light is extinguished, remove, and replace the system immediately . Never paint or obstruct the detection tube, as this will adversely affect its operating [...]

  • Page 9

    CONDITIONS All Sea-Fire products are tested after manufacture and shipped in perfect working order . Damage noted upon receipt of shipment should be addressed as a shipping claim, the filing of which is the sole responsibility of the consignee for which the total compensatory award will be limited to that appropriated by the carrier . Insured freig[...]

  • Page 10

    ALL FT (STINGER) MODELS ARE APPROVED FOR VERTICAL MOUNTING ONL Y . INTENDED OPERA TING TEMPERA TURE RANGE : 32°F –130°F (0°C – 54°C ) ST ANDARD EQUIPMENT LIST SUPPLIED WITH EACH SYSTEM 1. ONE TUBING KIT , P ART # 130-121 – 10 FOOT TUBE OR 130-122 – 15 FOOT TUBE. 2. ONE BRACKET ASSEMBL Y — Model # Bracket Part # FT-25 122-010 FT-50 122[...]

  • Page 11

    FG/FD/FT/MD/R/C-MODEL Fire Extinguisher MSDS No. SF002 MA TERIAL SAFETY DA T A SHEET Section 1 — Company and Chemical Identification MET ALCRAFT/SEA-FIRE MARINE EMERGENCY PHONE: 1-800-535-5053 9331-A PHILADELPHIA ROAD PHONE: 1-800-445-7680 BAL TIMORE, MARYLAND 21237DA TE: NOVEMBER 10, 2005 http://www .sea-fire.com PRODUCT NAME: Fire Extinguisher [...]

  • Page 12

    Section 7 — Handling and Storage Handle, transport and store carefully and securely to avoid accidental knocking over or other severe physical impacts. Do not expose to direct heat sources. Do not over-pressurize. Section 8 — Exposure Controls/Personal Protection Respiratory: None Protective Gloves: Leather gloves are recommended when handling [...]

  • Page 13

    Section 15 — Regulatory Information U.S. Federal Regulations: The components of this product are either on the TSCA Inventory or exempt (i.e. impurities, a polymer complying with the exemption rule at 40 CFR 723.250) from the Inventory . State Regulations: None Known Section 16 — Other Information NFP A Codes: Health: 1 Flammability: 0 Reactivi[...]

  • Page 14

    SEA-FIRE MARINE SEA-FIRE EUROPE L TD Division of Metalcraft Inc. Unit 7. io Centre. Stephenson Road 9331-A Philadelphia Road Fareham, Hampshire Baltimore, Maryland 21237 USA PO15 5RU, United Kingdom Website: www .sea-fire.com 14[...]