A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron MX3 Plus, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron MX3 Plus one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron MX3 Plus. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron MX3 Plus should contain:
- informations concerning technical data of Omron MX3 Plus
- name of the manufacturer and a year of construction of the Omron MX3 Plus item
- rules of operation, control and maintenance of the Omron MX3 Plus item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron MX3 Plus alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron MX3 Plus, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron MX3 Plus.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron MX3 Plus item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 MX3 Plus English 1 How to obtain meaningful b lood pressure readings 1 2 Ov er vie w 2 3 Preparation 3 4 Operation 4 5 Memor y 7 6 Error : causes and rectifications 8 7 Maintenance and spare par ts 8 8 T echnical data 9 9 General inf or mation about b lood pressure 10 DIA mmHg SYS mmHg MX3 Plus PULSE/min The OMR ON MX3 Plus measures your b lood p[...]

  • Page 2

    F A E D B G C H J K DIA mmHg SYS mmHg MX3 Plus PULSE/min 2 MX3 Plus English • Store the OMR ON MX3 Plus in a dr y , closed place with a temperature between -20°C and 60°C . • Remov e the batteries if you not intend to use the OMR ON MX3 Plus for 3 months or more. Tips f or use • Chec k your b lood pressure at least twice a da y (bef ore bre[...]

  • Page 3

    3 MX3 Plus English Inser t batteries 1 Slide off the batter y cov er . 2 Inser t f our batter ies as indicated in the batter y compar tment and close compar tment Caution ! Use f our identical 1.5V alkaline batteries type AA LR6! PULSE/min SYS mmHg DIA mmHg M MX3 Pl Connect cuff 1 Inser t air plug in air jac ket. L G Fit cuff Caution ! Do not infla[...]

  • Page 4

    MX3 Plus English 4 Note: f or r ight ar m use keep the tube parallel with y our little finger! 4 Hold the end of the cuff and wrap it around y our ar m. Caution ! Be sure the cuff fits closely; do not pinch y our ar m! PULSE/min DIA mmHg SYS mmHg M MX3 Plus D C B P M N V U T S R Q Contr ol functions B Memor y recall button C Star t b utton D On/off[...]

  • Page 5

    MX3 Plus English 5 Caution ! Allow an interval of at least three min utes between two successiv e measurements! 1 Sit comf or tably at a tab le with y our feet flat on the floor and rest y our ar m on the tab le. 2 Relax y our ar m and tur n your palm upward. Caution ! Cuff at hear t height during measurement! PULSE/min DIA mmHg SYS mmHg M MX3 Plus[...]

  • Page 6

    MX3 Plus English 6 Note : the cuff deflates automatically . Caution ! Sit still, do not mov e and do not speak! PULSE/min DIA mmHg SYS mmHg M MX3 Plus PULSE/min DIA mmHg SYS mmHg M MX3 Plus Read displa y 2 Note v alues in your personal b lood pressure pass. 3 Press on/off b utton to tur n off pow er . Note :p ow er automatically shuts of in 5 minut[...]

  • Page 7

    7 MX3 Plus English M PULSE/min DIA mmHg SYS mmHg M MX3 Plus PULSE/min DIA mmHg SYS mmHg M MX3 Plus Recall previous v alues 1 Press on/off b utton to tur n on pow er . 2 Press memor y recall button f or latest and pre vious v alues. Note : displa y shows alternately blood pressures and hear tbeats. 3 Press on/off b utton to tur n off pow er . PULSE/[...]

  • Page 8

    8 MX3 Plus English Indication Err or Cause Rectification Correct Cuff pressure reading low not possib le Mov ement Ve r y w eak ar ter y pulse Cuff pressure too high Low Batteries weak/ Fit f our new identical 1.5V v oltage e xhausted alkaline batteries type AA LR6 Displa y empty • Use a soft, slightly moistened cloth to clean the OMR ON MX3 Plus[...]

  • Page 9

    MX3 Plus English 9 Product name OMRON MX3 Plus Model HEM-742-E Displa y Digital LCD Measuring range Blood pressure: 0 - 299 mmHg / Pulse: 40 - 180 beats/minute Accuracy Pressure: ± 3 mmHg Pulse: ± 5% of display reading Inflation A utomatic by electric pump Deflation A utomatic pressure release valv e Rapid pressure release A utomatic exhaust v al[...]

  • Page 10

    MX3 Plus English 10 Blood cir culation The b lood circulation is responsible f or supplying the body with o xygen. Blood pressure is the pressure e x er ted on the ar teries. The systolic b lood pressure value (higher pressure or top v alue) represents the b lood pressure produced by contraction of the hear t muscle . The diastolic b lood pressure [...]

  • Page 11

    MX3 Plus English 11 •O v erweight • High cholesterol le v el • Smoking • Excessiv e alcohol consumption • Stress and emotional upset • Excessiv e consumption of salt • Lac k of physical e xercise • Genetic/hereditar y predisposition • Underlying illnesses, such as kidne y disorders or endocrine disturbance Blood pressure measureme[...]

  • Page 12

    12 MX3 Plus English[...]