A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron HEM-711, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron HEM-711 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron HEM-711. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron HEM-711 should contain:
- informations concerning technical data of Omron HEM-711
- name of the manufacturer and a year of construction of the Omron HEM-711 item
- rules of operation, control and maintenance of the Omron HEM-711 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron HEM-711 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron HEM-711, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron HEM-711.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron HEM-711 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For Customer Service Call T oll Free 1-800-634-4350 Manufactured by OMRON Distributed by: OMRON HEAL THCARE, INC. 300 Lakeview Parkway V ernon Hills, Illinois 60061 www .omron.com/ohi Copyright © 2001 OMRON HEAL THCARE, INC. 71 1INST Automatic Blood Pressure Monitor with IntelliSense™ Model HEM-711 INSTR UCTION MANU AL SYSTOLIC D IA S T O LIC PU[...]

  • Page 2

    TITLE 3 T ABLE OF CONTENTS Introduction........................................................................................4 Notes on Safety.................................................................................5 Know Y our Unit..................................................................................6 Quick Reference Guide ..[...]

  • Page 3

    TITLE 5 NO TES ON SAFETY • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk and the damage to you and others from happening. • The icons and meanings are as follow . Warning sign Contents Indicates matters in which bodily harm or material damage* may aris[...]

  • Page 4

    TITLE 7 QUICK REFERENCE GUIDE 1. Avoid eating, smoking, and exercising for at least 30 minutes before taking a measurement. 2. Remove tight-fitting clothing from your upper arm. 3. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart. 4. Put your arm through the cuff loop [...]

  • Page 5

    TITLE 9 HO W T O APPL Y THE ARM CUFF 1. If the cuff is assembled correctly , the hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 2. If the cuff is not assembled, pass the end of the cuff furthest from the tubing through the metal D- ring to form a loop. The smooth cloth should be on the inside of[...]

  • Page 6

    TITLE 11 HO W T O T AKE A READING Ready to Measure Initial LCD T est Inflation started. 1. Press the ON/OFF button. a) All display symbols appear for approximately one second. b) When the monitor becomes ready to measure, the Heart Symbol appears on the display . 2. Press the ST ART button and remain still. As the cuff begins to inflate, the monito[...]

  • Page 7

    TITLE 13 HO W T O USE THE MEMOR Y FUNCTION This monitor has a memory capable of storing fourteen sets of readings. Every time you complete the measurement, the monitor automatically stores blood pressure and pulse rate. • Push the button to recall stored readings while the Heart Symbol ( ) is displayed. • When the memory is holding fourteen set[...]

  • Page 8

    TITLE 15 TR OUBLESHOO TING If you continue to have difficulty obtaining a reading, call OMRON HEAL THCARE CUST OMER SERVICE TOLL FREE 1-800-634-4350. Please tell the representative you have an OMRON Model HEM-71 1. Error Indicator Cause Correction Cuff under-inflated. Movement during measurement. Cuff over-inflated (more than 300 mmHg). Battery vol[...]

  • Page 9

    TITLE 17 CARE AND MAINTENANCE T o protect y our monitor from damage, please A VOID the f ollowing: • Subjecting your monitor and cuff to extreme temperatures, humidity , moisture, and direct sunlight. • Folding the cuff and tubing tightly . • Inflating the monitor over 280 mmHg. • Disassembling the monitor . • Subjecting the monitor to st[...]

  • Page 10

    19 SPECIFICA TIONS Model: HEM-711 Display: LCD Digital Display Measurement Range: Pressure: 0 to 280 mmHg Pulse: 40 to 180/minute Accuracy/Calibration: Pressure: ± 3 mmHg or 2% of reading Pulse: ± 5% of reading Inflation: Automatic by electric pump Deflation: Active electronic control valve Rapid Pressure Release: Active electronic control valve [...]