Omron M6 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron M6, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron M6 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron M6. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron M6 should contain:
- informations concerning technical data of Omron M6
- name of the manufacturer and a year of construction of the Omron M6 item
- rules of operation, control and maintenance of the Omron M6 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron M6 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron M6, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron M6.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron M6 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Digital A utomatic Blood Pressure Monitor Model M6 • Instruction Man ual • Mode d’emplo i • Gebrauc hsanweisung • Manuale de instructone • Manual de instrucci ones • Gebruiksaanwi jzing  Ɋɍ Ʉ ɈȼɈȾ ɋ Ɍ ȼɈ  ɉɈ  ɗɄ ɋɉɅɍ Ⱥ Ɍ Ⱥɐɂɂ EN FR DE IT ES NL     [...]

  • Page 2

    2 Content s Introduction .......... ....... ............ ............. ....... ............. ............. ... 3 Important Safety Information ........ ............. ...... ............. .......... 4 1. Overvi ew .... ............. ............ ....... ............. ............. ...... .......... 5 2. How to Obtain Meaningful Rea dings .... .......[...]

  • Page 3

    3 EN Intr oduction The O MRON M6 is a c ompac t, full y aut omatic blood press ure moni tor , operat ing on the os cill ometr ic pr incip le. It meas ures y our blood press ure a nd pul se rate si mply and qui ck ly . F or com f or table c ontrolle d infl ation wi thout th e need of p ressure pr e-se tting or r e-i nflatio n the devices us es i ts [...]

  • Page 4

    4 Impor tant Safety I nf ormation • Blood pres sur e meas ureme nt is not suitable i n cas es of ser i - ous ar ter io scl eros is (har denin g of the ar te ri es). • The p uls e dis pla y is not su ita b le f or mo nitor in g the fr equen cy of car diac pace makers. • Preg nant wom en sh ould on ly me asur e their own blood pres- sure in co [...]

  • Page 5

    5 1.Ove rview EN 1. Ov er view Monitor A. Displa y B . O/I ST AR T butt on C. M e m or y ( ) bu tt o n s D . Date/Ti me ( ) setting b utton E. Batter y co mpar tmen t F. A i r j a c k G. A C adapte r jac k (f or opti onal A C adapter) B D A C E G F[...]

  • Page 6

    6 1.Overview Displa y P ac kage contents H. Systo lic b lood pres su re I. Diasto lic b lood pres sure J . Mem or y di spl a y K. A v erage v a lue di spla y L. Mo v eme nt error dis pla y M. Irregul ar h ear tbeat di spla y N. Bat t er y low displ a y O . He ar tb eat disp lay P . Pu lse di sp la y Q. Def lat ion di spl a y R. Date/Time di spla y [...]

  • Page 7

    7 2.H ow to Obt ain Mea ning ful R eadi ngs EN 2. H o w to Obtain Mea ningful Readings T o help ensur e a reliab le reading, a v oid eatin g, smoking, or e x e rcising f or at least 30 min utes bef ore tak ing a me asure- men t. Note: Remov e a ny tight- fittin g clot hing fr om your uppe r ar m. 1. Si t on a chair with your f e et flat on the floo[...]

  • Page 8

    8 3.Prep aration 3. Pr ep ara tio n 3.1 Installing/Replacing the Batteries 1. Remove the batte r y cov er . 2. Ins er t f ou r “AA” batter i es as i ndi- cat ed in th e b atter y com par tmen t and then replac e the ba tter y cov er . No tes : • If the batter y low dis play ( ) appe ars o n the di sp la y , rep lace all four batte r ies at th[...]

  • Page 9

    9 3.Pr epara tion EN 3.2 Setting the Date and Time Y o ur blood pres sure m onitor autom atical ly s tores u p to 90 meas urem ent s v a lue s in its m emor y and calc ula tes an av erag e re ading b ased o n the m easur ements from the la st thr ee re ad- ings . • Se t the mon itor to the c orrec t date an d time bef ore t aking a measu remen t [...]

  • Page 10

    10 3.Prep aration 4. Repe at step s 2 and 3 t o set th e m onth and date ( da y). 5. Repe at step s 2 and 3 t o set th e h our and mi nutes for the tim e. 6. Pr ess the O/I ST A R T button w hen you ha ve finished s etting the date and tim e. or or or or[...]

  • Page 11

    11 4.U sin g the M onitor EN 4. Using the Monitor 4.1 Applyi ng the Arm Cuff Y o u can wrap the cuff either on your ri ght or left a r m. • Rem ov e tight-fit tin g clot hing fr om y our u pper ar m . • Do n ot plac e the c uff ov e r thi ck cloth es and do not ro ll up your sleev e if it is too tight. 1. If the cu ff is assem b led correc tly [...]

  • Page 12

    12 4.Using the Monitor 3. Si t in a c hair wi th y our f eet fl at on th e floor and p lace your ar m on a table so that the cuff wi ll be at the s ame l e vel as your hear t . 4. Put your ar m thr ough t he cuff lo op . The bo ttom of the cuf f s hould b e approximately 1 to 2 cm abov e the el bow . App ly the cuff to your upper a r m s o that the[...]

  • Page 13

    13 4.U sin g the M onitor EN 5. Pul l the cuff so that the top and bo t- tom e dge s ar e tighte ned e venly ar ound your ar m. 6. Whe n the c uff is pos itione d corre ctly , clos e the fabric fa ste ner FIRM L Y . No tes : • Make cer tai n the c uff fits snugly around your ar m . • The c uff shoul d make good con tact with y o ur skin. Y ou s[...]

  • Page 14

    14 4.Using the Monitor 4.2 T akin g a Rea ding 1. Pr ess the O/I ST A R T butt on and remai n stil l, the cu ff will star t to i nflate a utomati call y . As the cu ff begi ns to i nflate, the monitor autom atica ll y dete r- min es your ide al inf lation le v el. Rem ain s till and do not talk until meas urem ent is comp leted. No te: Do not infla[...]

  • Page 15

    15 4.U sin g the M onitor EN 4. Pres s the O /I ST AR T button t o tur n the m onitor off . No te: If y ou f or get to tu r n the mo ni- tor of f , it will au toma tical ly shut i tself off after fiv e mi nutes. Impo r tan t: • W ai t 2-3 minutes bef ore ta king another blood pres sure meas- ureme nt. W ai ting be tween rea din gs al lows the ar [...]

  • Page 16

    16 4.Using the Monitor What is Irregu lar Hear tbeat? An i rregul ar hear tb eat is a hear t beat r h yth m that varie s by more tha n 25% from the av erage hear tbe at rh ythm det ec ted whi le th e uni t is meas ur ing the sy stoli c and dia sto lic blood pres sure. If s uch an irr egular rh ythm is dete cte d more tha n tw ice du r- ing measu re[...]

  • Page 17

    17 4.U sin g the M onitor EN 4.3 Using the Memor y Functio n This monit or has a mem or y capa b l e of stor ing 9 0 sets of re ad- ing s. Ev e r y time you comp let e the me asur ement, t he m onitor auto mati call y sto re s blood pr essu re and pu lse rat e. The moni- tor also calc ulates an av erage r eadi ng bas ed on th e m easure- ment s f r[...]

  • Page 18

    18 4.Using the Monitor T o View Previous Readings S tored in Memor y 1. Pres s the b utton, while the a verage readin g is display ed, to v iew readin g stored in memor y from the mos t recen t to the olde st. 2. Pre ss the or button repea tedly to cy cle throug h the pr e vio us me asur ement values ( button: fr om th e mo st re cent to the ol des[...]

  • Page 19

    19 5.Hand li ng Errors and Pr oble ms EN 5. Handling Err ors and Pr oblems Err or Displa y Cause Remedy Cuff is unde r inflated. Carefully read an d repeat the steps listed under “T aking a Read- ing” on p . 14. Mov em ent during meas- urement Cuff o v er inflated. This ico n indicates irreg- ular or weak pulses are detected, b ut result can be[...]

  • Page 20

    20 6.Optiona l Parts 6. Optional P ar ts Probl em Cause Remedy No displa y appears when the O/I ST AR T but ton is pressed. The batteries are empt y . Replace the batteries. Cannot measur e or readings are too high. Is the cuff wrapped fir mly around the ar m? Attach th e ar m cuff cor- rectly . The cuff pressure does not r ise although the pump m [...]

  • Page 21

    21 7.Stora ge an d Mai ntena nce EN 7. Storage and Maintenance T o prot ect y our monito r from damage , please obser v e the fo l l o w i n g : • Do not subject y our monitor and cuff to e xtreme temperatures , humidity , moisture or direct sunl ight. • Do not f old the cuff or tubing tigh tly . • Do not disassemb le the monitor . • Do not[...]

  • Page 22

    22 8.Technica l Data 8. T e chnica l Data Note: Subj ect to te chnical modifi catio n with out prior no tice • This OMR ON produ ct is prod uced unde r t he strict qua lit y system of OMR ON Health- care Co . Ltd., J apan. The Co re component f or OMRON b lood pressure monito rs , which is t he Pressure Sensor , is produced i n Ja pan for a ssemb[...]

  • Page 23

    23 8.T echnical Data EN                 ![...]

  • Page 24

    24 9.Some Useful Infor mation abo ut Blood Pr essure 9. Some Useful I nf orm ation about Blood Pressure What is Blood Press ure? Bl ood pr essu re is a mea sure of th e force of blood fl owing agai nst th e walls of the ar ter i es. Ar ter ial blood pres sure is con- sta ntly c hangi ng dur i ng the c ourse o f the hear t's cy cle. Th e high e[...]

  • Page 25

    25 9.So me Usefu l Infor mation a bo ut Blood P ressu re EN Class ification of Blood Pressure by the W orld Heath Or ganizat ion The World H ealth O rga nizati on (WHO ) an d the Int er nati onal Soc iety of Hype r tensi on (ISH ) de v eloped the Blood Pre ssure Clas sifi catio n sh own in this figur e. Th is cla ssi ficati on i s based on the b lo[...]

  • Page 26

    26 9.Some Useful Infor mation abo ut Blood Pr essure        ;(<   < ( =6 )6(>)( [...]