Ingersoll-Rand PD10E-X-X manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PD10E-X-X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PD10E-X-X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PD10E-X-X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ingersoll-Rand PD10E-X-X should contain:
- informations concerning technical data of Ingersoll-Rand PD10E-X-X
- name of the manufacturer and a year of construction of the Ingersoll-Rand PD10E-X-X item
- rules of operation, control and maintenance of the Ingersoll-Rand PD10E-X-X item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PD10E-X-X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PD10E-X-X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PD10E-X-X.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PD10E-X-X item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INGERSOLL RAND COMP ANY L TD P .O . BOX 151  ONE ARO CENTER  BR Y AN, OHIO 43506-0151  (800) 276-4658  F AX (800) 266-7016 © 2009 CCN 15244940 OPERA T OR’ S MANU AL PD10E- X- X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 6-15-05 REVISED: 5-25-09 (REV . 03) 1” DIAPHRA GM PUMP 1:1 RA TIO ( CO NDUCTIVE NON- MET ALLI[...]

  • Page 2

    Page 2 of 8 PD10E-X -X (en) EX CESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not exc eed the maximum inlet air pressure as stated on the pump model plat e. Be sure material hoses and other components are able to withstand[...]

  • Page 3

    PD10E-X -X (en) Page 3 of 8 Page 3 of 8 GENERAL DESCRIPTION The ARO diaphragm pump oers high volume deliver y even at low air pr essure an d a broad rang e of material comp atibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / uid sections. Air operated double diaphragm[...]

  • Page 4

    Page 4 of 8 PD10E-X -X (en) FL UID SECTION SERVICE KITS (637396-X X)  KITS INCL UDE: BALLS (see Ball O ption, ref er to -X X in Service Kit char t below), DIAPHRAGMS (see Diaphr agm Option, refer to - XX in Service Kit char t below), and items 19, 33, 70, 144, 175 and 180 (listed below) plus 174 and 94276 L ubriplate F ML-2 gr ease (page 6). SEA[...]

  • Page 5

    PD10E-X -X (en) Page 5 of 8 Page 5 of 8 TORQU E REQUIREMENTS LUBRICA TION / SEALANTS Lubriplate FML-2 is a white food grade petroleum grease. cups & mating parts. Apply Loctite 242 to threads at assembly . Apply Lubriplate FML-2 grease to all “O" rings, ”U" Apply anti-seize compound to thread s and bolt and nut ange h eads w hi[...]

  • Page 6

    Page 6 of 8 PD10E-X -X (en) P ARTS LIST / PD10E-X -X AIR SECTION AIR MO T OR SEC TION SERVICE Ser vice is divided into two parts − 1. Pilot V alve, 2. Major V alve. GENERAL REASSEMBL Y NOTES: Air Motor Section Ser vice is continued from F luid Section repair . Inspec t and replac e old par ts with new parts as necessar y . Look for deep scrat che[...]

  • Page 7

    PD10E-X -X (en) Page 7 of 8 Page 7 of 8 TORQUE REQUIREMEN TS ALL F ASTENERS ARE METRIC. LUBRICA TION / SEALANTS Apply anti-seize compound to threads at assembly . Apply Lubriplate FML-2 grease to “O" rings, ”U" Cups & mating parts. NOTE: DO NOT OVERTIGHTEN F ASTENERS. T orque (105 and 134) screw to 35 - 40 in. lbs (4.0 - 4.5 Nm). [...]

  • Page 8

    Page 8 of 8 PD10E-X -X (en) PN 97999-1159 TROUBLE SHOO TING Product discharged from e xhaust outlet. Check for diaphrag m rupture. Check tightness of (6) diaphragm scr ew . Air bubbles in product discharge. Check connections of suction plumbing. Check“O” rings bet ween intake manifold and inlet side uid caps. Check tightness of (6) diaphragm[...]