Ingersoll-Rand PM20X-X-X-B02 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PM20X-X-X-B02, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PM20X-X-X-B02 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PM20X-X-X-B02. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ingersoll-Rand PM20X-X-X-B02 should contain:
- informations concerning technical data of Ingersoll-Rand PM20X-X-X-B02
- name of the manufacturer and a year of construction of the Ingersoll-Rand PM20X-X-X-B02 item
- rules of operation, control and maintenance of the Ingersoll-Rand PM20X-X-X-B02 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PM20X-X-X-B02 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PM20X-X-X-B02, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PM20X-X-X-B02.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PM20X-X-X-B02 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CCN 15227689 OPERA T OR’S MANUAL P M 2 0 X -X -X -B 0 2 RELEASED: 2-8-05 REVISED: 5-6-10 (REV . 03) INCLUDING: OPERA TION, INST ALLA TION & MAINTENANCE 2” DIAPHRAGM PUMP 1:1 RA TIO (MET ALLIC) READ THIS MANUAL CAREFULL Y BEFORE INST ALLING, OPERA TING OR SERVICING THIS EQUIPMENT . It is the responsibility of the employer to place this infor[...]

  • Page 2

    PM 20X -X-X -B0 2 Page 2 of 8 OPERA TING AND SAFETY PRECAUTIONS READ, UNDERST AND, AND FOLLOW THIS INFORMA TION TO A VOID INJURY AND PROPERTY DAMAGE. EXCESSIVE AIR PRESSURE ST A TIC SPARK HAZARDOUS MA TERIALS HAZARDOUS PRESSURE W ARNING EXCESSIVE AIR PRESSURE. Can cause person - al injury , pump damage or property damage. S Do not exceed the maximu[...]

  • Page 3

    Page 3 of 8 PM 20X -X-X -B0 2 GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibility options available. Refer to the model and option chart. ARO pumps feature stall resistant design, modular air motor / fluid sections. Air operated double diaphragm pumps utilize a [...]

  • Page 4

    NOTE: Seat options -AXX do not requir e item 19 “O” ring. MA TERIAL CODE [A] = Aluminum [B] = Nitrile [C] = Carbon Steel [Co] = Copper [E] = E.P .R. [SP] = Sant oprene [SS] = Stainless Steel [T] = PTFE PM 20X -X-X -B0 2 Page 4 of 8 P ARTS LIST / PM20X -X-X-B 02 FLUID SECTION FLUID SECTION SER VICE KITS (637309 - XX) L KITS INCLUDE: BALLS (See ?[...]

  • Page 5

    Page 5 of 8 PM 20X -X-X -B0 2 P ARTS LIST / PM20X -X-X-B 02 FLUID SECTION 1 k 26 ,G FOR THE AIR MOTOR SECTION SEE P AGES 6 & 7 43 68 60 (Santoprene) 87 (PTFE) 7 5 21 19 z k 180 131 , x 175 k 70 k 69 Figure 2 VIEW OF TWO PIECE PTFE DIAPHRAGM G. 27 22 70 k 6 14 , 9 144 k . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS [...]

  • Page 6

    PM 20X -X-X -B0 2 Page 6 of 8 P AR TS L IS T / PM 20X -X -X -B0 2 AI R SE CTI ON n Indicates parts included in 637421 Air Section Service Kit s hown below and items (70), (144), (175), (180) shown on page 4. AIR MOTOR P ARTS Item Description (size) Qty Part No. [Mtl] Item Description (size) Qty Part No. [Mtl] 101 Center Body (PM20A -X -X-B 02) (1) [...]

  • Page 7

    Page 7 of 8 PM 20X -X-X -B0 2 P AR TS L IS T / PM 20X -X -X -B0 2 AI R SE CTI ON 168 k 105 , . TORQUE REQUIREMENTS , NOTE: DO NOT OVERTIGHTEN F ASTENERS. ALL F ASTENERS ARE METRIC. T orque (105) Screw to 40 - 50 in. lbs (4. 5 - 5.6 Nm). T orque (134) Screw to 40 - 50 in. lbs (4. 5 - 5.6 Nm). T orque (240) Screw to 40 - 50 in. lbs (4. 5 - 5.6 Nm). L[...]

  • Page 8

    PM 20X -X-X -B0 2 Page 8 of 8 TROUBLE SHOOTING Product discharged from exhaust outlet. S Check for diaphragm rupture. S Check tightness of (14) diaphragm screw . Air bubbles in product discharge. S Check connections of suction plumbing. S Check “O” rings between intake manifold and inlet side fluid caps. S Check tightness of (14) diaphragm scre[...]