A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Honeywell 1EN2R-9005 0406R3-NE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Honeywell 1EN2R-9005 0406R3-NE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Honeywell 1EN2R-9005 0406R3-NE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Honeywell 1EN2R-9005 0406R3-NE should contain:
- informations concerning technical data of Honeywell 1EN2R-9005 0406R3-NE
- name of the manufacturer and a year of construction of the Honeywell 1EN2R-9005 0406R3-NE item
- rules of operation, control and maintenance of the Honeywell 1EN2R-9005 0406R3-NE item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Honeywell 1EN2R-9005 0406R3-NE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Honeywell 1EN2R-9005 0406R3-NE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Honeywell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Honeywell 1EN2R-9005 0406R3-NE.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Honeywell 1EN2R-9005 0406R3-NE item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PRODUCTION HANDBOOK 1 EN2R-9005 0406R3-NE Subject to change without notice. All rights reserved. L41../L61.. SERIES THERMOSTAT (AQUASTAT) APPLICATION The L41../L61.. series aquastats are pr imarily designed for application on water filled heating systems and systems f or hot water supply , mainly domestic use. Contents General page Description of d[...]

  • Page 2

    EN2R-9005 0406R3-NE 2 DESCRIPTION OF DEVICE FUNCTIONS Aquastats thermostats Honeywell man ufactures a coprehensiv e range of water temperature thermostats (trade name Aquastat) for controlling and limiting boiler water temper ature in hydronic heating systems. These sensitive , fa st response devices are a vailab le in either direct, panel or surf [...]

  • Page 3

    3 EN2R-9005 0406R3-NE DESCRIPTION The L41../L61.. series aquastats are sensitive w ater tempera- ture control, which are provided with a liquid filled sensing sys- tem. The f ollowing main types are av ailable: • Single, panel mount immersion Aquastat with remote bulb to select the most f avour able position on a boiler or vessel. • Single, dir[...]

  • Page 4

    EN2R-9005 0406R3-NE 4 OV ER VIEW/SELECTION GUIDE Application Single Aquastat thermostats Dual Aquastat thermostats Controller or limiter thermostat Controller and limiter thermostat with standard sensing element Direct mount (immersion) L4188A, B, C 25 ... 95°C 40 ... 110°C 70 ... 140°C L6188A, B, C 25 ... 95°C 40 ... 110°C 70 ... 140°C L4191[...]

  • Page 5

    5 EN2R-9005 0406R3-NE FEATURES • 6.3 mm quick connect terminals for receptacles • Mounting either in a horizontal or ve r tical position. • Housing is provided with two mounting holes which are suitable f or M4 thread forming screws, f or mounting on a control panel. • Cable entry in the conduit box is suitab le for Pg 13.5 conduit or is pr[...]

  • Page 6

    EN2R-9005 0406R3-NE 6 L4188 - L6188 SINGLE AQUASTAT - DIRECT IMMERSION APPLICATIONS AND OR DERING INFORMATION Application L4188 and L6188 are sensitive , immersion-type water temperature thermostats for controlling and limiting boiler water temperature in h ydronic heating systems. The thermostat has a liquid-filled sensing element which fits into [...]

  • Page 7

    7 EN2R-9005 0406R3-NE L4188 - L6188 SINGLE AQUASTAT - DIRECT IMMERSION Specifications Ambient temperature limits 0 ... 70°C Electrical connection 6.3 mm spade terminals Enclosure IP40 Electrical rating 10 A at 250 V ac, resistiv e load 2.5 A at 250 V ac, inductiv e load 15 A at 250 V ac, loc ked motor 250 mA at 30 mVdc (special option) Te r m i n [...]

  • Page 8

    EN2R-9005 0406R3-NE 8 L4189 - L6189 SINGLE AQUASTAT - PANEL MOUNTING (IMMERSION) APPLICATIONS AND ORDERING INF ORMATION Application L4189 and L6189 are sensitive , immersion-type water temperature thermostats for controlling and limiting boiler water temperature in h ydronic heating systems. These thermostats are designed for panel mounting and are[...]

  • Page 9

    9 EN2R-9005 0406R3-NE L4189 - L6189 SINGLE AQUASTAT - PANEL MOUNTING (IMMERSION) SPECIFICATIONS AND DIMENSIONS Specifications Ambient temperature limits 0 ... 70 ° C Electrical connections 6.3 mm spade terminals Enclosure IP40 Electrical rating 10 A at 250 V ac, resistiv e load 2,5 A at 250 V ac, inductiv e load 15 A at 250 V ac, loc ked motor 250[...]

  • Page 10

    EN2R-9005 0406R3-NE 10 L6190 SINGLE AQUASTAT - SURFACE MOUNTING APPLICATION AND OR DERING INFORMATION Application The L6190 is a sensitive w ater temperature thermostat designed f or surface mounting on domestic hot wa ter cylinders or pipe work. The SPDT switching action is accomplished b y a snap-action micros witch actuated by the temperature se[...]

  • Page 11

    11 EN2R-9005 0406R3-NE L6190 SINGLE AQUASTAT - SURFACE MOUNTING SPECIFICATIONS AND DIMENSIONS Specifications Ambient temperature limits 0 ... 70 ° C Electrical connection 6.3 mm spade terminals or screw ter minals Enclosure IP40 Electrical rating 10 A at 250 V ac, resistiv e load 2,5 A at 250 V ac, inductiv e load 15 A at 250 V ac, loc ked motor T[...]

  • Page 12

    EN2R-9005 0406R3-NE 12 L4191 - L6191 DUAL AQUASTAT - DIRECT IMMERSION APPLICATION AND ORDERING INF ORMATION Application L4191 and L6191 are dual units in which two independently working water temperature thermostats are housed in one cov er . Each ther mostat has a separate liquid filled sensing element which fits into a common immersion well f or [...]

  • Page 13

    13 EN2R-9005 0406R3-NE L4191 - L6191 DUAL AQUASTAT - DIRECT IMMERSION SPECIFICATIONS AND DIMENSIONS Specifications Ambient temperature limits 0 ... 70 ° C Electrical connection 6.3 mm spade terminals Enclosure IP40 Electrical rating: 10 A at 250 V ac, resistiv e load 2,5 A at 250 V ac, inductiv e load 15 A at 250 V ac, loc ked motor 250 mA at 30 m[...]

  • Page 14

    EN2R-9005 0406R3-NE 14 L6188A 2044 T RADELINE SINGLE AQUASTAT - DIRECT IMMERSION APPLICATIONS AND ORDERING INF ORMATION Application L6188A 2044 T radeline Aquastat is a sensitiv e immersion-type water temperature thermostat for regulating and limiting boiler water temperature in h ydronic heating systems. The Honeywell T radeline technique of using[...]

  • Page 15

    15 EN2R-9005 0406R3-NE L6188A 2044 T RADELINE SINGLE AQUASTAT - DIRECT IMMERSION SPECIFICATIONS AND DIMENSIONS Specifications T emperature rang e 40 ... 110 ° C Differential 4 ... 10 (adjustable) Limit stops: Low limit: adjustab le, f actor y set at 50 ° C High limit: adjustable , factory set at 95 ° C Ambient temperature limits 0 ... 70 ° C El[...]

  • Page 16

    EN2R-9005 0406R3-NE 16 PERFORMANCE Fixed switch differential On controls and recycling limits a fix ed differential of: 4 ± 1.5 ° C, 8 ± 3 ° C or 12 ± 3 ° C is supllied as a standard. Optional are: 7 ± 2.7 ° F, 14 ± 5.4 ° F 15 ± 5.4 ° F Adjustable switch diff erential On controllers and recycling limiters an adjustable diff erential of:[...]

  • Page 17

    17 EN2R-9005 0406R3-NE CONSTRUCTION All aquastats have the follo wing common parts • Thermoplastic housing of mainly rectangular form. This housing is the carrier of the Micro Switch mechanism, the 6.3 mm quick connect terminals, the le ver mechanism and the adjusting mechanism. • Thermoplastic switch cov er, which protects the s witch mechanis[...]

  • Page 18

    EN2R-9005 0406R3-NE 18 ACCESSORIES AND SPARE PAR TS Single well assembly Dual well assembly Description Ordernumber Pac king qty (pcs) Spud thread: 1 / 2 ” BSPT Maximum insertion length (including thread): 105 mm Suitable f or Ø 5 mm sensor 45.900.409-003 40 Spud thread: 1 / 2 ” BSPT Maximum insertion length (including thread): 170 mm Suitable[...]

  • Page 19

    19 EN2R-9005 0406R3-NE Miscellaneous Description Ordern umber Pac king qty (pcs) Knob assembly Scale range: 110 ... 230 ° F, high limit stop: 180 ° F 45.900.427-002 200 Knob assembly Scale range: 40 ... 110 ° C , high limit stop: 82 ° C 45.900.427-003 200 Strap set f or L6190 surface mounted aqustat Strap length: 2000 mm 45.900.443-001 50 Key n[...]

  • Page 20

    EN2R-9005 0406R3-NE 20 QUALITY ASSURANCE STATEMENT Products are manuf actured under an ISO 9001 (1994) based and cer tified Quality System. The quality system is described in the Honeywell Comb ustion Controls Center Quality Assurance Progr amme and its related operational procedures and instructions. The quality system is approv ed by Gastec again[...]

  • Page 21

    21 EN2R-9005 0406R3-NE OR DERING INFORMATION When ordering specify • Setting point(control and limit if necessary ) • T ype of contact (SPDT/SPST/ electr ical rating) • Number of sensing point (single/dual) • T ype of mounting (direct immersion/panel/surface) • Diff erential (adjustable/fix ed/manual reset) • Capillar y length Fig. 11. [...]