Heatcraft Refrigeration Products CC-HTSTB manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heatcraft Refrigeration Products CC-HTSTB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heatcraft Refrigeration Products CC-HTSTB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heatcraft Refrigeration Products CC-HTSTB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heatcraft Refrigeration Products CC-HTSTB should contain:
- informations concerning technical data of Heatcraft Refrigeration Products CC-HTSTB
- name of the manufacturer and a year of construction of the Heatcraft Refrigeration Products CC-HTSTB item
- rules of operation, control and maintenance of the Heatcraft Refrigeration Products CC-HTSTB item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heatcraft Refrigeration Products CC-HTSTB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heatcraft Refrigeration Products CC-HTSTB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heatcraft Refrigeration Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heatcraft Refrigeration Products CC-HTSTB.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heatcraft Refrigeration Products CC-HTSTB item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    C L I M A T E C O N T R O L C CHTSTB March 2011 Replaces C C-HTSTB, Dec 2008 www .cold y oucancounton.com A I R C O O L E D C O N D E N S I N G U NI T 1 / 2 T O 6 H P I ND OO R A ND O UT DO O R M O DE L S T echnic al Guide[...]

  • Page 2

    2 C H T 030 L 6 C F M odel C ompressor A pplication E quiv . HP T emp . R efrigerant V oltage I dentier C = Climate Control H = Hermetic S = Semi–herm. Z = Scroll T = Outdoor N = Indoor S = Beacon II™ Microprocessor 005 = 1/2 HP 008/009 = 3/4 HP 010, 011 = 1 HP 01* = 1–1/2 HP 02* = 2 HP 03* = 3 HP 04* = 4 HP 05* = 5 HP 060 = 6 HP H = High [...]

  • Page 3

    3 F eatures & Benets Typic al Outdoor Hermetic Unit Typic al Outdoor Unit with throwaw ay liquid-line lter and sight glass Typic al Outdoor Hermetic Unit with liquid lter drier and sight glass Cabinet & C onstruction • HyperCore ™ microc hanne l coi l techn ology standard on a ll uni ts • Pa int ed steel cabinets for s uperio[...]

  • Page 4

    4 Options Electric al options: Outdoor Indoor Stock Adjustable low pr essure contr ol for medium temp . comp . Option Option N/A Air or electric defrost timer only Option Option 1/2-3 HP low temp . Beacon II™ Option N/A N/A Crankcase heater Standard N/A Standard Dual pressure con trol (not available on Beacon II™) Option Option N/A Electric def[...]

  • Page 5

    5 HERMETIC COMPRESSORS P erformance Data - High T emperature (R-404A/507) R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 40°F 35°F CH*005H6 RST45C1E 8,910 8,150 CH*009H6 RST64C1E 12,520 11,570 CH*010H6 † RS70C1E 13,720 12,610 CH*015H6 CS10K6E 21,400 19,460 CH*025H6 CS14K6E 26,320 24,270 CH*032H6 CS20K6E 42,890 [...]

  • Page 6

    6 HERMETIC COMPRESSORS P erformance Data - Extended T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ † = RS compressor not suitable for R-507 R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 30°F 25°F 20°F 0°F -10°F -20°F -25°F CH*005X6 RST45C1E 6,850 6,270 5,710 3,690 2,810 1,9[...]

  • Page 7

    7 HERMETIC COMPRESSORS P erformance Data - Lo w T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 0°F -5°F -10°F -20°F -25°F -30°F CH*011L6 CF04K6E 7,030 6,240 5,370 3,850 3,330 2,630 CH*014L6 CF06K6E 10,500 9,380 7,830 6,090 4,890 4,[...]

  • Page 8

    8 HERMETIC COMPRESSORS P erformance Data - Medium & High T emperature (R-22) * = T for Outdoor, N for Indoor , S for Beacon II™ Hermetic C ompressors R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 40°F 30°F 25°F 20°F 15°F 10°F 0°F CH*005H2 ART82C1 7,470 5,640 5,090 4,610 4,170 3,740 2,940 CH*008H2 RS64C2 10[...]

  • Page 9

    9 HERMETIC COMPRESSORS Unit Specications Electrical Data Model Fig . ++ Compressor Connections (ID) Receiver 90% F ull Lbs. F an(s) Dimensions Net Wt. Lbs. Sound Data dBA † Liquid Suction D (In.) W (In.) H (In.) CH*005H2 A AR T82C1 3/8 1/2 6.0 1 28-1/4 23-3/4 17-1/4 135 67 CH*008H2 A RS64C2 3/8 1/2 6.0 1 28-1/4 23-3/4 17-1/4 141 68 CH*010H2 A [...]

  • Page 10

    10 Model Number Part Number Po wer Supply C ompressor Fan Motor MCA MOPD Evap . F an Amps Defrost Heater Amps V olts Ph Hz † RLA LRA Qty . HP FLA Air Elec. Air Elec. CH*040H2B CR53KQ-PFV 208-230 1 60 26.0 140.0 1 1/3 3.5 36.0 48.0 50 60 12.0 35 CH*040H2C CR53KQ- TF5 208-230 3 60 16.3 107.0 1 1/3 3.5 23.9 38.0 40 50 12.0 30 CH*040H2D CR53K Q- TFD [...]

  • Page 11

    11 * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 40°F 35°F 30°F 25°F 20°F 10°F 0°F -5°F CZ*020M6 ZS15K4E 24,810 22,630 21,160 19,690 18,210 15,340 12,640 11,390 CZ*025M6 ZS19K4E 29,280 26,730 25,070 23,390 21,700 18,380 15,230 13,750 CZ*030M6 ZS21K4E 35,[...]

  • Page 12

    12 * = T for Outdoor, N for Indoor , S for Beacon II™ NOTE: The ZF c ompressor comes with liquid injection. R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 0°F -10°F -15°F -20°F -25°F -30°F -40°F CZ*020L6 ZF06K4E 11,970 9,920 8,940 8,010 7,130 6,310 4,900 CZ*025L6 ZF08K4E 14,880 12,320 11,120 9,960 8,890 7,[...]

  • Page 13

    13 * = T for Outdoor, N for Indoor , S for Beacon II™ R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 35°F 30°F 25°F 20°F 10°F CZ*020M6 ZS15K4E 22,080 20,420 18,800 17,220 14,260 CZ*025M6 ZS19K4E 26,080 24,190 22,340 20,530 17,090 CZ*030M6 ZS21K4E 31,970 29,490 27,080 24,750 20,360 CZ*035M6 ZS26K4E 38,930 35,820 3[...]

  • Page 14

    14 R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 0°F -10°F -15°F -20°F -25°F -30°F -40°F CZ*020L6 ZF06K4E 11,610 9,400 8,380 7,450 6,590 5,840 4,590 CZ*025L6 ZF08K4E 14,560 11,800 10,540 9,380 8,310 7,340 5,780 CZ*030L6 ZF09K4E 15,940 13,070 11,750 10,500 9,340 8,260 6,460 CZ*035L6 ZF11K4E 19,310 15,870 14,270 1[...]

  • Page 15

    15 * = T for Outdoor, N for Indoor , S for Beacon II™ Per UL and NEC, RLA values hav e been calculated by dividing the Maximum Contin uous Current (MC C ) by 1.56. ^ Pow er supplied by customer . † Consult factory for 50 HZ applications . * = T for Outdoor, N for Indoor , S for Beacon II™ ++ = See Dimensional Drawings for details. † = Estim[...]

  • Page 16

    16 SEMI-HERMETIC COMPRESSORS P erformance Data - Medium T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 25°F 20°F 15°F 10°F 5°F 0°F -5°F CS*005M6 HAJ-005E 5,420 4,960 4,440 3,930 3,460 3,060 2,690 CS*010M6 KAR-010E 9,680 8,730 7,93[...]

  • Page 17

    17 SEMI-HERMETIC COMPRESSORS P erformance Data - Lo w T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ ^ NRD1-040E Compressor is Single Phase & uses R -404A only. ^^ Uses R-404A & 507 in 3 phase model. R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 0°F -5°F -10°F -20°F -25?[...]

  • Page 18

    18 SEMI-HERMETIC COMPRESSORS P erformance Data - Medium and High T emperature (R-22) * = T for Outdoor, N for Indoor , S for Beacon II™ R-22 Mo del Compr essor Capacity BTUH @ 95°F Ambient Suc tion T emperature 40°F 30°F 25°F 20°F 10°F 0°F CS*005H2 HAG-0050 5,630 4,710 4,280 3,640 2,830 – CS*008H2 KAN-0075 8,840 7,310 6,630 5,990 4,430 ?[...]

  • Page 19

    19 SEMI-HERMETIC COMPRESSORS Unit Specications * = T for Outdoor, N for Indoor , S for Beacon II™ ++ = See Dimensional Drawings for details. † = Estimated sound pressure v alues are 10 feet from the unit. F or estimating sound pressure from the unit at dierent distances, deduct the follo wing from the unit values: 20 feet, deduct 6 dBA fo[...]

  • Page 20

    20 SEMI-HERMETIC COMPRESSORS Electrical Data - Medium and High T emperature * = T for Outdoor, N for Indoor , S for Beacon II™ ^ Pow er supplied by customer . † Consult factory for 50 HZ applications. Model Number Part Number Pow er Supply Compr essor Fan Motor MC A MOPD Evap . F an Amps Defrost Heater Amps V olts Ph Hz † RLA LRA Qty. HP FLA [...]

  • Page 21

    21 SEMI-HERMETIC COMPRESSORS Electrical Data - Low T emperature * = T for Outdoor, N for Indoor , S for Beacon II™ ^ Pow er supplied by customer . † Consult factory for 50 HZ applications. NOTE: P er UL and NEC, RLA values have been c alculated by dividing the Maximum Continuous Current (MC C ) by 1.56 Model Number Part Number Power Supply Comp[...]

  • Page 22

    22 Dimensional Dra wings of Cabinets OUTDOOR A B C D 1/2, 3/4 AND 1HP 1-1/2 AND 2HP 3HP - AL TERNA TE CABINET 3, 4, 5 AND 6HP AIR FLOW AIR FLOW AIR FLOW AIR FLOW SUCTION LIQUID LIQUID SUCTION LIQUID LIQUID SUCTION FRONT VIE W OUTDOOR INDOOR FRONT VIE W POWER CONNECTIONS: (1) 7/8 & (1) 1-1/8 POWER CONNECTIONS: (1) 7/8 & (1) 1-1/8 POWER CONNE[...]

  • Page 23

    23 A B C D INDOOR 1/2, 3/4 AND 1HP 1-1/2 AND 2HP 3HP - AL TERNA TE CABINET 3, 4, 5 AND 6HP AIR FLOW AIR FLOW AIR FLOW AIR FLOW SUCTION LIQUID LIQUID SUCTION LIQUID LIQUID SUCTION FRONT VIE W OUTDOOR INDOOR FRONT VIE W POWER CONNECTIONS: (1) 7/8 & (1) 1-1/8 POWER CONNECTIONS: (1) 7/8 & (1) 1-1/8 POWER CONNECTIONS: (2) 7/8, (1) 1-3/8 & (1[...]

  • Page 24

    A Brand of Heatcraft Refrigeration P roducts, LL C 2175 West P ar k Place Blv d. • Stone Mountain, GA • 30087 (800) 321-1881 ww w .heatcraftrpd.com C L I M A T E C O N T R O L Cold Y ou Can Count On Since produ ct improvem ent is a continuing eo rt, we rese rve the ri ght to make change s in specicati ons without noti ce. F or more inf or[...]