Heatcraft Refrigeration Products H-IM-77D manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Heatcraft Refrigeration Products H-IM-77D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Heatcraft Refrigeration Products H-IM-77D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Heatcraft Refrigeration Products H-IM-77D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Heatcraft Refrigeration Products H-IM-77D should contain:
- informations concerning technical data of Heatcraft Refrigeration Products H-IM-77D
- name of the manufacturer and a year of construction of the Heatcraft Refrigeration Products H-IM-77D item
- rules of operation, control and maintenance of the Heatcraft Refrigeration Products H-IM-77D item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Heatcraft Refrigeration Products H-IM-77D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Heatcraft Refrigeration Products H-IM-77D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Heatcraft Refrigeration Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Heatcraft Refrigeration Products H-IM-77D.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Heatcraft Refrigeration Products H-IM-77D item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation and Operation Manual Reach-In Unit C oolers H-IM-77D June, 2006 Part No . 25005601 T able of C ontents Inspection ................................................................................. 2 Installation ................................................................................ 2 Expansion Valv e ..........................[...]

  • Page 2

    2 Inspection When the equipment is receiv ed, all items should be carefully checked against the bill of lading to make sure all crates and cartons have been r eceived. All units should be carefully inspected for hidden damage when rec eived. If any damage is found, it should be r eported to the carrier immediately and a claim should be led. The [...]

  • Page 3

     Description All Sizes Part Number 115V Motor 2500701 208/20V Motor 2500801 Fan Blade 5101B Fan Guard 5054D Motor Mount 91179001 Thin Profile Air Defrost Unit Cooler Mounting The thin profile air defrost unit cooler is designed for mounting from the top of the cooler . Drill holes f or screws in accor dance with moun ting dimensions A a[...]

  • Page 4

    4 Expansion Valve Recommendations -10°F . Suction 10° TD -15°F . Suction 15° TD M o d e l B T U H R - 4 0 4 B T U H R - 4 0 4 A Size 10° TD Alco Sporlan 15° TD Alco Sporlan 09 900 150 12 1200 HFS 1 / 8 SZ EFS 1 / 8 Z 1800 HFS 1 / 8 SZ EFS 1 / 8 Z 16 1600 2400 21 2100 150 HFS 1 / 4 SZ EFS 1 / 6 Z 28 2800 HFS 1 / 4 SZ EFS 1 / 6 Z 4200 HFS[...]

  • Page 5

    5 Motor Heater Model No. of Amps. Amps. Size Motors A* B* A* B* 09 1 0.8 0.4 4.1 2.07 12 2 1.6 0.8 5.22 2.61 16 2 1.6 0.8 6.09 .04 21 1 1.0 0.5 9.57 4.78 28  - 1.2 - 5.7 5 2 - 1.0 - 7.0 5  - 1.5 - 8.5 P a r t 115 Volt 208-230 V olt Description 09 12 16 21 09 12 16 21 28 35 53 Motor 2500701 2500701 2500701 250201 25?[...]

  • Page 6

    6 T ypical System Wiring Diagram with Thin Profile Electric Defrost Unit Cooler[...]

  • Page 7

    7 FOR FOOD SERVICE INST ALL A TIONS . . . seal any joint between unit cooler and cooler liner with a sealant listed by the National Sanitation Foundation, Standard 51 NOMENCL A TURE L T A 053 A A Vintage A = Air Defrost A = 115-1-60 L = Electric Defrost B = 208/20-1-60 S i z e Extended Thin Profile Unit Cooler Dimensional Diagram Extended Thin P[...]

  • Page 8

    8 Extended Thin Profile Unit Cooler (continued) Motor / F an Blade / Fan Guard Defrost Heater Cabinet Components Electrical Components Drain Fitting Mounting This unit cooler is designed for mounting from the top of the cooler . Dr ill holes for screws in accordanc e with mounting dimensions given in Dimensional Diagram and Data. After unpack ing t[...]

  • Page 9

    9 V Profile Unit Cooler Dimensional Diagram Mounting The V prole un it cooler is d esigne d for mo untin g from the top or t he back wall of the coo ler . Dril l hole s for screw s in acco rdance w ith mo unt- ing dimensions given in Dimensional Data. Afte r unpa ck ing t he uni t, se cure top of un it to ce ilin g or b ack wa ll an d ar rang e [...]

  • Page 10

    10 Dimensional Data Connections (In.) Approx. Model Dimensions (In.) Coil Ship Wt. No. A B C D W Inlet Suction Drain (Lbs.) 1 12 5 / 8 12  / 8 11 7 / 16 1  / 8 14 1 / 4  / 8 OD  / 8 ID 1 / 2 OD 16 17 15 5 / 8 12  / 8 14 7 / 16 1  / 8 17 1 / 4  / 8 OD 1 / 2 ID 1 / 2 OD 17 2 21 5 / 8 12  / 8 21 1 / 16 7 / 8 22  / 4 ?[...]

  • Page 11

    11 Standard or Connections (In.) Approx. Reverse Flow Dimensions (In.) Coil Shipping Models H L M W Inlet Suction Drain Wt. (Lbs.) 1 17  / 4 16 7 / 8 12 1 / 4 15 5 / 8  / 8 OD  / 8 OD 5 / 8 OD 19 17 19  / 4 16 7 / 8 14 1 / 4 15 5 / 8  / 8 OD  / 8 OD 5 / 8 OD 20 2 19  / 4 2 1 / 4 14 1 / 4 22  / 8 OD 1 / 2 OD 5 / 8 OD[...]

  • Page 12

    12 W all Mount Back Bar Unit Cooler Dimensional Diagram Mounting The Wall Mount Back Bar Unit Cooler is a lo w height unit designed for undercounter applications . Air is drawn in at the bottom of the unit and discharged out the front. T wo mounting angles are included with the unit and should be installed to space the unit 3/4” o the wall. Ai[...]

  • Page 13

    1 Air Defrost Wiring, Model BBM Electric Defrost Wiring, Model BBL[...]

  • Page 14

    14 Dual Aire Unit Cooler Recognized Component Underwriter’s Lab., Inc. FOR FOOD SERVICE INST ALL A TIONS . . . seal any joint between unit cooler and cooler liner with a sealant listed by the National Sanitation Foundation, Standard 51 Mounting 1. Dri ll h oles in ceiling or back wall and inser t #10 screws to within 1/16” of sur face. 2. Attac[...]

  • Page 15

    15 T win Approx. Flow Dimensions (In.) F an Ship Wt. Model A B C D E F G H J K L M Qty . Dia. (Lbs.) 09 16 1 / 8 19 1 / 8 7 9 / 16 4 2 5 / 16 9 9 / 16 2  / 4 4 7 / 8 4 1 / 2 8 5 / 8 2 1 / 2 2 5 / 8 1 5 1 / 2 ” 12 1 16 1 / 8 19 1 / 8 7 9 / 16 4 2 5 / 16 9 9 / 16 2  / 4 4 7 / 8 4 1 / 2 8 5 / 8 2 1 / 2 2 5 / 8 2 5 1 / 2 ” 14 18 16 1 / 8 1[...]

  • Page 16

    Since product improv ement is a continuing eort, we reserve the right to make changes in specications without notice . InterLink is your one-source supplier for a complete line of dependable and c ertied commercial refrigera tion parts, accessories and electronic controls. E ver y product is built to ensure the same high performance standa[...]