A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Elektra Beckum Cool 201, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Elektra Beckum Cool 201 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Elektra Beckum Cool 201. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Elektra Beckum Cool 201 should contain:
- informations concerning technical data of Elektra Beckum Cool 201
- name of the manufacturer and a year of construction of the Elektra Beckum Cool 201 item
- rules of operation, control and maintenance of the Elektra Beckum Cool 201 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Elektra Beckum Cool 201 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Elektra Beckum Cool 201, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Elektra Beckum service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Elektra Beckum Cool 201.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Elektra Beckum Cool 201 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operating Instruction Compressed Air-Dryer Cool 201 Cool 401 I14 5003 EGB 03.03[...]

  • Page 2

    2 03.03 T ype Code Cool 201 405AP Cool 401 407AP T ypes equipped with electromagnetic drainvalve according 2.6.1 and 3.8.1. (T ypes equipped with sensor oper ated drainvalve according 2.6.1, 3.8.2 and 5.1.6 are not available.) Serie V ersion[...]

  • Page 3

    3 11.02 T ype Code P art 1 Important user infor- mation P art 2 Installation P art 3 Description P art 4 Operation P art 5 Maintenance Appendix T ab le of contents All safety notes in this operating instruction which ma y cause harm to per sonnel or equipment, when ignored, are marked b y the f ollowing symbols: General danger symbol Electrical dan[...]

  • Page 4

    4 11.02 Part 1 Impor tant User Information 1.1 General notes • This compressed air-dr yer is called CA-dryer in the follo wing. • The Company does not accept responsibility if saf ety regulations are not met dur ing handling, operation, maintenance and repair , e ven though these are not str ictly stated in these operating instr uctions. • W [...]

  • Page 5

    5 11.02 ! ! P art 1 Important user Information Attention! The operator has to obser v e the national wor king-, op- er ating- and safety regulations . Also e xisting inter nal fac- tor y regulations must be met. Maintenance and repair wo rk must only be carried out b y specially trained personnel and, if necessary , under supervision of a person qu[...]

  • Page 6

    6 11.02 • W ear ey e protection and protectiv e glov es • A void contact of liquid refrigerants with your skin (frost- bite). • Do not inhale refrigerant vapours. • T o avoid higher concentrations , all wor k rooms must be ventilated v ery well. The opening of windows and doors may not be sufficient, so an e xhausting system must be used di[...]

  • Page 7

    7 11.02 ! P ar t 1 Important user Information • T ak e victim immediately into the fresh air or into a v er y well ventilated room. • Splashes of refr igerant in the e y es must be blo wn out with the mouth. Then r inse ey es with plenty of water . Do not wipe with cloth! • If the victim does not breathe, perf orm a mouth-to- mouth resuscitat[...]

  • Page 8

    8 11.02 2.1 T ranspor tation 2.2 Requirements on the place of in- stallation 2.3 Installation (mount ing) Fig. 1: Installation of CA-drye r Par t 2 Installation T ranspor tation has to be carried out in the nor mal oper- ating position of the CA-dr ye r . For a short time an inclined position of 45 ° is allowed. At the site of installation, the CA[...]

  • Page 9

    9 11.02 The cooling air f or the refriger ant condenser will be suck ed in at the front panel (fig. 5/3). This area must be kept free and not be obstructed. If necessar y , sufficient cooling air supply must be pro- vided by additional w all openings . The cooling air outlet is positioned at the top of the unit (fig. 5/8). Ensure a free air outlet [...]

  • Page 10

    10 11.02 Attention! A hose must be fix ed at the condensate drain and led out of the casing. An opening (Fig. 5/7) can be used for leading out the hose . F or saf ety reasons the side wall m ust be closed again. The CA-dr yer separates w ater as well as oil from the compressed air . The water/oil mixture must not be led into the sew age. W ater and[...]

  • Page 11

    11 11.02 2.6.3 Connection conden- sate draining Fig. 4: Connection conden- sate draining The condensate drain pipe (fig. 2.1) may be fix ed to the w all with a rising slope of maximum 5 m. Thereby the minimum operation pressure increases f or 0,1 bar per meter . The collecting pipe (fig. 2/2) should be laid through- out its whole length at least as[...]

  • Page 12

    12 11.02 3.1 Designation 3.2 Purpose 3.3 Unit Lay out Fig. 5: Complete system Fig. 6: Electronic regulator - operating panel Par t 3 Description Refr igerating compressed air-dryer (CA-dr yer). V ersion see type code (page 2) Compressed air will be dehumidified b y the CA-dr yer . F ollowing components of the CA-dr yer are accessible from outside ([...]

  • Page 13

    13 11.02 P art 3 Description 6 6 7 8 11 9 12 1 2 3 4 5 10 12 3.3.1 Symbols Fig. 7: Symbols gener al 3.3.2 electronic regulator symbols Fig. 8: Symbols electronic regulator Fig. 9: electronic regulator operation Operation switch “off ”. Compressed air inlet or outlet. Bef ore e xecuting maintenance work at the CA-dr y er , the unit must be disco[...]

  • Page 14

    14 11.02 3.4 electronic regulator Fig. 10: Nor mal displa y electronic regulator , e xample 3.4.1 Normal operation (factory setting) 3.4.2 Summer operation 3.4.3 A utomatic operation P art 3 Description The electronic regulator is a controller specially designed f or CA-dr yers. It operates on the basis of micro processors. Data as cooling temperat[...]

  • Page 15

    15 11.02 The nominal power of the CA-dryer mentioned in the technical data is related to a wo r king pressure of 7 bar , a compressed air inlet temperature of 35 °C as well as an ambient temperature of 25 °C acc. to DIN ISO 7183. Lo wer wor king pressure, higher compressed air inlet tem- perature and/or higher ambient temperatures o verload the c[...]

  • Page 16

    16 11.02 The refrigerant is injected into the refrigerant-to-air heat exchanger where it e v aporates, thereb y the compressed air is cooled. The electronic regulator regulates the cool- ing temperature and keeps the pressure de w point con- stant in nearly all capacity stages. The refr igerant compressed by the motor compressor is condensed within[...]

  • Page 17

    17 11.02 P ar t 4 Operation 4.1 Commissioning 4.2 Starting 4.3 Operation 4.4 Stopping After installation the CA-dr yer is supplied with pow er via the power cab le (fig. 5/1) or by operating the main s witch (fig. 5/13). Bef ore operating the operation s witch (fig. 3/14), a wait- ing period of at least 6 hours is absolutely necessar y . The CA-dr [...]

  • Page 18

    18 11.02 P ar t 4 Operation F ollowing operation data can be recalled b y operating the data selector k ey ( ): - Pressure dew point - Summer operation - P ercentage running time of CA-dr yer in relation to total running time of the system - Ne xt condensate drain in 3 min utes 1. Press data selector ke y ( ) f or 5 seconds to change from displa y-[...]

  • Page 19

    19 11.02 P ar t 4 Operation 4.6.1 Change modes 4.6.1.1 P01 4.6.1.2 P02 4.6.1.3 P03 4.6.1.4 P04 4.6.1.5 P05 4.6.1.6 P06 4.6.1.7 P07 4.6.1.8 P08 4.6.1.9 P09 4.6.1.10 P10 ! Activ ation pressure de w point-summer set value (f ac- tory setting: pressure de w point 7 °C). Ac knowledgement of f ailures (see 5.1) Ackno wledgement maintenance inter v al (s[...]

  • Page 20

    20 11.02 5.1 electronic regulator maintenance display Fig. 16: Maintenance displa y 5.1.1 Ac kno wledgement maintenance interval Fig. 17: A c knowledgement maintenance interval Par t 5 Maintenance Flashing maintenance symbol: - maintenance inter val e xceeded 1 . For ac knowledgement press data selector key ( ) within 5 minutes after restar t the C[...]

  • Page 21

    21 11.02 ! P ar t 5 Maintenance 5.1.4 W eekly maintenance 5.1.5 Cleaning of filter be- fore condensate drain with solenoid valve 5.1.5.1 Dismounting of filters Fig. 17: Solenoid valv e , ball valv e with filter 5.1.5.2 Mounting of Filters 5.1.6 Sensor controlled condensate drain (option) Inspection and cleaning of condensate draining system if nece[...]

  • Page 22

    22 11.02 P ar t 5 Maintenance 5.2 T roub le shooting Fig. 19: F ailure indication gener al 5.2.1 electronic regulator failure indication Fig. 20: electronic regulator F ailure indication Cause 5.2.1.1 F1 sensor pressure de wpoint def ectiv e 5.2.1.2 F2 sensor ambient temperature defectiv e 5.2.1.3 EH EEPR O M: electronic regulator 5.2.1.4 EL electr[...]

  • Page 23

    23 11.02 5.2.2 Ac knowledgement of failures Fig. 21: Ac knowledgement of f ailures 5.2.3 Function: Cause No function 5.2.4 W ater in compressed air system Cause 5.2.4.1 Condensate is not drained properly 5.2.4.2 electronic regulated condensate drain 5.2.4.2.1 F aulty condensate draining 5.2.4.2.2 Solenoid v alve de- f ective P ar t 5 Maintenance Re[...]

  • Page 24

    24 11.02 P ar t 5 Maintenance 5.2.4.3 Sensor-controlled condensate dra in 5.2.4.3.1 Bloc ked discharge pipe 5.2.4.3.2 Operation pressure below required mini- mum Cause 5.2.4.4 T emporar y o verload of the CA-dryer due to non-unif or m com- pressed air consump- tion 5.2.4.5 Ov er load due to high v olume flow , or too high compressed air inlet tempe[...]

  • Page 25

    25 11.02 P ar t 5 Maintenance 5.2.5 Stopping CA-dryer during operation: Cause - Stopping of CA-dr yer b y installed electr ic star t and protection de vice (Klixon) at the refrigerant compressor due to ov er load 5.2.5.1 CA-volume flow too high 5.2.5.2 CA-inlet temperature too high 5.2.5.3 Room temperature too high 5.2.5.4 Defectiv e fan or cooling[...]

  • Page 26

    26 11.02 P ar t 5 Maintenance 5.2.6 High differential pressure at CA-side: Cause 5.2.6.1 Compressed air v olume flow too high 5.2.6.2 W orking pressure too lo w 5.2.6.3 Icing of CA-dryer Remed y Check whether CA-dryer´s capacity is properly selected, increase CA-dryer´s capacity Increase operating pressure , check whether CA-dr yer´s capacity is[...]

  • Page 27

    Pos. Type-No. 405 AP 406 AP 407 AP m³/h 50 65 80 m³/min 0,83 1,08 1,33 2 m³/h 3 Power consumption (total) kW 0,25 0,27 0,33 4 Power consumption (fan) kW 5 50 Hz 6 Allowable pressure (compressed air) min./ max. bar 8 G 9 kg 40 41 44 height width depth 11 Refrigerant quantity R 134a kg 0,37 12 dB (A) 13 IP 14 G Pos.1 : +20°C 1 bar +35°C 7 bar +2[...]

  • Page 28

    operation switch Betr.-schalter 2 1 5 4 S1 M 1 (M200) Ventilator fan M2 M 1 Kälteverdichter fridge compressor (V100) 14 12 13 PE M1 K1 C1 10 11 A1 Kondensatablass condensate drain (A100) A1 A2 PE Y1 Regler Kälte-Drucklufttrockner L N 2 1 3 4 5 6 7 8 9 10 11 12 13 15 A2 NTC-Widerstand NTC-resistor R1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A B C D E F A B[...]

  • Page 29

    1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A B C D E F A B C D E F von Blatt Datum Bearb. Gepr. Norm Name Änderung Zustand Datum Urspr. Ers. f. DIN 40719 JN Typ: Zeichn.Nr./drawing no. L1.1 N1.1 M 1 (M200) Ventilator fan M2 Einspeisung durch Netzstecker supply by plug 220-230V1N~/50Hz L1 L1 PE N PE N X0 L XM + RAH = 1 Kondensatablass condensate drain (A100) [...]

  • Page 30

    A100 Y1 1 Pcs. Condensate Drain Solenoid Valve 405AP-407AP 0101775000 A102 1 Pcs. Drain Valve with Filter 405AP-407AP 0111713000 S1 1 Pcs. Operation switch 405AP-407AP 0108673000 M200 M2 1 Pcs. Fan motor 405AP-407AP 0102404000 PS00 S2 1 Pcs. Fan pressostat 405AP-407AP 0103087000 EICA A2 1 Pcs. Elektronic regulator 405AP-407AP 0111822405 - ...407 Ty[...]

  • Page 31

    D DEUTSCH ENG ENGLISH KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Wir erklären in alleiniger Verantwortlichkeit, dass dieses Produkt mit den folgenden Normen übereinstimmt* gemäß den Bestimmungen der Richtlinien** We herewith declare in our sole repsonsibility that this product complies with the following standards* in accordance with the[...]