E&J 6110.4ZL manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of E&J 6110.4ZL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of E&J 6110.4ZL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of E&J 6110.4ZL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of E&J 6110.4ZL should contain:
- informations concerning technical data of E&J 6110.4ZL
- name of the manufacturer and a year of construction of the E&J 6110.4ZL item
- rules of operation, control and maintenance of the E&J 6110.4ZL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of E&J 6110.4ZL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of E&J 6110.4ZL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the E&J service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of E&J 6110.4ZL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the E&J 6110.4ZL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OPERATING MANUAL FOR AGRI-THERM II HANDHELD DIFFEREN TIAL THERMOMETER MODEL 6110.4ZL TEMPERATURE RANGE: -40°C to 100°C or -40°F to 212°F Physical Address: 1891 North Oracle ● Tucson, AZ 85705-6444 Mailing Address: P. O. Box 5276 ● Tucson, AZ 85703-0276 Telephone: (520) 792-4545 ● Fax (520) 792-4546 ● Toll Free: (800) 422-4342 E-mail: in[...]

  • Page 2

    2 TABLE OF CONTENTS CHAPTER INFORMATION PAGE 1 INTRODUCTION 3 1.1 Unpacking Your Infrared Thermometer 4 2 OPERATING INSTRUCTIONS 2.1 Battery Charging Procedure 5 2.2 Abbreviations on Rear Panel 5 2.3 Turning the AGRI-THERM II On 6 2.4 Emissivity Settings 6 2.5 Surface Temperature Measurement 6 2.6 Temperature Differential Measurement 6 2.7 Ambient [...]

  • Page 3

    CHAPTER 1 INTRODUCTION verest Interscience, Inc., offers the most sophisticated non-contact infrared thermometers on the m arket today. The new AGRI-THERM II Handheld Differential Infrared Thermometer (Mode l 6110.4ZL) is the culm ination of over thirty-eight years of research and development by our f ounder and President. These are revolutionary h[...]

  • Page 4

    1.1 UNPACKING YOUR AGRI-THERM II INFRARED THERMO METER hen you unpack your AGRI-THERM II Infrared Thermometer, please be sure the following items are enclosed : 1. 4 Your new Model 6110.4ZL AGRI-THERM II Infrared Thermometer 2. A Carrying Case W 3. A Battery Charger 4. A Signal Output Cord 5. A Certification of Calibration 6. An Operating Manual If[...]

  • Page 5

    CHAPTER 2 OPERATING INSTRUCTIONS 2.1 BATTERY CHAR GING PROCEDURE our AGRI-THERM II has been charged at the factory before shipment. However, you may want to charge it agai n overnight before extended use. To recharge the batteries in your AGRI-THERM II Infrared Thermometer, plug the plug on the end of the six-foot lead of the supplied battery charg[...]

  • Page 6

    2.3 TURNING THE INSTRUMENT ON imply move the toggle sw itch on the Rear Panel entitled “PWR” to On. The “PWR” switch is located on the le ft side of the Rear Panel. S 2.4 EMISSIVITY SETTINGS (Target Emission Efficiency in %) missivity Compensation is done by pushing the “plus” (+) or “minus” (-) buttons on the Rear Panel of the infr[...]

  • Page 7

    The following photograph shows where the “S EL,” “IR,” “DIFF,” and “AMB” buttons are located: 2.8 “DATA” OUTPUT He “DATA” output is on the upper right hand side of the face place of the AGRI- THERM II. The instrument is provided with a signal cord to c onnect to a data logger through this receptacle. No data is stored in the[...]

  • Page 8

    CHAPTER 3 THROUGH-THE-LENS (TTL) INTRA-OPTICAL LIGHT SIGHTING (Patent No. 4,494,881 ) 3.1 TTL SIGHTING ith the Everest Through-The-Lens (TTL) Intra-Optical Light Sighting System (Patent No. 4,494,881), an illum inated imag e of the infrared detector is projected directly through the infrar ed optics of the infrared temperature sensor, illuminating [...]

  • Page 9

    9 To focus an instrument that will be used in the field or out-of-doors, first set the instrument up in subdued lighting in a laborator y. There you will be able to see the light being emitted by the Lig ht Emitting Diode (LED) and dete rmine the distance to spot s ize ratio. Then, when you are in the field, you ca n determine the area being measur[...]

  • Page 10

    10 CHAPTER 4 SPECIFICATIONS 4.1 AGRI-THERM II (Model 6110.4 ZL) SPECIFICATIONS TEMPERATURE MEASUREMENT Scale Range: -40 ˚ C to 10 0 ˚ C o r -40 ˚ F to 212 ˚ F Resolution: 0.1 ˚ C or 0.1 ˚ F Accuracy: ±0.5 ˚ C or ±1.0 ˚ F Repeatability: ±0.1 ˚ C or ±0 .2 ˚ F Temperature: All Functions in ˚ C or ˚ F, co rresponding t o voltage out Noi[...]

  • Page 11

    CHAPTER 5 MAINTENANCE 5.1 GENERAL his AGRI-THERM II will be virtually maintenance free. I t is recommended, however, that the instrum ent be returned to the factory after 24 m onths for a calibration check and recalibration, if necessary. It is important that you return the original ba ttery charger with the instrument and to use this battery charg[...]

  • Page 12

    CHAPTER 6 ONE-YEAR LIMITED WARRANTY SERVICE INSTRUCTIONS verest Interscience warrants each instrument to be free of defects in material or workmanship for a period of one year from the date of shipment to the orig inal purchaser. When examination of the instrument reveals that the fault has not occurred because of misuse or abnormal conditions of o[...]

  • Page 13

    13 EVEREST INTERSCIENCE, INC. 1891 NORTH ORACLE ROAD TUCSON, AZ 85705-6444 USA Please include a letter explaining the difficulty that you are having with the instrum ent, or complete the RMA Form provided to you, when returning the instrument for repair. An RMA Form can be downloaded from our website: www. EVEREST Interscience.com . It is necessary[...]