ADT Security Services Safewatch Plus Enterpreneur Security Systems manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ADT Security Services Safewatch Plus Enterpreneur Security Systems, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ADT Security Services Safewatch Plus Enterpreneur Security Systems one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ADT Security Services Safewatch Plus Enterpreneur Security Systems. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ADT Security Services Safewatch Plus Enterpreneur Security Systems should contain:
- informations concerning technical data of ADT Security Services Safewatch Plus Enterpreneur Security Systems
- name of the manufacturer and a year of construction of the ADT Security Services Safewatch Plus Enterpreneur Security Systems item
- rules of operation, control and maintenance of the ADT Security Services Safewatch Plus Enterpreneur Security Systems item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ADT Security Services Safewatch Plus Enterpreneur Security Systems alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ADT Security Services Safewatch Plus Enterpreneur Security Systems, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ADT Security Services service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ADT Security Services Safewatch Plus Enterpreneur Security Systems.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ADT Security Services Safewatch Plus Enterpreneur Security Systems item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ADT-1090-INT 7/25/00 3:12 PM Page 1[...]

  • Page 2

    ADT-1090-INT 7/25/00 3:12 PM Page 2[...]

  • Page 3

    Table of Contents * System Reference ................................................. 2 Operating Your System ......................................... 3 ARMING ....................................................................................... 3 Arming The System Prior To Leaving ..................................... 3 Arming The System Witho[...]

  • Page 4

    Zone Identification Card Space is provided for recording the areas of protection which are ;“““““““““‘““““““““’ : lndlvldual Zone Status i Ready status If lighted, zone is not secure. i ; /flight& the system is ready to be armed. Chedc doors, windows, etc. If not Iighted, one or more zones are faulted. i ! [...]

  • Page 5

    Operating Your System ARMING Before the control can be armed, all of the intrusion zones must be secure as indicated by the green READY indicator. If the READY indicator is off, one or more zones are faulted. The indicator(s) corresponding to the faulted zone(s) will light. Use the pull out zone I.D. card on the control station to determine the are[...]

  • Page 6

    ;I Turning Off the lnterlor Zones and Entrance Delay Control station key 4 may be used to turn the interior zones off prior to arming. This will allow the system to alarm instantly if the entrance door is opened, while armed. 1. Press the 4 key and hold for three seconds. 2. When interior defined zones are turned off, the corresponding Zone indicat[...]

  • Page 7

    DISARMING Your system is programmed with one or more entrance delay zones which allow time to enter the premises without causing an alarm. Each delay door may be programmed with a different entry time. Be sure to check with your installer. Note: If your system has the “Interior Follower” feature enabled, all interior designated zones automatica[...]

  • Page 8

    ALARM CONDITIONS Whenever an alarm occurs, the ALARM indicator will light, the audible alarm will sound (if applicable), and the control wilI communicate with the central station (if this option was purchased). NOTE: If upon returning to the premises it 1s discovered that an alarm has occurred, DO NOT ENTER THE PREMISES. Leave immediately and go to[...]

  • Page 9

    THE EMERGENCY KEYPAD PANIC ALARMS Your system may have been purchased with up to three emergency keypad panic alarms. These may be used to activate an alarm in the event of a Fire, Hold-up, or other emergency condition, as programmed by your installer. Each alarm is activated by pressing the appropriate emergency panic key (located below the numeri[...]

  • Page 10

    SPECIAL FEATURES The CHIME mode allows audible monitoring of zones while the system is disarmed. When the CHIME mode is active, the control station sounder will beep whenever a perimeter burglar defined zone (door, window, etc.) indicator is opened. For example, the CHIME feature will cause the control station to beep two times whenever the front d[...]

  • Page 11

    The bypass key (#) is used to bypass selected zones in your system. A bypassed zone will NOT be capable of activating an alarm as it is temporarily removed from your system. Bypassing (also referred to as shunting) is most commonly used to allow free movement of an area (zone or group of zones) while arming the rest of the system or to temporarily [...]

  • Page 12

    Your system may utilize a conventional key switch for arming and disarming the system. Arming and disarming with a key switch is performed as follows: cl 1. 2. 3. 0 1. 2. Arming Verify that the BEADY light is on. Insert your key into the key switch and turn. Hold for one second and release. The red ARMED light will blink during the exit delay cycle[...]

  • Page 13

    Programming Certain features of your system are programmable through the control station. The programming mode is entered by pressing key 9 and holding for three seconds, then entering the Master User Code. Other programming functions may be possible that are not detailed in this section. Consult your security representative for a list of the user [...]

  • Page 14

    Determine your desired new User Code or Master User Code sequence. If you make an error while programming, press the “ * ” key five times and start over from step 1. WARNING: Pressing the “ # ” or l4 * ” key while programmlng a code may result In Improper code operation, therefore you MUST return to step 1 when an error Is made. 0 1. 2. 3[...]

  • Page 15

    An optional feature of your system allows you to assign a certain number of valid uses to User Code 6. After the code has been used the programmed amount of times, it automatically becomes disabled. This code may be assigned to a maintenance person, a maid, or anyone who you would like to be able to arm and disarm the system for a selected number o[...]

  • Page 16

    Notes[...]

  • Page 17

    The TEST mode commands the control station to beep continuously and light the corresponding zone indicator, each time a zone is violated. The zone indicator of each tested zone will remain lighted while each succeeding zone is tested. Testing can be performed only while the system is disarmed. Testing the system should be performed in both ELECTRIC[...]

  • Page 18

    FIRE DETECTION Your system may or may not include fire detection, depending upon what options were purchased, and the local codes and regulations for your area. Fire alarm systems are active 24 hours a day and cannot be turned off. A!! fire systems require regular testing and maintenance. Common household dust build-up in smoke detectors can cause [...]

  • Page 19

    Emergency Evacuation Plan Preparation and education are of prime importance in the prevention of fire. An emergency evacuation plan should be established BEFORE an emergency situation arises. Your system may or may not contain fire detection and notification equipment. Be sure to have your installer explain and that you fully understand exactly wha[...]

  • Page 20

    The purpose of heat and smoke detectors is to detect a fire in its earliest stages and sound an alarm, giving occupants more time to exit the premises before smoke reaches a dangerous level. Cl KNOW FIRE HAZARDS No detection device can protect life in all situations; therefore, safeguards should be taken to avoid such potentially dangerous situatio[...]

  • Page 21

    0 Smoke Detector Location Smoke detectors should be installed in accordance with theNational FireProtection Association (NFPA) Standard 74. The following is from NFPA 74: Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit includin[...]

  • Page 22

    Smoke Detector Placement 4 inches @lm) -_I NOTE: Allmae~~mmennts are to the closest edge of the dote&or A Smoke Detector should be located on each story. A Smoke Detector should be located between the sleeping area and the rest of the family living unit. l Indicates required smoke detector @ Indicates smoke detector is optional if door is not p[...]

  • Page 23

    Glossary Alarm Memory: A history of the alarm that last occurred. Arm: To turn the intrusion detection system on. Bypass: To temporarily remove a zone from operation. To Shunt a zone. Control Panel: The main system electronics housed in a metal enclosure. Control Station: The remote station used to enter instructions to the control panel such as to[...]

  • Page 24

    ADT-1090-INT 7/25/00 3:13 PM Page 12[...]

  • Page 25

    ADT-1090-INT 7/25/00 3:13 PM Page 12[...]

  • Page 26

    Notes 20[...]

  • Page 27

    FCC COMPLIANCE This equipment ganerates and uses radio frequency energy and lf nU installed and used properly, that !a. In strict accordance with the rtwnufacturer’s instructions, may catae interference to radio and teledslon raceptlon. lt has been type tested and found to corrpiy with the llmks for a Class B corrputlng devtce In acwtdance with t[...]

  • Page 28

    MOOSE Sentrol, Inc resen~es the rtght to change specifmtmns wthout notice tJ1991 Sentrol. Inc[...]