York MLCA-MLHA-07-24 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of York MLCA-MLHA-07-24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of York MLCA-MLHA-07-24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of York MLCA-MLHA-07-24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of York MLCA-MLHA-07-24 should contain:
- informations concerning technical data of York MLCA-MLHA-07-24
- name of the manufacturer and a year of construction of the York MLCA-MLHA-07-24 item
- rules of operation, control and maintenance of the York MLCA-MLHA-07-24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of York MLCA-MLHA-07-24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of York MLCA-MLHA-07-24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the York service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of York MLCA-MLHA-07-24.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the York MLCA-MLHA-07-24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation & Owner ’ s Manual MODELS MLCA-MLHA 07-24 MLCB-MLHB 07-24 MACC-MAHC 07-24 MINISPLIT HIGH W ALL AIR CONDITIONER EN035M80013-000 The units comply with one or more of the following marks - see unit for details. J199.pmd 31/03/2005, 9:52 PM 1[...]

  • Page 2

    CONTENTS Safety Precautions ..................................................... 3 Part Names ................................................................. 4 Manual Operation ....................................................... 5 How the air conditioner works .................................. 5 Optimal operation ...........................[...]

  • Page 3

    3 ENGLISH EN EXTENDED P ARTS 1. Refrigarant Pipe 2. Pipe i nsulation material (Polyethylene foam 9 mm thick) 3. Vinyl tape 4. Putty REQUIRED TOOLS 1. Screw driver 9. Manifold gauge 2. Hexagonal wrench 10. Gas leak detector 3. T orque wrench 11 . V acuum pump 4. Spanner 12. Pipe clamp 5. Reamer 13. Pipe cutter 6. Hole core drill 14. Flare tool set 7[...]

  • Page 4

    4 ENGLISH (C ) T E M P A U T O C O O L D R Y H E A T F A N H I G H M E D L O W M O D E F A N S P E E D T I M E R O N S L E E P O N /O F F T IM E R O F F A IR D IR E C T IO N R E S ET LO CK S E T T E M P E R A T U R E S W I N G LE D D ISP L A Y TU R BO 9 5 4 7 2 1 3 8 6 12 13 10 11 P ART NAMES CAUTIONS 1. If air conditioner is used outside of the ab[...]

  • Page 5

    5 ENGLISH EN MANUAL OPERA TION 1 Open and lift the front panel up to an angle at which it remains fixed with a clicking sound. 2 Press the button until the AUTO indicator is lit, the unit will work in forced AUTO mode. 3 Close the panel firmly to its original position. • Once you push the manual button, the operation mode is shifted in an order a[...]

  • Page 6

    6 ENGLISH OPTIMAL OPERA TION T o achieve optimal performance, Please note the following: • Adjust the air flow direction correctly so that it is not directed on people. • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. • Close doors and windows on COOL or HEA T modes, or per[...]

  • Page 7

    7 ENGLISH EN OUTDOOR UNIT PICTURES 540 525 225 75 404 88 700 458 5 35 250 88 33 60 261 60 82 80 540 527 245 5 420 128 780 48 10 45 548 115 90 266 272 298 285 290 530 110 62 590 750 MLDA-MLJA 07-09, MLDB-MLJB 07-09, MADC-MAJC 07 MLDA-MLJA 12-18, MLDB-MLJB 12, MADC-MAJC 09-12 MLDA-MLJA 24, MLDB-MLJB 24, MADC-MAJC 18-24 MLDB-MLJB 18 335 125 560.1 141.[...]

  • Page 8

    8 ENGLISH ø 65 mm Number Name of part Q’ty 1 Installation plate 1 2 Clip anchor 8 3 Self-tapping screw A ST3.9X25 8 Connecting pipe assembly P ARTS INST ALLA TION NOTES INDOOR UNIT INST ALLA TION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 9

    9 ENGLISH EN • Be careful when handling the sharp edge of the mounting plate. ■ Wiring • This indoor unit is ready for connection to the outdoor unit. • Never modify the unit by removing any of the safety guards or by passing any of the safety interlock swithces. • Connect the interconnecting cable correctly and connect the connecting cab[...]

  • Page 10

    10 ENGLISH ■ Indoor Unit Fixing • Thread the indoor unit piping and cable through the hole. • Hang the top of the unit onto the upper ridge of them in mounting plate. • Make sure that the unit is correctly hung in place by sliding it to the left, then to the right. • Press the bottom left and bottom right hand corners of the unit against [...]

  • Page 11

    11 ENGLISH EN T o this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, then wait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs and repeat this procedure until the needle no longer moves. - Open the service valves and top up the ref[...]

  • Page 12

    12 ENGLISH ■ Wiring Prepare the power source for exclusive with the air conditioner . The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which is shown on the model. • Perform the wiring with sufficient[...]

  • Page 13

    13 ENGLISH EN ■ Wiring Connection Models : 07-18 Indoor Outdoor Cooling only type Cooling & heating type Cooling only type Cooling & heating type Models : 24 Indoor Outdoor 1 2(N) 3 4 1 2(N) 3 4 1 2(N) 1 2(N) 3 4 T e S 1 2 (N) Cooling & heating type Cord clamp 1 2(N) 3 4 5 6 7 8 Terminal block of Outdoor unit 1 2(N) S L N T erminal bl[...]

  • Page 14

    14 ENGLISH ■ Electrical Work ■ Defrosting operation (A vailable for heating only) 1. Condition to start defrosting: Units will switch to defrosting mode when either of the following conditions is met. a . Unit has been running under T3<0 º C for 40 minutes and T3<-3 º C for 3 minutes. b . Unit has been running at high temperature protec[...]

  • Page 15

    15 ENGLISH EN MAINTENANCE ■ Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks. 1. Lift the indoor unit panel up to an angle until it stops with a clicking sound. 2. T ake hold of the handle of the air filter and lift it up slightly to take it out from the filter ho[...]

  • Page 16

    16 ENGLISH OPERA TION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner . Compressor protection • The compressor can ’ t restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEA T mode, when the indoor heat exchanger[...]

  • Page 17

    17 ENGLISH EN TROUBLE SHOOTING GUIDE Problem Probable cause Remedy A. The air conditioner does not run. 1. Power failure. 1. Wait for power resume. 2. Fuse blown or circuit breaker 2. Replace the fuse or reset the open. breaker . 3. V oltage is too low . 3. Find the cause and fix it. 4. Faulty contactor or relay . 4. Replace the faulty component. 5[...]

  • Page 18

    18 ENGLISH TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R22 ” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height mm Dimensi[...]

  • Page 19

    19 ENGLISH EN 111 1 1 TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R22 ” - 60 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height[...]

  • Page 20

    20 ENGLISH TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R407C ” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height mm Dimen[...]

  • Page 21

    21 ENGLISH EN TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R410A ” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height mm Di[...]

  • Page 22

    DECLARACI Ó N DE CONFORMIDAD CM Choi Shipping Manager The product complies with the harmonized European safety standards and harmonized EMC standards listed above. We have internal production control system that ensures compliance between the manufacturer products and the technical documentation. The product is CE mark. We declare under our sold r[...]