Xantrex APG-HPD manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Xantrex APG-HPD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Xantrex APG-HPD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Xantrex APG-HPD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Xantrex APG-HPD should contain:
- informations concerning technical data of Xantrex APG-HPD
- name of the manufacturer and a year of construction of the Xantrex APG-HPD item
- rules of operation, control and maintenance of the Xantrex APG-HPD item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Xantrex APG-HPD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Xantrex APG-HPD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Xantrex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Xantrex APG-HPD.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Xantrex APG-HPD item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operating Manual Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply APG-XT APG-HPD[...]

  • Page 2

    [...]

  • Page 3

    Operating Manual for Internal APG (Analog Programming) Interface for XT 60 Watt and HPD 300 Watt Series Programmable DC Power Supply[...]

  • Page 4

    ii Operating Manual for APG for XT/HPD Series Power Supply Limited W arranty What does this warranty cover and how long do es it last? This Limited W arranty is pro vided by Xantrex T echnology , Inc. (“Xantrex”) and covers defects in workmanship and materials in your Internal APG Inte rface card . This warranty lasts for a W arranty Period of [...]

  • Page 5

    Release 1.0 iii Direct returns may be performed accordi ng to the Xantrex Return Material Authorization Policy describ ed in your pr oduct manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantre x or check our website to see if your product can be repaired at one of these facilities. In any warrant[...]

  • Page 6

    iv Operating Manual for APG for XT/HPD Series Power Supply Disclaimer Product THIS LIMITED W ARRANTY IS THE SOLE AND EXCLUSIVE W ARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YO UR XANTREX PRODUCT AND IS, WHERE PERMIT TED BY LA W , IN LIEU OF ALL OTHER W ARRANT IES, CONDITIONS, GUARANTEES, REPRESENT A TIONS, OBLI GA TIONS AND LIABILITIES, EXPRES S[...]

  • Page 7

    Release 1.0 v Information WITHOUT LIMITING THE GENERA LITY OF THE FOREGOING, UNLESS SPECIFICALL Y AGREED T O BY IT IN WRI TING, XANTREX a. MAKES NO W ARRANTY AS TO THE ACCU RACY , SUFFICIENCY OR SUIT ABILITY OF ANY TECHNICAL OR O THER INFORMA TION PROVIDED IN MANUALS OR O THER DOCUMENT A TION PROVIDED BY IT IN CONNECTION WITH THE PRODUCT ; AND b. A[...]

  • Page 8

    vi Operating Manual for APG for XT/HPD Series Power Supply W arn ings and Cautions W arnings and cautions are de fined and fo rmatted in this manual as shown below . Power Supply Safety W ARNING Describes a potential hazard which could result in injury or death, or , a procedure which, if not performed correctly , could result in injury or death. ![...]

  • Page 9

    Release 1.0 vii About This Manual This manual is for the internal APG (Analog Programming) interface card for the XT and HPD Series DC out put power supplies. This manual provides you with descriptions and specifications, user options , and configuration i nstructions which enable you to m anage the power supply from an external source. This manual[...]

  • Page 10

    About This Manu al viii Operating Manual for APG for XT/HPD Series Power Supply[...]

  • Page 11

    Release 1.0 ix Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Features and Specificati ons Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Features . . . . . . . . . . . . [...]

  • Page 12

    Content s x Operating Manual for APG for XT/HPD Series Power Supply[...]

  • Page 13

    Release 1.0 11 Section 1. Features and S pecifications Description The Analog Programming (APG) Interface is an internal optio n card for analog programming of XT and HPD Series DC power supplies with a 0-10Vdc programming source o r a 0-10k Ω resistance. A 25-pin female DSUB connector on the unit's rear panel enables connections to the card[...]

  • Page 14

    Section 1. Features and Specifications Specifications 12 Operating Manual for APG for XT/HPD Series Power Supply[...]

  • Page 15

    Release 1.0 13 Section 2. Inst allation and Configuration Introduction W e usually install the APG interface in a power supply at the factory . Y our local distributor or service cente r can also inst all the interface, especially for use in a previously-purchase d supply already on site. Initial Inspection On first receiving yo ur unit, perform a [...]

  • Page 16

    Section 2. Inst allation and Configuration Configuring 14 Operating Manual for APG for XT/HPD Series Power Supply Configuring Configure and adjust the analog programming interface installed in your XT or HPD DC power supply as indicated in thi s section. The front panel LEDs indicate when V or I programming is selected (PGM), wh en TTL shutdown has[...]

  • Page 17

    Section 2. Inst allation and Configuration Configuring Release 1.0 15 Rear Panel Figure 2.2 XT/HPD Rear Panel with APG Interface Rear Panel Switch (S1) Default s T a ble 2.1 Rear Panel Switch S1 Default Settings Default: Local contro l (all swit ches OPEN). Setting Function S1-1 TTL Shutdown Logic Select (OPEN=negat ive logic, CLOS ED=positive logi[...]

  • Page 18

    Section 2. Inst allation and Configuration Rear Panel J5 Connector 16 Operating Manual for APG for XT/HPD Series Power Supply Rear Panel J5 Connector Make analog interface connections via the rear panel 25-pin female DSUB connector designated J5. T o provid e the lowest noise performan ce, we recommend you use shielded-twisted pair wiring for makin[...]

  • Page 19

    Section 2. Inst allation and Configuration Calibration Adjustment Release 1.0 17 Calibration Adjustment Y ou can access most calibration potentiome ters through the top of the unit, see Figure 2.3. The exceptions are V oltage Program OFFSET and RANGE which are on the unit's rear panel which c an be seen on Figure 2.2. Figure 2.3 APG Interface [...]

  • Page 20

    Section 2. Inst allation and Configuration Calibration Adjustment 18 Operating Manual for APG for XT/HPD Series Power Supply[...]

  • Page 21

    Release 1.0 19 Section 3. Operation Remote Programming Remote programming allows control of th e power supp ly's output voltage and/or current limit to shift from lo cal op eration at the front panel vo ltage and current controls to external analog input sources. As you vary the programming source, the power supply's output varies proport[...]

  • Page 22

    Section 3. Operation Remote Programming 20 Operating Manual for APG for XT/HPD Series Power Supply 3. V ary the external voltage from 0-10Vdc to cause the po wer supply output to vary from 0-100% of rated output voltage. Y ou may set the power su pply's output current limit using another source or th e front panel current li mit control. Note:[...]

  • Page 23

    Section 3. Operation Remote Programming Release 1.0 21 Programming Output Current with a 0-10k Resist ance 1. Select remote current programming by ex ternal resistance by moving the rear panel switch S1-3 (remote current program select) to the ON (closed) position. Or , connect J5 pin 8 (remote current pr ogram select) to J5 pin 6 (auxiliary ground[...]

  • Page 24

    Section 3. Operation Readback and Status Indicators 22 Operating Manual for APG for XT/HPD Series Power Supply Readback and St atus Indicato rs V oltage and Current Readback V olt age Rea dback • Connect a meter between J5 connector pin 19 (voltage readback) and either pin 4 or 5 (program return). Range: 0-10V = 0-100% full rated voltage ou tput [...]

  • Page 25

    Section 3. Operation Overvoltage Protection (OVP) Release 1.0 23 Overvolt age Protection (OVP) The OVP circuit is designed to protect the load in the event of a remote programming error , incorrect voltage control adjustment, or power supply failure. The protection circuit monitors the output and reduces the output voltag e and current to zero when[...]

  • Page 26

    Section 3. Operation TTL Shutdown 24 Operating Manual for APG for XT/HPD Series Power Supply TTL Shut down TTL Shutdown allows the output of the po wer supply to be disabl ed by a logic level signal. This input is op ticall y isolated from the power supply output and will withstand a highpot test po tential of 600V ac minimum. When TTL shutdown is [...]

  • Page 27

    Section 3. Operation T racking Release 1.0 25 T racking For tracking +/- outputs, use the following set-up: • Set slave unit rear panel switc h S1-5 (remote voltage program select) and switch S1-6 (tracking select ) to ON (closed). • Connect master return (J5 connector pins 12, 13, o r 24) to slave +OUT (J5 connector pins 10, 1 1, or 23). • C[...]

  • Page 28

    Section 3. Operation T racking 26 Operating Manual for APG for XT/HPD Series Power Supply[...]

  • Page 29

    [...]

  • Page 30

    Xantrex Technology Inc. 8999 Nelson W ay Burnaby , British Columbia Canada V5A 4B 5 604 422 85 95 T el 604 421 30 56 F a x 800 667 8422 T oll Free North America prg.info@xantrex.com www .xantre x.com TM-5A6H-01XN PRINTED IN CANADA[...]