Wolf Ventilation Hood manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Wolf Ventilation Hood, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Wolf Ventilation Hood one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Wolf Ventilation Hood. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Wolf Ventilation Hood should contain:
- informations concerning technical data of Wolf Ventilation Hood
- name of the manufacturer and a year of construction of the Wolf Ventilation Hood item
- rules of operation, control and maintenance of the Wolf Ventilation Hood item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Wolf Ventilation Hood alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Wolf Ventilation Hood, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Wolf service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Wolf Ventilation Hood.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Wolf Ventilation Hood item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    I NST ALLA TION I NSTR UCTIONS C OOKT OP V ENTILA TION H OODS[...]

  • Page 2

    As you follow these instructions, you will notice W ARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip- ment. There are two types of potential hazards that may occur during installation. Another footnote we would like to identify is IMPORT ANT NOTE: This highlights informa- tion t[...]

  • Page 3

    3 INST ALLA TION REQUIREMENTS IMPORT ANT NOTE: This installation must be completed by a qualified installer or W olf a uthorized service center technician. I nstaller: P lease read the entire Installation Instructions prior to installation. Save these instructions for the local inspector’ s refer- e nce, then leave them with the homeowner . Homeo[...]

  • Page 4

    O VERALL DIMENSIONS MODEL CTWH30 Overall Width 30" (762) O verall Height (excluding chimney) 6 7 / 8 " (175) O verall Height (including chimney) 3 0 1 / 2 " (775) Max Height (full extension) 48 1 / 2 " (1232) Overall Depth 21" (533) Shipping W eight (shell only) 85 lbs (39 kg) Dimensions may vary to + – 1 / 8 " (3). [...]

  • Page 5

    HOOD PLA CEMENT W olf cooktop wall and island hoods come with a telescopic chimney flue that allows you to r each a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available. R efer to page 12 for optional accessories. I nstallation of the cooktop wall or island h[...]

  • Page 6

    W ALL HOOD INST ALLA TION INST ALL DUCTWORK IMPORT ANT NOTE: Consult a qualified HV AC Engineer for specific ducting applications. Decide where the ductwork will run between the hood and the outside. A straight, short duct run will allow the hood to perform more efficiently . Limit the number of elbows and transitions to as few as possible. Long du[...]

  • Page 7

    7 INST ALLA TION INSTRUCTIONS W ALL HOOD INST ALLA TION ELECTRICAL REQUIREMENTS W olf cooktop wall hoods require a separate, grounded 110 / 120 V AC, 60 Hz power supply . The service should have its own 15 amp circuit b reaker . Locate the electrical supply with a minimum of 12" (305) of 120 V AC power cable within the shaded area shown in the[...]

  • Page 8

    CONNECT DUCTW ORK U se the screws and wall anchors provided to secure the upper brackets to the ceiling. Position the upper brackets based on the d imension of the telescopic chimney flue. Use an 8" (203) round metal duct to connect the duct collar on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Connec[...]

  • Page 9

    9 Dimensions in parentheses are in millimeters unless otherwise specified. INST ALLA TION INSTRUCTIONS ISLAND HOOD INST ALLA TION INST ALL DUCTWORK IMPORT ANT NOTE: Consult a qualified HV AC Engineer for specific ducting applications. Decide where the ductwork will run between the hood and the outside. A straight, short duct run will allow the hood[...]

  • Page 10

    10 W OLF COOKT OP VENTILA TION HOODS Secure the upper half of the support frame to the joists and cross framing with four screws p rovided with your hood. Make sure that the screws are driven into the center of the joists and framing for maximum strength. Ensure the c orrect orientation of the support frame. A djust the overall height of the suppor[...]

  • Page 11

    11 Dimensions in parentheses are in millimeters unless otherwise specified. INST ALLA TION INSTRUCTIONS ISLAND HOOD INST ALLA TION MOUNT HOOD T O SUPPOR T FRAME M ount the hood to the support frame by aligning the four weld screws on the hood to the four holes on the support frame. Use four n uts to secure the hood to the support frame. Refer to th[...]

  • Page 12

    12 Dimensions in parentheses are in millimeters unless otherwise specified. W OLF COOKT OP VENTILA TION HOODS A CCESSORIES Optional acces- sories are available through your Wolf dealer . T o obtain local dealer information, visit the Locator section of our website, wolfappliance.com. VENTILA TION HOOD ACCESSORIES Optional accessories for the W olf [...]

  • Page 13

    13 INST ALLA TION INSTRUCTIONS INTERNAL BLO WERS INTERNAL BLO WER INST ALLA TION I MPORT ANT NOTE: F or mounting and installation of the internal blower , refer to the specific installation instructions provided with e ach blower . 1) Remove the hood filters. 2) Lift the blower into position inside the hood. 3) Use four hex nuts provided with the b[...]

  • Page 14

    14 W OLF COOKT OP VENTILA TION HOODS IMPORT ANT NOTE: Before turning the power on to the ventilation hood, make sure the b lower is in the OFF position. front electrical b ox T OP OF HOOD SHELL discharge collar red b lac k or white (neutral) HOOD FRONT small flat-blade screwdri ver Remote blower wiring A b lac k or white (neutral) red g reen/ y ell[...]

  • Page 15

    15 CONT ACT I NFORMA TION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com TROUBLE SHOO TING IMPORT ANT NOTE: If the cooktop ventilation hood does not operate properly , follow these t roubleshooting steps: V erify that power is being supplied to the ventilation hood. Check electrical connections to ensure that the installation has be[...]

  • Page 16

    807574 9 / 2005 WOLF APPLIANCE COMP ANY , LLC P . O . BOX 44848 MADISON, WI 53744 800-332-9513 WOLF APPLIANCE.COM[...]