Vermont Casting 2465 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting 2465, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting 2465 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting 2465. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Vermont Casting 2465 should contain:
- informations concerning technical data of Vermont Casting 2465
- name of the manufacturer and a year of construction of the Vermont Casting 2465 item
- rules of operation, control and maintenance of the Vermont Casting 2465 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting 2465 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting 2465, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting 2465.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting 2465 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DO NOT ST ORE OR USE GASOLINE OR OTHER FLAM- MABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from your neighbor ’s phone. Follow the gas [...]

  • Page 2

    2 Dutchwest Direct V ent / Natur al V ent Gas Heater 30001935 T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these ins[...]

  • Page 3

    3 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 General Information The Dutchwest Direct V ent/Natural V ent Room Heater , Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17- M91, Gas-Fired Appliances For Use at High Altitude[...]

  • Page 4

    4 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Dutchwest Direct V ent / Natural V ent Dimensions C L V alve Inlet 23" (584mm) 6  " (172mm) 24  " (622mm) C L V alve Inlet 1935 Dutchwest DV/NV dimensions 5/15/03 28  " (721mm) 12  " (318mm) 17" (419mm) 4  " ([...]

  • Page 5

    5 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Installation Requirements The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFP A 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude. Main- tain the manifold pressure at 3.5” w .c. fo[...]

  • Page 6

    6 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Parallel Installation: Minimum Clearance and Flue Centerline, Direct V ent and Natural V ent ST128b Stardance flue centerline 9/28/00 djt C L C L B D C A ST128c Stove Clearances A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines C: 15 ¹⁄₂ ” (395 mm) D: 9” (229 mm) Fig. 3 Parallel[...]

  • Page 7

    7 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h 2465 Nat Millivolt 28,000 20,000 2466 Prop Millivolt 28,000 19,000 Gas Specifications Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Natural LP (Propane) Inlet Minimum 5.5” w .c. 1 1.0” w .c. Inlet Maximum 1[...]

  • Page 8

    8 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ertical T ermination - Direct V ent ONL Y A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appli- ance flue collar . A 2 ¹⁄₄ ” restrictor plate (supplied) must be used where specified in all vertically terminated vent system[...]

  • Page 9

    9 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting T ermination Clearances Y our stove is approved to be vented either through the side wall, or vertical through the roof. • This unit does not require any opening for in- spection of vent pipe. • Only CFM Corporation and Simpson DuraV ent venting components specifically appro[...]

  • Page 10

    10 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Canadian Installations 1 US Installations 2 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I   Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev . 12/05/0[...]

  • Page 11

    1 1 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fig. 10 T ermination clearances. V enting Requirements - Natural V ent Only FP567 NVBR/NVBC VENTING RUNS 11/12/97 V enting Runs Horizontal Run (in feet) V ertical Run (in feet) (Measured from top of the unit before any elbow) A: V ertical installations up to 36 feet (12m) in height. [...]

  • Page 12

    12 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting Requirements and Options - Direct V ent ONL Y Approved V ent System Components The Dutchwest Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified [...]

  • Page 13

    13 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, V enting System Assembly . 1. The fan kit includes a Blower Assembly and a Rheo - stat Assembly , connected by a cable. (Fig. 12[...]

  • Page 14

    14 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V enting System Assembly - Direct V ent General Information The Dutchwest is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly . For U.S. installations: The venting system must con- form with local codes and/or the c[...]

  • Page 15

    15 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Install the V ent Adapter Pipe (Simpson Dura-V ent Components) 1. Install the Restrictor Plate. Consult the ‘V ent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar . (Fig. 16) 2.[...]

  • Page 16

    16 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 For DuraV ent pipe only: Install vent pipe by align- ing the locking system together , sliding the pipes together and twisting clockwise. • Install 90° elbow . T wist lock as before. • Slide the wall plate over horizontal run before at - taching the horizontal run to the elbow . Fas[...]

  • Page 17

    17 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 V ent T ermination Below Grade Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level. The seven inches is measured [...]

  • Page 18

    18 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints. (Fig. 31) 10. Add additional vent lengths to achieve the proper overall height. 1 1. A[...]

  • Page 19

    19 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Attach the first section of venting to the draft hood. De- pending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. Th[...]

  • Page 20

    20 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFP A 54. Since some municipalities have additional local codes, be sure to consult your local authority . In Canada; consult the local authority and CSA-B149.1 installation code. [...]

  • Page 21

    21 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 8. The air shutter is located on the bottom of the burner to the left. (Fig. 37) Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from th[...]

  • Page 22

    22 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge Maximum Run 18 20 feet 16 20 - 40 feet 14 up to 60 feet [...]

  • Page 23

    23 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Operation Y our First Fire Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly , Figure 45. Follow the lighting instructions on Page 25 exactly . During the first fire, it is not unusual to smell some odor associated with new[...]

  • Page 24

    24 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on [...]

  • Page 25

    25 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 T roubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. W ARNING: REMOVE THE GLASS P ANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM POSSIBLE CAUSES CORRECTIVE AC[...]

  • Page 26

    26 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions i[...]

  • Page 27

    27 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Pilot Orifice Conversion 1. Locate pilot. (Fig. 49) 2. Replace pilot orifice. Pilot T ype 1 • Remove pilot hood by lifting up. (Fig. 53) Do not remove snap ring to remove pilot hood. NOTE: It is not necessary to remove the pilot tube for conver- sion. • Remove pilot orifice with a[...]

  • Page 28

    28 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 21. Replace burner . Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possib[...]

  • Page 29

    29 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Maintenance Y our Dutchwest Gas Heater will provide years of ser - vice with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified ga[...]

  • Page 30

    30 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Gasket Replacement The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer . Shut off the gas supply and allow the stov[...]

  • Page 31

    31 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Wiring Diagrams OFF ON Thermostat (Optional)  Therm opile Black Black Millivolt Gas Valve St124b on/off/s witch wiring 1/11/00 djt TP/TH TP TH On/Off Switch Wiring ST124b Thermostat (Optional)  Therm opile Black Black Millivolt Gas Valve St124c Ther mostat?[...]

  • Page 32

    32 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 1a 1b 1c 2 10 12 1 1 PILOT ON OFF PILOT ADJ L O H I 23 27 28 32 CEMENT 34 35 1 3 4 6 7 5 8 13a,b 15a 17 19 14 18 20 21 15b 16a,b, c,d 25 26 24 33 29 31 9 22 30 1935 Dutchwest parts 5/16/03 djt 30 36 37a,b 38 CFM Corporation reserves the right to make changes in design, materials, speci?[...]

  • Page 33

    33 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Ref. Description Dutchwest Dutchwest Direct V ent / Natural V ent Gas Heater Models 2465, 2466 (continued) 10. Glass, DV25 1601691 1 1. Glass Frame Assembly - SDV30 30000127 12. Gasket, Glass - Med. Knit - RDV40 1203702 13a. V alve RN Honeywell VS8420E 2038 (Serial #’s up to 6413)* 100[...]

  • Page 34

    34 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provide[...]

  • Page 35

    35 Dutchwest Direct V ent / Natural V ent Gas Heater 30001935 LIMITED LIFETIME W ARRANTY PRODUCT COVERED BY THIS W ARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner . BASIC W ARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free f[...]

  • Page 36

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) 2465 63.0 2466 63.0 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation[...]