Telenetics MIU Dial or Leased Line modem with RS-485 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Telenetics MIU Dial or Leased Line modem with RS-485, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Telenetics MIU Dial or Leased Line modem with RS-485 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Telenetics MIU Dial or Leased Line modem with RS-485. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Telenetics MIU Dial or Leased Line modem with RS-485 should contain:
- informations concerning technical data of Telenetics MIU Dial or Leased Line modem with RS-485
- name of the manufacturer and a year of construction of the Telenetics MIU Dial or Leased Line modem with RS-485 item
- rules of operation, control and maintenance of the Telenetics MIU Dial or Leased Line modem with RS-485 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Telenetics MIU Dial or Leased Line modem with RS-485 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Telenetics MIU Dial or Leased Line modem with RS-485, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Telenetics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Telenetics MIU Dial or Leased Line modem with RS-485.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Telenetics MIU Dial or Leased Line modem with RS-485 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation, Operation and Diagnostics for your Communication Interface Unit MIU(Dial or Lease Line modem with) / 485 (RS485) ~ See MIUXXX for modem Technical Data Edition: June 17 , 2003 P / N: 0049 - 0002 - 010 rev A[...]

  • Page 2

    Installation, Operation & Diagnostics Edition: June 17 , 2003 Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) TABLE of CONTENTS 1.PRODUCT OVERVIEW ......................................................................... Page 1 2.PRODUCT DESCRIPTION .................................................................... Page 1 3[...]

  • Page 3

    Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 1 of 16 1. PRODUCT OVERVIEW The CIU (MIU XXX485) is an industrial modem with an RS - 232 to RS485 converter module for direct connection to industrial RS485 Interface units. Though similar to commercial modems, the MIUXXX 485 contains special features that m ake it particul[...]

  • Page 4

    Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 2 of 16 3. MIU'S LED, SWITCH & SERIAL CONNECTOR SPECIFICATIONS The CIU/485 communicates with industrial controllers through RS - 485 compatible serial signaling. The RS - 485 signal levels ar e used to interconnect with RS - 485 compatible embedded controllers. The RS [...]

  • Page 5

    Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 3 of 16 3.5 MIU/485 B switch (external) SB - 1 Closed (ON) RS485 Received RX & /RX DC terminated with SB - 2 Closed SB - 1 Open (OFF) RS485 Received RX & /RX AC terminated with SB - 2 Closed SB - 2 Closed (ON) RS485 Received RX & /RX terminated SB - 2 Open (OFF) RS4[...]

  • Page 6

    Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 4 of 16 4. POWER SUPPLY SPECIFICATIONS The MIUXXX/485 contains a low quiescent power regulator. TheMIUXXX/485 also has a "low power" standby mode which minimizes overall power requirements when the MIUXXX/485 is used intermittently. 4.1 Power Supply Selection (MIU) Th[...]

  • Page 7

    Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 5 of 16 5. RS485 SPECIFICATIONS MIUXXXX/485 are low - power Transceiver for RS485 and RS422 communication Features: Point to Point or Multidrop/Multipolling Full or Half Duplex Drivers are short - circuit current limited & protected against excessive power dissipation (shut[...]

  • Page 8

    Install Op and Diags for MIU Modems and RS485 (0049 - 0002 - 010A) Page 6 of 16 Operating Temperatures - 40 to 85 o C Storage Temperature - 55 to 100 o C Relative Humidity 0 to 95% is non - condensing. Altitude 20 ,000 ft (operating), 40,000 ft (shipping). Vibration Effect Withstand 10 to 500 Hz at 1 g on any axis per SAMA PMC - 31 - 1 without dama[...]

  • Page 9

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 SHEET TWO MIUXXX 485 Power Connection RJ11 Leased Line Port LED 1 Earth/Digital Ground (Jump pins if req’d) DB9 Data Port Power Connector Power In MIU (48 to 220VAC/DC (AC or DC) non-polarized Earth Gnd Power In MIU-LV (9 to 36VDC) Positive Voltage In Power Ground Earth Gnd L[...]

  • Page 10

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 SHEET TWO B Point-to-Point, 4-Wire: Set Switches B-3 & B-4 DOWN(OFF) Point-to-Point, 2-Wire: Set Switches B-3 & B-4 UP(ON) Line Terminate DC : Set Switches B-1 & B-2 UP(ON) Line Terminate AC : set Switches B-2 UP(ON) For LoopBack Test mode : Set Switches B-3 & B-4[...]

  • Page 11

    MIUXXX/4 85 Installation, Operation & Diagnostics Edition: June 17 , 2003 Page A - 1 APPENDIX A. CONNECTOR PIN DEFINITIONS CONNECTOR P2 : RS - 232 Configuration Connector (DB9) MIU DCD 1 data carrier detect from MIUXXX 485 RD 2 receive data from MIUXXX 485 TD 3 transmit data to MIUXXX 485 DTR 4 data terminal ready to MIUXXX 485 GND 5 gr[...]

  • Page 12

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 APPENDIX B. SETUP CONFIGURATION In order to configure the MIUXXX/485 to remote RTU, Meter or Sc ada terminals the following setup is required for 2w or 4w (RS485) networks See Fig ONE for MIUXXXX/485 layout and dip switch setting Final Factory Configuration (MIUXXXX/48[...]

  • Page 13

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 1:AT Command (MIU2400/485) (Dial) configuration is: AT E0Q1&C1&D0S0=1&W0 E0 Echo Command disables (no "AT" response to terminal) Q1 Result Codes disable (no result codes return to terminal ring) S0=1 Auto Answer active (first ring modem will go OF[...]

  • Page 14

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 &Z3=XX Password to exit security mode &C1 Carrier Detect is always True (MIU LED will be ON all the time wh en Carrier Detect is ON. &D0 DTR is ignored &K0 No flow control 4: AT Command (MIU9.6L/485) Lease Line ATE0Q1&C1&D0&K0&Q6 M0 [...]

  • Page 15

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 SB - 1 Closed(ON) DC Terminated SB - 2 Closed (ON) Line Termination SB - 3 & - 4 Open (OFF) 4 - wire SA - 1 Open (OFF) RTS follows CTS no delay SA - 2 Open (OFF) SA - 3 Closed (ON) RTS (always ON by MIU internal J7 (1/2) setting) enables TxEN) SA - 4 Open (OFF) TxD[...]

  • Page 16

    CIU Installation, Operation & Diagnostics Edition: June 17 , 2003 Page C - 1 To test RS485 module set switch SB - 3 & - 4 Closed (ON) to loopback data to the host modem. This test is for RS485 2 - wire and 4 - wire configurati ons. Connect MIUXXXX/485 TXY (+) and TXZ ( - ) to the embedded controller RS485 DIAGNOSTICS RS485 CONNECTION FAILUR[...]