SMC Networks Reed Switch Solid State Switches manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of SMC Networks Reed Switch Solid State Switches, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of SMC Networks Reed Switch Solid State Switches one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of SMC Networks Reed Switch Solid State Switches. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of SMC Networks Reed Switch Solid State Switches should contain:
- informations concerning technical data of SMC Networks Reed Switch Solid State Switches
- name of the manufacturer and a year of construction of the SMC Networks Reed Switch Solid State Switches item
- rules of operation, control and maintenance of the SMC Networks Reed Switch Solid State Switches item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of SMC Networks Reed Switch Solid State Switches alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of SMC Networks Reed Switch Solid State Switches, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the SMC Networks service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of SMC Networks Reed Switch Solid State Switches.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the SMC Networks Reed Switch Solid State Switches item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Applicable A uto Switch T ype Reed switch Solid state switch Auto s witch model Electrical entry Auto switch mounting Applicable rotary actuators Size Applicable air grippers Size P age 2-color indication 2-color indication With diagnosis output 2-color indication W ater resistant 2-color indication With timer Rail Rail Rail Rail Rail Rail Grommet [...]

  • Page 2

    1. Check the specifications. Read the specifications carefully and use this product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications of current current, voltage, temperature or impact. 2. Use caution when multiple cylinders are used and close to each other . When two or more auto switch cyli[...]

  • Page 3

    1. Do not drop or bump. Do not drop, bump, or apply excessive impacts (300 m/s 2 or more for reed switches and 1000 m/s 2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. N[...]

  • Page 4

    1. Never use in the presence of explosive gases. The construction of our auto switches does not make them explosion-proof. Never use them in the presence of an explosive gas, as this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become dem[...]

  • Page 5

    Before Operation Auto Switches Common Specifications Auto Switches Common Specifications Lead Wire Length Lead wire length indication Contact Protection Box: CD-P11, CD-P12 D-A73 Nil L 0.5 m 3 m L Leakage current Operating time Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure Reed switch None 1.2 ms 300 m/s 2 [...]

  • Page 6

    Before Operation Auto Switches Connection and Example Basic Wiring Example of Connection with PLC (Programmable Logic Controller) Example of AND (Series) and OR (Parallel) Connection Solid state 3-wire, NPN Solid state 2-wire Solid state 3-wire, PNP Main curcuit of switch Brown Black Blue Brown Black Blue Brown Blue Brown Blue Reed switch 2-wire In[...]

  • Page 7

    Reed Switch Band Mounting Style D-A72/D-A73/D-A80 Auto Switch Specifications Dimensions Grommet Electrical entry: Perpendicular Weight Auto switch model 0.5 3 5 10 47 — 10 47 77 10 47 — D-A72 D-A73 D-A80 (g) Lead wire length (m) PLC: Abbreviation of Programmable Logic Controller D-A7 (With indicator light) Auto switch model Applicable load Load[...]

  • Page 8

    Indicator light D-A80H without indicator light Most sensitive position Auto Switch Internal Circuit D-A72H D-A73H D-A76H D-A80H Auto Switch Specifications Dimensions Auto switch model 0.5 3 5 10 47 — 10 47 — 11 52 — 10 47 77 D-A72H D-A73H D-A76H D-A80H D-A7  H , D-A80H Grommet Electrical entry: In-line Lead wire length (m) PLC: Abbreviatio[...]

  • Page 9

    Indicator light D-A80C without indicator light Most sensitive position Lead wire with connector Reed Switch Rail Mounting Style D-A73C/D-A80C Auto Switch Internal Circuit D-A73C D-A80C Auto Switch Specifications Dimensions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deterior[...]

  • Page 10

    ( ): dimensions for D-A93. D-A90V , D-A93V , D-A96V Auto Switch Specifications Grommet Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller D-A90, D-A90V (Without indicator light) Auto switch model Applicable load Load voltage Maximum load current Contact protection circuit Internal resistance D-A93, D-A93V, D-A96, D-A96V (W[...]

  • Page 11

    Most sensitive position Auto Switch Internal Circuit D-A79W Auto Switch Specifications Weight Dimensions Grommet Indicator light / Display method Auto switch model 0.5 3 5 11 53 — D-A79W Lead wire length (m) Note 1) Operating load is an induction load. Note 2) Wiring to the load is 5 m or longer. Use the contact protection box in any of the above[...]

  • Page 12

    Auto Switch Internal Circuit D-F79 D-J79 D-F7P Auto Switch Specifications Weight Dimensions Auto switch model 0.5 3 5 D-F79 D-F7P D-J79 Grommet Lead wire length (m) D-F7  , D-J79 (With indicator light) PLC: Abbreviation of Programmable Logic Controller Auto switch model Wiring type Output type Applicable load Power supply voltage Current consump[...]

  • Page 13

    Indicator light Most sensitive position ø3.5 mounting hole Auto Switch Internal Circuit D-F7NV D-F7BV D-F7PV Auto switch model 0.5 3 5 13 57 92 13 57 92 11 50 81 D-F7NV D-F7PV D-F7BV Grommet Electrical entry: Perpendicular Lead wire length (m) D-F7  V (With indicator light) Auto switch model Wiring type Output type Applicable load Power supply [...]

  • Page 14

    Auto Switch Internal Circuit D-J79C Auto switch model 0.5 3 5 13 52 83 D-J79C Connector Lead wire length (m) D-J79C Auto switch model Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light D-J79C 2-wire — 24 VDC Relay, PLC — — 24 VDC (10 [...]

  • Page 15

    Grommet D-F8N D-F8B D-F8P Auto switch model Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current I nternal voltage drop Leakage current Indicator light D-F8N Perpendicular NPN 28 VDC or less 40 mA or less D-F8B Perpendicular 2-wire — 24 VDC relay, PLC — — 24 VDC [...]

  • Page 16

    Auto Switch Internal Circuit D-M9N, D-M9NV D-M9B, D-M9BV D-M9P, D-M9PV Auto switch model 0.5 3 5 D-M9N(V) 8 41 68 D-M9P(V) 8 41 68 D-M9B(V) 7 38 63 Lead wire length (m) • Lower load current • Lead free solder • Using UL certified (style 2844) lead wire Grommet D-M9  , D-M9  V (With indicator light) Auto switch model Electrical entry dir[...]

  • Page 17

    D-Y5  , D-Y6  , D-Y7P , D-Y7PV (With indicator light) Auto switch model Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light D-Y59A In-line 3-wire NPN IC circuit, Relay, PLC 5, 12, 24 VDC (4.5 to 28 V) 28 VDC [...]

  • Page 18

    Auto switch model 0.5 3 5 13 57 92 13 57 92 11 50 81 D-F79W D-F7PW D-J79W Lead wire length (m) Auto Switch Internal Circuit D-F79W D-J79W Indicator light / Display method D-F7PW Grommet D-F7  W, D-J79W Auto switch model Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage dro[...]

  • Page 19

    Auto Switch Internal Circuit D-Y7NW, D-Y7NWV D-Y7BW, D-Y7BWV D-Y7PW, D-Y7PWV Grommet Indicator light / Display method The optimum operating position can be determined by the color of the light. (Red → Green ← Red) D-Y7  W, D-Y7  WV (With indicator light) Auto switch model Electrical entry direction Wiring type Output type Applicable load [...]

  • Page 20

    Auto Switch Internal Circuit D-F9NW, D-F9NWV D-F9BW, D-F9BWV D-F9PW, D-F9PWV Grommet D-F9  W, D-F9  WV (With indicator light) Auto switch model Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light D-F9NW In-li[...]

  • Page 21

    Auto Switch Internal Circuit Diagnostic Output Operation Dimensions Auto switch model 0.5 3 5 13 56 90 D-F79F Grommet Lead wire length (m) ø3.4 Since the output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). The diagnostic signal is out[...]

  • Page 22

    Auto Switch Internal Circuit Dimensions Grommet Water (coolant) resistant type Please consult with SMC if using coolant liquid other than water based solution. Indicator light / Display method D-F7BA(V)L (With indicator light) Auto switch model Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumpti[...]

  • Page 23

    Auto Switch Internal Circuit Dimensions Grommet Water (coolant) resistant type Please consult with SMC if using coolant liquid other than water based solution. Indicator light / Display method ø2.7 Auto switch model Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leak[...]

  • Page 24

    Auto Switch Internal Circuit Dimensions Grommet Auto switch model 0.5 3 5 D-Y7BA — 54 88 Lead wire length (m) Water (coolant) resistant type Please consult with SMC if using coolant liquid other than water based solution. Indicator light / Display method D-Y7BAL (With indicator light) Auto switch model Wiring type Applicable load Load voltage Loa[...]

  • Page 25

    Made to Order Specifications: Solid State Switch With Pre-wired Connector • Eliminates the harnessing work by cable with connector specifications • Adopts global standardized connector (IEC947-5-2) • IP67 construction How to Order Cable length Solid state switch Standard part no. D— M9N S A PC 0.5 m 1.0 m 3.0 m S M L Connector model M8—3 [...]

  • Page 26

    Connector Pin Arrangement Dimensions Sensor type DC 2-wire type DC 2-wire, Non-polar type DC 3-wire type DC 4-wire type Brown — Brown Brown 1 pin — — — Orange 2 pin — Brown Blue Blue 3 pin Blue Blue Black Black 4 pin Color distinction of lead wire Meaning of contact number OUT (+) — DC (+) DC (+) 1 pin — — — Diagnostic output 2 pi[...]

  • Page 27

    Made to Order Specifications: Solid State Switch -50: No Indicator (Dark room) Specifications -61: Oil Resistant, Flexible Cable Specifications -50 Without Indicator Light (for dark room specifications) Possible to use under the environment which hates a light. 50 D Solid state switch model 61 D Applicable part no.: General purpose type, solid stat[...]