Sierra 730 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Sierra 730, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sierra 730 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Sierra 730. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Sierra 730 should contain:
- informations concerning technical data of Sierra 730
- name of the manufacturer and a year of construction of the Sierra 730 item
- rules of operation, control and maintenance of the Sierra 730 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sierra 730 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sierra 730, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sierra service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sierra 730.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Sierra 730 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Sierra Series 730 Accu-Mass ™ Mass Flow Meters Instruction Manual Part Number IM-73-AM Revision E 0 5 /0 4 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com Sierra Instruments b.v. Bolstoen 30A 1046 AV Amsterdam The Netherlands +31(0)20-6145810 Fax +31(0)20-6145815[...]

  • Page 2

    Customer Notice Sierra Instruments, Inc. is not liable for any damage or personal injury, whatsoever, resulting from the use of Sierra Instruments standard mass flow meters for oxygen gas. You are responsible for determining if this mass flow meter is appropriate for your oxygen application. You are responsible for cleaning the mass flow meter to t[...]

  • Page 3

    Series 730 Instruction Manual IM-73- E 1 Table of Contents Series 730 Mass Flow Meters...........................................................3 Safety Information..........................................................................4 Receipt of Components...................................................................4 Technical Assistanc[...]

  • Page 4

    Series 730 Instruction Manual 2 IM-73- E Warnings and Cautions Warning! All wiring procedures must be performed with the power Off. Caution! All flow meter connections and fittings must have the same or higher pres- sure rating as the main pipeline. Caution! Do not connect power to the 4-20 mA terminals. Caution! Before attempting any flow meter re[...]

  • Page 5

    Series 730 Instruction Manual IM-73- E 3 Series 730 Mass Flow Meters Sierra’s Series 730 Accu-Mass ™ Flow Meters provide outstanding measurement accuracy and fast 200 millisecond response time. The meters monitor the mass flow rate of air and process gases in ranges from 0 to 250 scfm. They are available in pipe sizes from 1/4-inch to 3 inches.[...]

  • Page 6

    Series 730 Instruction Manual 4 IM-73- E Safety Information We use caution and warning statements in this book to draw your at- tention to important information. Warning! Caution! This statement appears with information that is important to protect people and equipment from damage. Pay very close attention to all warn- ings that apply to your appli[...]

  • Page 7

    Series 730 Instruction Manual IM-73- E 5 Installation Overview When selecting an installation site, make sure that: 1. Line pressure and temperature will not exceed the flow meter rating. Temperature should not vary more than 120°F (50°C) from the calibration temperature. Line pressure should not vary more than 50 psi (3.4 bar) around the calibra[...]

  • Page 8

    Series 730 Instruction Manual 6 IM-73- E Flow meter 10 D 5 D One 90° elbow before meter Flow meter 15 D 5 D Two 90° elbows before meter in one plane Flow meter 25 D 10 D Two 90° elbows before meter out of plane (if three 90° bends present, double recommended length) Flow meter 10 D 5 D Reduction before meter Flow meter 20 D 5 D Expansion before[...]

  • Page 9

    Series 730 Instruction Manual IM-73-D 7 Wiring Connections - NEMA 2 CE Enclosures NEMA 2 enclosures are supplied with a 6 -pin connector for direct connection to the supplied mating connector. The pin designations are given in Figure 3 below. Connect 15 VDC input power (300 mA load, maximum) to pin 1 and power ground to pin 5 . See “Output Sig- n[...]

  • Page 10

    Series 730 Instruction Manual 8 IM-73- E Output Signal Wiring All flow meters are equipped with either a calibrated 0–5 VDC, 0–10 VDC or 4–20 mA output signal. These linear output signals represent 0 to 100% of the flow meter user full scale. DC Output Wiring The 0-5 VDC or 0-10 VDC output signal can drive a minimum load of 1000 Ohms. For 0-5[...]

  • Page 11

    Series 730 Instruction Manual IM-73- E 9 Problem Possible Cause Solution Flow measurement is erratic or fluctuating Very erratic or non-uniform flow Follow installation requirements shown in Figure 2 Flow meter installed with less than re- quired minimum pipe diameters up- stream and downstream of the sensor Follow installation requirements shown i[...]

  • Page 12

    Series 730 Instruction Manual 10 IM-73- E Returning Equipment to Factory Before returning any mass flow meter to the factory, you must com- plete a Sierra Calibration/Repair Data Sheet. You may download the data sheet to your computer by visiting the Sierra website at www.sierrainstruments.com. Or, contact Customer Service at: service@sierrainstrum[...]

  • Page 13

    Series 730 Instruction Manual IM-73- E 11 Product Specifications Operating Specifications Gases Most non-combustible, non-corrosive gases Mass Flow Rates Mass Flow Rate for Air (1) NPT Size Minimum Range Maximum Range 1/4-inch 0–0.035 scfm 0–4.5 scfm 1/2-inch 0–0.5 scfm 0–12 scfm 3/4-inch 0–1 scfm 0–25 scfm 1 1/4-inch 0–2 scfm 0–50 [...]

  • Page 14

    No#. Color Signal 1 Black Sig. Ground 2 White Signal 3 Red DC input P ower 4 N/C 5 N/C 6 Green P ower Ground 7 (Brown or Orange) (Bridge) 730/600 WIRING C ONNECTIONS Blue Hi Rose Connector F emale Mating Connector Solder Side No#. Color Signal 1 Black Sig. Ground 2 White Signal 3 Red DC input P ower 4 N/C 5 N/C 6 Green Po wer Ground 7 (Brown or Ora[...]