Royal Sovereign ARP-1000ES manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Royal Sovereign ARP-1000ES, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Royal Sovereign ARP-1000ES one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Royal Sovereign ARP-1000ES. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Royal Sovereign ARP-1000ES should contain:
- informations concerning technical data of Royal Sovereign ARP-1000ES
- name of the manufacturer and a year of construction of the Royal Sovereign ARP-1000ES item
- rules of operation, control and maintenance of the Royal Sovereign ARP-1000ES item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Royal Sovereign ARP-1000ES alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Royal Sovereign ARP-1000ES, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Royal Sovereign service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Royal Sovereign ARP-1000ES.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Royal Sovereign ARP-1000ES item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Roy al Centurian Inc. POR T ABLE AIR CONDITIONER A CONDICIONADOR DE AIRE PORT Á TIL Read and retain these instructions for future reference For any Customer Support needs, please choose the Support tab on www.royalsovereign.com ARP- 1000ES O WNER’S MANU AL ARP-1000ES POR T ABLE AIR CONDITIONER[...]

  • Page 2

    PORT ABLE AIR CONDITIONER Model ARP-1000ES INTR ODUCTION Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, apartment, or office. This appliance can be moved from room to room and set-up in just minutes. It is multi-functional room air conditioner that offe[...]

  • Page 3

    W ARNING - Make sure rubber plug is installed in drain port on bottom of the machine. Improper handling can cause serious damage to the appliance. Read this manual carefully before operating the unit. 3 Do not cover the air outlet while in use. Do not wet the housing or control panel. Do not allow children to play with the controls or drop any obje[...]

  • Page 4

    4 DESCRIPTION OF COMPONENTS 1. Control panel 2. Air outlet (Up-Down and Left-Right) 3. Front panel 4. Handle hole 5. Casters 6. Screen filter 7. Air intake (Evaporator) 8. Air intake (Condenser) 9. Air outlet (Heat exchange) 10. Water drain with rubber plug[...]

  • Page 5

    5 1. Insert ends of exhaust hose into exhaust nozzle connector and exhaust hose connector by twisting clockwise until it stops. 2. Attach the exhaust hose connector onto the rear outlet of the unit and turn to the right. 3. Attach the exhaust nozzle to the window spacer with the 4 screws provided. 4. Connect the exhaust nozzle connector to the exha[...]

  • Page 6

    6 POWER CONTROL The power control turns the unit on and off. WARNING CONTROL Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning Light will shine and the unit will not operate until the unit has been drained. FAN MODE When fan mode is selected the indicator light will shine yellow. Air is circulated throughout[...]

  • Page 7

    DEHUMIDIFY MODE When dehumidify mode is selected, the indicator light will shine orange. Air is dehumidified as it passes through the unit, without being in full cooling mode. The fan will operate in low or medium speed. Fan speed is not adjustable in dehumidify mode. NOTE : The air exchange hose must vent outside the room thru a window as usual. C[...]

  • Page 8

    8 Power ON / OFF Button Mode Button (Select A/C, Fan or Dehumidify) Timer and thermostat Setting Buttons A/C Fan Speed Button (High, Medium or Low) Timer ON/OFF Button LCD Screen OPERA TION Fahrenheit / Celsius Selector Air Conditioner Remote Control The functions work the same as your air conditioner's touch controls. TIMER PROGRAMMING 1. Pre[...]

  • Page 9

    TR OUBLESHOO TING Does not run Operates for short time only Runs but not cooling Does not run and water full indicator lights If the surge protector is tripped. Press the reset button the the LCI plug. Please wait for 3 minutes and start again, protector device may be preventing unit from working. If batteries in the remote control need replacement[...]

  • Page 10

    10 Appliance maintenance Air filter maintenance It is necessary to clean the air filter after using it for about 100 hours. Clean it as follows. 1. Cut off the power supply Turn off the appliance first before disconnecting from power supply 1. Stop the appliance and remote the air filter 2. Clean and reinstall the air filter Wash it with a solution[...]

  • Page 11

    14 ARP-1000ES Description of product Air Conditioner Model ARP-1000ES Voltage / Frequency 115A / 60Hz Input power 950W Operating cycle 9A Cooling capacity 10000 B.T.U. 2.6 KW EER 10.5 Dehumidifying capacity 3.3pints / 1.6L / Hour Coolant R-22 Timer 12 hour Dimensions 18.5 x 34.2 x 14 (W) x (H) x (D) 47.0cm x 87.0cmm x 35.5cm Weight (N.W.) 79.3lbs /[...]

  • Page 12

    FULL ONE YEAR WARRANTY Royal Sovereign warrants each Portable Air Conditioner to be free from defects in material and workmanship. Our obligation under this warranty is limited to the repair or replacement, free of charge, when delivered to an authorized Royal Sovereign service center, of any defective part(s) thereof, other than parts damaged in t[...]

  • Page 13

    ARP-1000ES Roy al Centurian Inc. A CONDICIONADOR DE AIRE PORT Á TIL Lea y conserve estas instrucciones para referencia futura Para preguntas, por favor. Visite nuestra página de internet www.royalsovereign.com servicio al cliente. ARP- 1000ES MANU AL DEL PR OPIET ARIO ARP-1000ES A CONDICIONADOR DE AIRE POR T Á TIL[...]

  • Page 14

    ACONDICIONADOR DE AIRE PORTÁTIL Modelo ARP-1000ES INTR ODUCCIÓN Gracias por elegir este acondicionador de aire portátil para proporcionarle a usted y a su familia todos los requisitos de “comodidad hogareña” para su casa, departamento u oficina. Este dispositivo se puede mover de una habitación a otra y configurar en pocos minutos. Es el a[...]

  • Page 15

    AD VER TENCIA - El manejo inadecuado puede provocar daños graves al dispositivo. Lea detenidamente este manual antes de poner en funcionamiento la unidad. Compruebe que el tapón de goma este instalado en el orificio de desagüe en la parte inferior de la máquina. 15 No cubra la salida de aire mientras esté en uso. No moje la cubierta ni el pane[...]

  • Page 16

    DESCRIPCIÓN DE LOS COMPONENTES 1. Panel de control 2. Salida de aire (de arriba a abajo y de izquierda a derecha) 3. Panel frontal 4. Orificio de la manilla 5. Ruedas giratorias 6. Filtro de malla 7. Entrada de aire (evaporador) 8. Entrada de aire (condensador) 9. Salida de aire (intercambio térmico) 10. Desagüe 16[...]

  • Page 17

    1. Inserte los extremos de la manguera de escape en los conectores de la tobera y de la manguera de escape girándolos en el sentido de las agujas del reloj hasta que se detengan. 2. Conecte la manguera de escape en la salida posterior de la unidad y gírelo hacia la derecha. 3. Conecte la tobera de escape al separador de la ventana con los 4 torni[...]

  • Page 18

    CONTROL DE ENCENDIDO El control de encendido enciende y apaga la unidad. CONTROL DE ADVERTENCIA Es posible que se acumule agua condensada en la unidad. Si se llena el tanque interno, se encenderá la luz de advertencia y la unidad no funcionará hasta que ésta se haya desaguado. MODO DE VENTILACIÓN Cuando se selecciona este modo, la luz indicador[...]

  • Page 19

    Después de apagar el acondicionador de aire, debe esperar 3 minutos antes de encenderlo nuevamente. ARP- 1000ES MODO DE DESHUMIDIFICACIÓN Cuando se selecciona este modo, la luz indicadora se enciende de color naranja. El aire se deshumidifica a medida que pasa a través de la unidad, sin estar por completo en el modo de enfriamiento. El ventilado[...]

  • Page 20

    PROGRAMACIÓN DEL TEMPORIZADOR 1. Presione el botón del control remoto o el botón de ajuste del temporizador del panel de control para activar la función de temporizador. 2. Presione el botón o del control remoto, o los botones + o - del panel de control para ajustar el período de apagado que desee. 3. La unidad se apagará cuando transcurra l[...]

  • Page 21

    SOLUCIÓN DE PR OBLEMAS No funciona Funciona sólo durante un período breve Funciona, pero no enfría No funciona y se enciende el indicador de máxima capacidad de agua Si el desenganche o fusible protector está quemado. Espere 3 minutos y enciéndalo nuevamente, es posible que el dispositivo protector impida que funcione la unidad. Si se deben [...]

  • Page 22

    SOLUCIÓN DE PR OBLEMAS Mantenimiento del dispositivo Mantenimiento del filtro de aire Se debe limpiar el filtro de aire después de usarlo durante 100 horas aproximadamente. Límpielo como se indica a continuación. 1. Corte el suministro eléctrico Primero apague el dispositivo antes de desconectarlo del suministro eléctrico 1. Detenga el dispos[...]

  • Page 23

    14 ARP-1000ES Descripción del producto Acondicionador de aire Modelo ARP-1000ES Voltaje/Frecuencia 115A / 60Hz Potencia de entrada 950W Ciclo de trabajo 9A Capacidad de enfriamiento 10000 unidades térmicas 2.6 KW Capacidad de deshumidificación 3.3 pintas/1.6 L/hora Enfriador R-22 Temporizador 12 horas Dimensiones 18.5 x 34.2 x 14" (A) x (A)[...]

  • Page 24

    GARANTÍA TOTAL DE UN AÑO Royal Sovereign garantiza que todos los acondicionadores de aire portátiles están libres de defectos de material y de mano de obra. Nuestra obligación de acuerdo con esta garantía se limita a la reparación o el reemplazo sin costo de cualquier pieza defectuosa que no haya sido dañada en tránsito, cuando se entregue[...]