Porter-Cable CPF23400S manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Porter-Cable CPF23400S, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Porter-Cable CPF23400S one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Porter-Cable CPF23400S. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Porter-Cable CPF23400S should contain:
- informations concerning technical data of Porter-Cable CPF23400S
- name of the manufacturer and a year of construction of the Porter-Cable CPF23400S item
- rules of operation, control and maintenance of the Porter-Cable CPF23400S item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Porter-Cable CPF23400S alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Porter-Cable CPF23400S, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Porter-Cable service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Porter-Cable CPF23400S.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Porter-Cable CPF23400S item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Part No. D20692-005 Side Stack Compressor Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for futur e reference. Model No. T ype Serial No. ESP AÑOL: PÁGINA 13 FRANÇAISE: P AGE 27 I[...]

  • Page 2

    2-ENG CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to pr otecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS . T o help you recognize this information, we use the sy[...]

  • Page 3

    3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MA Y IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE. UNA T[...]

  • Page 4

    4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y . AL WA YS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS WHEN [...]

  • Page 5

    5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P ARTS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING. A TTEMP[...]

  • Page 6

    6-ENG CFM: Cubic feet per minute. SCFM: Standar d cubic feet per minute; a unit of measure of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressur e. ASME: American Society of Mechanical Engineers; made, tested, inspected, and register ed to meet the standards of ASME. Cut-In Pressur e: While the motor is off, air tank p[...]

  • Page 7

    7-ENG DESCRIPTION OF OPERA TION Compressor Pump (A) Fig. 1: To compress air , the piston moves up and down in the cylinder . On the downstroke, air is drawn in thr ough the intake valves. The exhaust valves remain closed. On the upstr oke of the piston, air is compressed. The intake valves close and compressed air is forced out thr ough the exhaust[...]

  • Page 8

    8-ENG Outlet Pressur e Gauge (F) Fig. 1: The outlet pressure gauge indicates the air pressur e available at the outlet side of the regulator . This pressure is contr olled by the regulator and is always less than or equal to the tank pr essure. See “Operating Procedures”. T ank Pressure Gauge (G) Fig. 3: The tank pr essure gauge indicates the r[...]

  • Page 9

    9-ENG GROUNDING INSTRUCTIONS The air compressor is equipped with a cord having a gr ounded wire with an appropriate gr ounding plug. The plug must be used with an outlet that has been installed and grounded in accor dance with all local codes and ordinances. The outlet must have the same configuration as the plug. See illustration. DO NOT USE AN AD[...]

  • Page 10

    10-ENG OPERA TING PROCEDURES Preparation for Use: 1. Before attaching air hose or accessories, make sur e the OFF/AUTO lever is set to “OFF” and the air regulator is closed. 2. Inspect air intake filter (H) Fig. 1. Clean or replace as necessary . 3. Attach hose and accessories. TOO MUCH AIR PRESSURE CAUSES A HAZARDOUS RISK OF BURSTING. CHECK TH[...]

  • Page 11

    11-ENG SERVICE AND REP AIRS All quality tools will eventually requir e servicing or replacement of parts due to wear from normal use. These operations should ONL Y be performed by either an AUTHORIZED PORTER-CABLE SER VICE ST A TION or a PORTER- CABLE SER VICE CENTER. All repairs made by these agencies are fully guaranteed against defective materia[...]

  • Page 12

    12-ENG LIMITED WARRANTY PORTER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is fr ee from defects in material and workmanship and agrees to repair or r eplace under this warranty any defective product or part as follows from the original date of purchase. 5 YEARS – Limited warranty on 2-stage[...]