Pelco EH66X manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco EH66X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco EH66X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco EH66X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco EH66X should contain:
- informations concerning technical data of Pelco EH66X
- name of the manufacturer and a year of construction of the Pelco EH66X item
- rules of operation, control and maintenance of the Pelco EH66X item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco EH66X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco EH66X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco EH66X.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco EH66X item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Pelco Manual C411M-D (1/96) 17 Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com (559) 292-1981 or (800) 289-9100 • FAX (559) 292-3827 or (800) 289-9150 EH66/EH66X Envir onmental Enclosur es Installation/Operation Manual C411M-D (1/96) ®[...]

  • Page 2

    TABLE OF CONTENTS S ection P age 1.0 W ARNINGS ........................................................................................................................................ 1 2.0 SCOPE ............................................................................................................................................... 2 3.0 DESC[...]

  • Page 3

    LIST OF ILLUSTRA TIONS F igur e P age 1 EH66/EH66X Dimension Dra wing ................................................................................................. 2 2 Wiring Diagram f or Windo w Defroster , Wiper/W asher and Blow er/Heater Assemblies ................. 4 3 EH66 Enclosure with Wall Mount .........................................[...]

  • Page 4

    This page intentionally left blank. iv Pelco Manual C411M-D (1/96)[...]

  • Page 5

    Pelco Manual C411M-D (1/96) 1 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. CAUTION : TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS[...]

  • Page 6

    2 Pelco Manual C411M-D (1/96) 2.0 SCOPE The information contained within this manual covers the EH66/EH66X Series environmental enclosure. 3.0 DESCRIPTION The EH66 Series is an all-weather environmental enclo- sure for 2/3" and 1" cameras with a maximum camera/ lens size of 7" W x 7" H x 22" L (17.7 cm x 17.7 cm x 55.8 cm).[...]

  • Page 7

    Pelco Manual C411M-D (1/96) 3 NOTE : Cameras with a low optical centerline or using a large diameter lens require an ele va- tion block (1 inch or 2 inch) for proper posi- tioning. See Section 8.0, Optional Accessories, for the correct model number . 3. Replace the camera/sled assembly onto the rail and slide along the rail to adjust the camera to [...]

  • Page 8

    4 Pelco Manual C411M-D (1/96) Figure 2 . Wiring Diagram for Window Defroster, Wiper/Washer and Blower/Heater Assemblies to control[...]

  • Page 9

    Pelco Manual C411M-D (1/96) 5 4.3 FIXED ENCLOSURE MOUNTING The are two types of mounts that can be used with the EH66 enclosure: wall, or pedestal/ceiling (see Figures 3 and 4). Instructions for mounting the enclosure are as follows: 1. Select the appropriate mount (WM2000 for wall mounting or PM2000/PM2010 for pedestal mount- ing) for the applicat[...]

  • Page 10

    6 Pelco Manual C411M-D (1/96) 4.4 P AN/TIL T ENCLOSURE MOUNTING The EH66 enclosure can also be mounted to a pan/tilt assembly in addition to the wall or pedestal/ceiling mount. To include the pan/tilt assembly in your configuration, perform the following steps: 1. Select the appropriate mount (WM2000 for wall mounting, PM2000/PM2010 for pedestal mo[...]

  • Page 11

    Pelco Manual C411M-D (1/96) 7 4.5 WINDOW WIPER INST ALLA TION To install the window wiper kit, perform the following steps and refer to Figures 7 and 8: 1. Turn the EH66 enclosure over so the bottom is facing up. 2. If necessary, lay out the locations of the four (4) .171-inch diameter mounting holes using the di- mensions given in Figure 8. 4. Att[...]

  • Page 12

    8 Pelco Manual C411M-D (1/96) 4.6 B66KIT/E624HB/H66KIT INST ALLA TION All heater and blower kits are supplied partially as- sembled. Install in the enclosure according to the fol- lowing instructions: 1. Remove the round cap on the rear of the enclosure and the two (2) 8-32 screws and nuts located on each side of the opening above the horizontal li[...]

  • Page 13

    Pelco Manual C411M-D (1/96) 9 Figure 9 . EH66 Enclosure Exploded Assembly Diagram 6.0 EXPLODED ASSEMBL Y DIAGRAMS See Figures 9 and 10 for exploded assembly diagrams of the EH66 enclosure and WW66, WW66-5/220 wiper assembly.[...]

  • Page 14

    10 Pelco Manual C411M-D (1/96) Figure 10 . WW66, WW66-5/220 Wiper Exploded Assembly Diagram NOTE: FIGURE DOES NOT REPRESENT CURRENT PUMP IN USE.[...]

  • Page 15

    Pelco Manual C411M-D (1/96) 11 7.0 MECHANICAL P ARTS LISTS 7.1 MECHANICAL AND ELECTRICAL PARTS LIST FOR EH66 ENCLOSURE Item No. Qty Description Part Number 1 4 Gasket, Window Frame EH110042 2 1 Gasket, Cable Entry EH110072 3 1 Plate, Cable Entry EH14231COMP 4 2 Gasket, Rim EH450010000 5 2 Gland, UL, PG-13.5 black EH470010007B 6 2 Nut, UL Gland, 13.[...]

  • Page 16

    12 Pelco Manual C411M-D (1/96) 7.2 MECHANICAL P ARTS LIST FOR WW66 AND WW66-5/220 WINDOW WIPER ASSEMBL Y Item No. Qty Description Part Number 1 3 Bearing 776003 2 1 Diode DIOPT40F 3 — Not used — 4 1 Switch SWIV3L 5 1 Spacer, 1/4" Hex x .6254-40 tap SPA8404 6 1 Transformer TRF21162.01.0CM 7 1 Pump WW6610031 8 12 Tubing, Vinyl, 1/8 ID x 1/4 [...]

  • Page 17

    Pelco Manual C411M-D (1/96) 13 8.0 OPTIONAL ACCESSORIES FACTORY INSTALLED EHRC Relay module for low voltage control of wiper/washer and camera on/off. Requires MEH24DT control module. TI66 Thermal insulation provides increased thermal protection for enclosure and contents at extreme temperatures (for model EH66 series only). T166X Thermal insulatio[...]

  • Page 18

    14 Pelco Manual C411M-D (1/96) 9.1 RECOMMENDED CABLE SIZE CAUTION : When a single po wer source is used for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge. The following cable sizes are the minimum recom- mended for use with the combination of defroster/ blower/heater/c[...]

  • Page 19

    Pelco Manual C411M-D (1/96) 15 10.0 WARRANTY AND RETURN INFORMATION PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR80[...]

  • Page 20

    16 Pelco Manual C411M-D (1/96) Pelco 3500 Pelco Way, Clovis, CA 93612-5699 • (559) 292-1981 • (800) 289-9100 FAX (559) 292-3827 • (800) 289-9150 • www.pelco.com International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.) C411M-D ®[...]