Pelco C417M-L manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Pelco C417M-L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Pelco C417M-L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Pelco C417M-L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Pelco C417M-L should contain:
- informations concerning technical data of Pelco C417M-L
- name of the manufacturer and a year of construction of the Pelco C417M-L item
- rules of operation, control and maintenance of the Pelco C417M-L item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Pelco C417M-L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Pelco C417M-L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Pelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Pelco C417M-L.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Pelco C417M-L item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EHX*E Series Explosionproof Camera Enclosure C417M-L (7/03) ® INST ALLA TION/OPERA TION[...]

  • Page 2

    2 C417M-L (7/03)[...]

  • Page 3

    C417M-L (7/03) 3 CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. IMPORT ANT SAFEGUARDS AND W ARNINGS Observe the following W ARNINGS before installing and using this product. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Only use replacement parts Pelco recommends. 3. The installat[...]

  • Page 4

    4 C417M-L (7/03) DESCRIPTION The EHX*E Series of nonpressurized, explosionproof camera enclosures is designed to meet the rigorous requirements of explosionproof and dust-ignitionproof electrical equipment for installation and use in hazardous locations. The EHX*E Series is constructed of aluminum and available in 4-, 6-, and 8-inch diameters to ac[...]

  • Page 5

    C417M-L (7/03) 5 INST ALLA TION The following parts are supplied: 1 Enclosure with attached mounting cradle 1 3/16-inch Allen wrench 15 mm Allen wrench 2 1/4-20 x 1/2-inch screws 2 Appleton explosionproof sealable fittings 1 Desiccant bag 1 Sealing instructions for fittings (C903M-A) 1 Service kit 1 Rear O-ring 4 Rear plate mounting screws 1T ube o[...]

  • Page 6

    6 C417M-L (7/03) 13. If required, attach a ground wire to the terminal lug on the rear plate. IMPORT ANT NOTE: The internal grounding terminal must be used for the equipment grounding connection and the external terminal is for a supplementary bonding connection where local codes or authorities permit or require such connection. 14. Connect the vid[...]

  • Page 7

    C417M-L (7/03) 7 OPERA TION If your enclosure has a heater , the heater turns on at 40 ° F (4 ° C) and turns off at 60 ° F (16 ° C). If your enclosure has a blower , the fan operates continuously . MAINTENANCE REGULAR MAINTENANCE WARNING: Do not remove the front cover . If you do, Pelco cannot be held responsible for the loss of explosionproof [...]

  • Page 8

    8 C417M-L (7/03) SPECIFICA TIONS Cable Entry: 2 explosionproof sealable fittings. Window: Ground and polished, fully tempered plate glass Window Viewing Area: EHX4E 3.19 in. (8.10 cm) diameter EHX6E 3.00 in. (7.62 cm) diameter EHX6E-16 3.00 in. (7.62 cm) diameter EHX8E 4.25 in. (10.80 cm) diameter Window Thickness: EHX4E 0.475 in. (1.21 cm) thick E[...]

  • Page 9

    C417M-L (7/03) 9 Figure 2. EHX*E Series Dimension Drawing Certifications and Ratings: Classified by Underwriters Laboratories Inc. as to explosion and fire hazard only T ype 4X enclosure for use in hazardous locations Class I, Groups C and D – Class II, Groups E, F , and G Class I, Zone 1, AEx d IIB, Ex d IIB 03 A TEX 0318166U 0035 II 2 G EEx d I[...]

  • Page 10

    10 C417M-L (7/03)[...]

  • Page 11

    C417M-L (7/03) 11 REVISION HISTORY Manual # Date Comments C417M-I 7/97 Rev. I. Updated manual to new for mat. Revised installation instructions and added assembly drawings to show all new enclosures, which were redesigned by Engineering to meet additional and more stringent standards for global certification. Model numbers changed. 9/97 Added servi[...]

  • Page 12

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ®[...]