Parker Hannifin 60 Series manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Parker Hannifin 60 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Parker Hannifin 60 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Parker Hannifin 60 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Parker Hannifin 60 Series should contain:
- informations concerning technical data of Parker Hannifin 60 Series
- name of the manufacturer and a year of construction of the Parker Hannifin 60 Series item
- rules of operation, control and maintenance of the Parker Hannifin 60 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Parker Hannifin 60 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Parker Hannifin 60 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Parker Hannifin service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Parker Hannifin 60 Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Parker Hannifin 60 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Pneumatic Actuators Catalog 4123-P A Revised, March 2000[...]

  • Page 2

    Introduction Parker 60 Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality engineered to provide high torque outputs and a high cycle, trouble-free life. A compact, dual opposed rack and pinion design and guide band suspension combine to produce a symmetrically balanced,[...]

  • Page 3

    Dimensional Data for 62, 63, 64, 65, 66, 68 and 69 Models 61S Actuator 61 Actuator ( ) Denotes dimensions in millimeters Dimensional Data for 61 and 61S Models AB C D E F Single Mount Dual Mount Model Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm 62AD 6.26 159.0 - - 4.17 105.9 3.15 80.0 1.26 32.0 2.91 73.9 3.15 80.0 62AC/O - - 6.77 172.0 [...]

  • Page 4

    Model Shown: 4Z-B6LJ-V -SS-61AC-2 Recommended Actuators for B, MB, and HB Series Ball V alves* Valve A B * C * D * E * Series Inch mm Inch mm Inch mm Inch mm Inch mm B2 2.23 56.6 B6 2.49 63.2 B8 2.91 73.9 MB2 2.33 59.2 1.61 40.9 0.80 20.3 0.75 19.1 1.50 38.1 MB4 2.33 59.2 MB6 2.48 63.0 HB4 2.70 68.6 SB8 2.94 74.7 SB12 3.03 77.0 SB16 3.27 83.1 N/A N[...]

  • Page 5

    Suggested Actuators for SB Series Ball V alves Actuators were sized in this table using the maximum allowable pressure dif ferential across the seats with a 1.20 multiplier for application factor . Please determine, by reading page 6, if the media or service conditions would render the information in this table questionable. Actuators for SB Series[...]

  • Page 6

    Determination of V alve T orque By properly sizing an actuator to a valve for a specific application, performance is guaranteed and economies are gained. Before an actuator can be sized for an application, the amount of torque required must be determined. The operating torque of a ball valve is influenced by the design, seat material, and applicati[...]

  • Page 7

    SB Series Pressure T orque Curves: T wo-way (L) and Three-way (XD) Diverter V alves T Seats RT Seats PF Seats PKP Seats UPE Seats DE Seats PTFE Seats PF Seats UPE Seats SB Series Pressure T orque Curves: Three-way (X) Selector V alves 0 34 68 103 137 172 206 0 500 1000 1500 2000 2500 3000 Differential Pressure (bar) Differential Pressure (psig) T o[...]

  • Page 8

    90 ˚ Models (AC, AO, and AD) Performance Characteristics AD T orques AC and AO T orques 40 psig (2.8 bar) 60 psig (4.1 bar) 80 psig (5.5 bar) 100 psig (6.9 bar) Series in-lb Nm in-lb Nm in-lb Nm in-lb Nm 61 59 6.7 89 10.1 119 13.4 149 16.8 61S - - 45 5.1 59 6.7 75 8.5 62 109 12.3 165 18.6 220 24.9 276 31.2 63 205 23.2 309 34.9 413 46.7 518 58.5 65[...]

  • Page 9

    + Double acting only 180˚ Models (ACX AND ADX) Performance Characteristics ADX T orques ACX T orques Air T orque Spring Series Spring 40 psig (2.8 bar) 60 psig (4.1 bar) 80 psig (5.5 bar) T orque Set in-lb Nm in-lb Nm in-lb Nm in-lb Nm 61 2 - - 25 2.8 57 6.4 39 4.4 61S 2 - - 16 1.8 21 2.4 21 2.4 8 19 2.1 90 10.2 161 18.2 62 7.0 64 10 - - 60 6.8 13[...]

  • Page 10

    SB Series Actuator Sizing Examples EXAMPLE 1 V alve Desired: 24Z-SB24L-PF-T -SS Actuator Desired: Spring Return, Normally Closed Differential Pressure: 250 psig Minimum Air Supply Pressure: 80 psig Service: On-off Media: Raw W ater Calculation From the PF Seal Pressure-T orque graph on page 7: T orque at 250 psig = 170 in-lb Service Factor from pag[...]

  • Page 11

    W ARNING FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELA TED ITEMS CAN CAUSE DEA TH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigati[...]

  • Page 12

    Parker Hannifin Corporation Instrumentation V alve Division 2651 Alabama Highway 21 North Jacksonville, AL 36265-9681 Phone: (256) 435-2130 Fax: (256) 435-7718 www .parker .com/IVD Catalog 4123-P A, 20M, 03/00 INSTRUMENT A TION V AL VE DIVISION AN ISO 900 1 F A CILITY Accredited by the Dutch Council for Certification Quality Systems Registrars, Inc[...]