A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron M5-I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron M5-I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron M5-I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron M5-I should contain:
- informations concerning technical data of Omron M5-I
- name of the manufacturer and a year of construction of the Omron M5-I item
- rules of operation, control and maintenance of the Omron M5-I item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron M5-I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron M5-I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron M5-I.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron M5-I item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Fully automatic blood pressure monitor M5-I Int-5-1 Gebrauchsanweisung Seite 28 Istruzioni per l’uso Pagina 54 Gebruiksaanwijzing Pagina 15 Instrucciones de uso Página 67 Instruction manual Page 2 Mode d’emploi Page 41 The World Hypertension League M5-I EU representative / EU V ertreter Représentant UE / Rappresentante UE Representante UE / E[...]

  • Page 2

    M5-I 2 Important instructions for obtaining meaningful readings . . . . . . . . . . . . . . . . . . . . . . . .3 Y our blood pressure monitor: the benefits . . . . . . . . .4 Measuring your blood pressure . . . . . . . . . . . . .5 – 7 Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Failure, causes and rectificati[...]

  • Page 3

    English 3 • Important : Blood pressure measurement is not sui- table in cases of serious arteriosclerosis (hardening of the arteries). • The pulse display is not suitable for monitoring the frequency of cardiac pacemakers. • If you suffer from disorders of heart rhythm, known as arrythmia, you should only use this blood pres- sure monitor in [...]

  • Page 4

    M5-I ST ART ( ) button ON/OFF ( ) button Diastolic Blood Pressure Display Pulse Display Memory buton Systolic Blood Pressure Display Green area 4 OMRON M5-I is a compact, fully automatic blood pressure monitor . Operating on the oscillometric prin- ciple. It measures your blood pressure and pulse sim- ply and quickly . It contains an intelligent sy[...]

  • Page 5

    ➊ Prepare the unit Open the battery compartment and insert batteries. Ensure polarity (+/-) of the batteries is correct. Insert air tube to air jack (on the left side of the device). The cuf f must be airless. ➋ Switching on the unit When you press the ( ) button all the symbols on the display light up for approximately two seconds in order to [...]

  • Page 6

    M5-I 6 ➌ Fitting the cuff Wrap the cuf f around your bare left arm so that the green colored band (indicating the centre of the blad- der) is positioned 2 – 3 cm above your elbow joint on the inside of your arm (see picture). Important! If you push up your sleeve, ensure it does not constrict the blood flow in your arm. Close the cuff with the [...]

  • Page 7

    English 7 ➎ The measurement starts When the target inflation value is reached, the air is auto- matically released. The value in the display counts down- wards. As soon as the monitor detects your pulse the ( ) sym- bol begins to flash. When the monitor no longer detects your pulse whilst the cuff pressure is dropping, your systolic and diastolic[...]

  • Page 8

    M5-I 8 • Avoid eating and drinking (alcohol, caf feine), smoking and sport before measuring your blood pressu- re, as these activities influence your blood pressure values. • Measurement must be carried out calmly and without rushing. It is recommended to check your blood pressure at least twice a day , once in the morning after getting up and [...]

  • Page 9

    English 9 Failure and their possible causes Incorrect measurement is indicated by E 1. A correct reading could not be obtained because measurement was disturbed by movement of the body . 2. The cuff is not fitted correctly . 3. Y our clothing has constricted your blood flow . 4. There is still air in the cuff when the monitor is switched on. 5. Und[...]

  • Page 10

    M5-I 10 • For cleaning the monitor only use a soft, lightly moi- stened cloth. Do not use petroleum spirits, thinners or similar solvents! • Stains on the cuff can be carefully removed using a moist cloth and soapy water . Do not wash the cuff or make it wet! • Keep your blood pressure monitor in the storage case to protect it from dust and m[...]

  • Page 11

    Model: OMRON M5-I Display: LCD digital display Blood Pressure Pressure: 40 mm Hg to 280 mm Hg Measurement Range: Pulse: 40 – 180/min. Accuracy: Pressure: ± 3 mm Hg Pulse: ± 5% of reading Inflation: Fuzzy-Logic controlled by electric pump Deflation: Automatic pressure release valve Pressure Detection: Capacitive pressure sensor Measurement Metho[...]

  • Page 12

    M5-I 12 Calibration The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. It is generally recommended to have the monitor ins- pected every two years to ensure correct functioning and accuracy . Please consult your authorised dealer or the OMRON Customer Service at the address given on the pa[...]

  • Page 13

    English 13 Some useful information about blood pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle. The highest pressure in the cycle is called the SYSTOLIC BLOOD PRESSURE; the lowest is t[...]

  • Page 14

    M5-I 14 What Causes High Blood Pressure? Blood pressure is only classed as high if it doesn’t go down when you rest. Permanently raised blood pres- sure can be caused by several factors such as hardening of the arteries, smoking or drinking too much alcohol. It can also be caused by cholesterol, a type of fat, building up inside your blood vessel[...]