Omron INTELLISENSE HEM-705CP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omron INTELLISENSE HEM-705CP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omron INTELLISENSE HEM-705CP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omron INTELLISENSE HEM-705CP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omron INTELLISENSE HEM-705CP should contain:
- informations concerning technical data of Omron INTELLISENSE HEM-705CP
- name of the manufacturer and a year of construction of the Omron INTELLISENSE HEM-705CP item
- rules of operation, control and maintenance of the Omron INTELLISENSE HEM-705CP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omron INTELLISENSE HEM-705CP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omron INTELLISENSE HEM-705CP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omron service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omron INTELLISENSE HEM-705CP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omron INTELLISENSE HEM-705CP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    A utoma tic Blood Pr essure Monit or with Prin ter Model HEM-705CP INSTRUCTION MANU AL R ENGLISH ESP AÑOL HEM-705CP-IM-US 7/19/05 9:26 AM Page 1[...]

  • Page 2

    TITLE 2 TITLE T ABLE OF C ONTENTS Bef or e Using the Monitor Introduction ........................................................................................ 3 Important Safety Notes ....................................................................... 4 Before T aking a Measurement ...........................................................[...]

  • Page 3

    INTRODUCTION 3 Thank you for purchasing the Omron ® HEM-705CP Intellisense ® Automatic Blood Pressure Monitor with Printer F ill in for futur e ref erence DA TE PURCHASED: ______ SERIAL NUMBER: ________ Staple y our purchase rec eipt here . Y our ne w digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This[...]

  • Page 4

    4 IMPORT ANT SAFET Y NO TES T o assur e the corr ect use of the pr oduct basic safety measur es should always be followed including the pr ecautions listed below: þ Read all information in the instruction book and an y other literature included in the box before using the unit. þ Contact your physician for specif ic information about your blood p[...]

  • Page 5

    BEFORE T AKING A MEASUREMENT 5 T o ensure a reliable reading follow these recommendations: 1. A void eating, smoking, and e x ercising for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A void taking measurements during stressful times. 3. Measurements should be t[...]

  • Page 6

    TITLE TITLE KNOW Y OUR UNIT ST AR T Button Paper Feed Pulse Rate Print Graph Date/T ime Display Heart Symbol Air T ube Memory Button S ystolic Blood Pressure ON/OFF Button Set Date/T ime Adjust Date/T ime Diastolic Blood Pressure Print All Data Print Current Data/Stop Printing Printer Cov er Air Plug (Connects to Air Jack) Main Unit: C omponents: A[...]

  • Page 7

    TITLE TITLE BA T TERY INST ALL A TION/REPLA CEMENT 1. Press the ▼ OPEN indicator on the battery co ver and slide the cov er of f in the direction of the arro w . 2. Install 4 “ AA” size batteries so the + (positi v e) and - (neg ati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery co ver . Ma[...]

  • Page 8

    TITLE 8 TITLE C ONNEC TING THE PRINTER 1. Remov e the printer cord from around the printer unit. 2. Connect the printer to the blood pressure monitor . Insert the cable plug with the indicator facing upw ard. CA UTION: Inserting the cable plug in an y other position will damage the monitor . HEM-705CP-IM-US 7/19/05 9:26 AM Page 8[...]

  • Page 9

    9 L O ADING THE PRINTER P APER This printer uses OMR ON ® thermal paper , part number 90TRP . Use only this thermal paper or thermal paper of similar size, width 38mm, roll diameter not to e xceed 26mm. NO TE: For information on where to purchase printer paper visit our website at www .omronhealthcare.com or call customer service at 1-800-634-4350[...]

  • Page 10

    SET TING THE D A TE AND TIME 10 The Blood Pressure Monitor automatically stores up to 28 measurement v alues with the date and time. Set the monitor to the current date and time before taking a measurement for the f irst time. If the current date and time is not set, a default date and time will display . 1. SETTING THE YEAR When the batteries are [...]

  • Page 11

    TITLE SET TING THE D A TE AND TIME 11 3. SETTING THE MONTH Press the ADJUST b utton to adv ance by increments of one month. Press the SET b utton to set the current month. The day flashes on the display . 4. SETTING THE D A Y Press the ADJUST b utton to adv ance by increments of one day . Press the SET b utton to set the current day . The hour flas[...]

  • Page 12

    TITLE 12 TITLE TITLE APPL Y ING THE ARM CUFF 1. Make sure the air plug is securely inserted in the main unit. 2. Remo ve tight-f itting clothing from your upper arm. 3. Sit in a chair with your feet flat on the floor . Place your arm on a table so the cuf f is le v el with your heart. APPL YING THE CUFF ON THE LEFT UPPER ARM 4. Put your arm through[...]

  • Page 13

    5. Pull the cuf f so the top and bottom edges are tightened e v enly around your arm. 6. When the cuf f is positioned correctly , press the se wn hook material FIRML Y against the pile side of the cuf f. 7. Make certain the cuf f fits snugly around your arm. The cuf f should make good contact with your skin. NO TE: Y ou should be able to fit your i[...]

  • Page 14

    TITLE 14 TITLE TITLE T AKING A MEASUREMENT The monitor automatically determines your ideal inflation le v el. In rare circumstances when a higher inflation may be necessary , the monitor automatically re-inflates the cuf f up to 30mmHg higher than the initial inflation and restarts the measurement. The monitor detects the pulse during inflation. Do[...]

  • Page 15

    15 TITLE TITLE TITLE T AKING A MEASUREMENT ST ART 4. When the measurement is complete, the arm cuf f completely deflates. Y our blood pressure and pulse rate are displayed. 5. Pr ess the ON/OFF button to turn the monitor of f. NO TE: The monitor will automatically turn of f after f i ve minutes. INSTR UCTIONS FOR SPECIAL CONDITIONS If your systolic[...]

  • Page 16

    Every time you complete a measurement the monitor store s t h e b l o o d pressure and pulse rate in the memory . The Blood Pressure Monitor automatically stores up to 28 measurement v alues. When 28 sets of measurement v alues are stored in the memory , the oldest record is deleted to sa ve the most recent measurement v alues. T O DISPLA Y THE MEA[...]

  • Page 17

    17 TITLE TITLE USING THE PRINTER The HEM-705CP printer unit has the capability to print all the of measurement v alues stored in the memory of the Blood Pressure Monitor . NO TES: • The correct date and time must be set up on the monitor before taking a reading. If the date and time is not set, the numerical v alues will not appear on the print o[...]

  • Page 18

    TITLE 18 TITLE USING THE PRINTER 2. T O PRINT ALL THE MEASUREMENT V ALUES Pr ess the ALL D A T A button. The numeric printout will list all of the readings stored in the memory starting with the oldest reading to the most recent reading follo wed by the a verage of all the stored readings. The stored data will print as illustrated in the follo wing[...]

  • Page 19

    19 TITLE TITLE USING THE PRINTER 3 . T O PRINT A GRAPH OF ALL MEASUREMENT V ALUES Pr ess the GRAPH button. The graph will list all of the readings stored in the memory . The stored data will print as illustrated in the follo wing e xample: 50 1 00 1 5 0 2 00 mmHg 3-6 Diastolic Reading Systolic Reading A v erage systolic reading of stored measuremen[...]

  • Page 20

    TITLE TITLE CARE AND MAINTENANCE T o keep your digital blood pr essur e monitor in the best condition and pr otect the unit fr om damag e follow the dir ections listed below: • K eep the monitor in the storage case when not in use. • Do not f or cefully bend the arm cuf f or air tube. Do not fold tightly . • Clean the monitor with a soft dry [...]

  • Page 21

    21 TITLE TITLE TITLE ERROR INDICA T ORS SY MBOL CA USE C ORREC TION Monitor did not detect pulse rate Remov e the arm cuf f. Refer to “ Applying the arm cuff” on page 12. W ait 2-3 minutes. T ake another measurement. Cuf f under -inflated Remove the arm cuf f. Read “T aking a Measurement” on page 14. W ait 2-3 minutes. T ake another measure[...]

  • Page 22

    TITLE 22 22 TITLE TITLE TROUBLESHOO TING TIPS PROBLEM CA USES SOL UTIONS No po wer . W orn batteries Incorrect battery installation Replace all 4 "AA" batteries. Reference page 7. Check the battery installation or proper placement of the battery polarities. No data will print. Printer not connected Cable plug not inserted correctly or dam[...]

  • Page 23

    QUICK REFERENCE GUIDE T o ensure a reliable reading, av oid eating, smoking, and e xercising for 30 minutes before taking a measurement. Y ou should try to measure your blood pressure at the same time each day . A v oid taking measurements during stressful times. 1. Remov e an y tight-f itting clothing from your upper arm. 2. Sit in a chair with yo[...]

  • Page 24

    QUICK REFERENCE GUIDE 24 5. Press the ON/OFF b utton. Display symbols appear . 6. Press the ST AR T b utton. The cuf f starts to inflate automatically . Remain still and do not talk during the measurement. NO TE: T o stop the inflation or measurement, push the ST AR T/ST OP b utton. The monitor will stop inflating, start deflating, and will turn of[...]

  • Page 25

    25 TITLE TITLE TITLE FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital de vice, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection ag ainst harmful interference in a residential inst[...]

  • Page 26

    TITLE 26 TITLE W ARRANTY Y our HEM-705CP , IntelliSense Automatic Blood Pressure Monitor , excluding the monitor cuf f, is warranted to be free from defects in materials and w orkmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor . The monitor cuf f is warranted to be [...]

  • Page 27

    NO TE: These specif ications are subject to change without notice. 27 TITLE TITLE SPECIFICA TIONS Model: HEM-705CP Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg Pulse: 40 to 180/minute Ac curacy/Calibration: Pressure: ±3 mmHg Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Acti ve electronic contro[...]

  • Page 28

    Made in China Manufactured by OMR ON Distrib uted by: OMR ON HEAL THCARE, INC. 1200 Lak eside Dri ve Bannockb urn, Illinois 60015-1243 www .omronhealthcare.com © 2005 OMR ON HEAL THCARE, INC. 705CPINST Re v B HEM-705CP-IM-US 7/19/05 9:26 AM Page 28[...]