A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Omega DPS3200, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega DPS3200 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Omega DPS3200. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Omega DPS3200 should contain:
- informations concerning technical data of Omega DPS3200
- name of the manufacturer and a year of construction of the Omega DPS3200 item
- rules of operation, control and maintenance of the Omega DPS3200 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega DPS3200 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega DPS3200, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega DPS3200.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega DPS3200 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    http://www.omega.com e-mail: info@omega.com Ome ga.com Ome ga.com Ome ga.com Ome ga.com TM TM TM TM DPS3100 & DPS3200 series Programmable Scanners[...]

  • Page 2

    TABLE OF CONTENT S Page 1 SPECIFICATIONS ................................................................................................................. ............................................... 3 DESCRIPTION .....................................................................................................................................[...]

  • Page 3

    TABLE OF CONTENT S Page 2 Electro-Mechanical Relay Option ................................................................................................ .................................... 20 Figure 2. Elect ro-mechan ical Relays Hooku p Exampl e ............................................................................. .................. 20 [...]

  • Page 4

    Page 3 SPECIFICATIONS (Typical @ 25C and rated supply voltage unless otherwise s pecified) STANDARD INPUTS * 4- 20m a 10-50m a 0- 5Vdc 0-10Vdc * Therm ocouple inputs: J,K,T,E,R,S,B * Cold junction com pensation error: +/- 1C (10C to 40C) * Open in put indication: HELP display ed * Tem perature displayable in Degrees C or F * Non stand ard input s a[...]

  • Page 5

    Page 4 DESCRIPTION DPS3000 Series instrum ents are m ulti-channel s canners th at pack a number of functions in to one unit. Tasks that require mu ltiple monitors can n ow be accom plished by usin g only a single un it. Signals from a nu mber of diff erent transducers can be bro ught into scre w ter minal s t ha t are conve ni ently loc a ted o n t[...]

  • Page 6

    Page 5 DISPLAYING PARAMETERS DPS3000 Series k eeps track of v arious paramet ers and these m ay be dis play ed by push ing appropriate k eys on the fron t panel. The parameters that are tracked are: a) Channe l's high pea k d) Cha nnel with the lo west read ing b) Chan nel's low peak e) Process deviation of each ch annel from pre-programm[...]

  • Page 7

    Page 6 setpoint, dif ference betw een any two selected chann els or just run as a tim er. In the timer m ode the unit keeps track of process run time with crystal controlled accuracy . Elapsed Time display format is 'HH.MM.SS' for hour s, minutes, a nd seco nd s. T he d esire d d i spla y mode is sele cted dur i ng SYS SE TU P ---- ( fo r[...]

  • Page 8

    Page 7 Display tim e for each chann el is programm able from 1- 999 seconds (16.65 m in.). This is usef ul for adjusting dis play tim e to a rate w hich is con sistent with the type of process being m onitored. Scan time for each channel is independent of display tim e. This permits programm ing long display tim es with o ut losing track of the pro[...]

  • Page 9

    Page 8 a) The first one is a mom entary display in w hich the deviation is indicated for a short tim e. Fo llo win g this brief display tim e, the unit reverts to its normal m ode o f op eratio n (scannin g, differential, timer etc.). To achieve this, f irst select th e channel w hose setpoin t deviation is des ired. T his is done by pushing the CH[...]

  • Page 10

    Page 9 Once the correct pass -code has been entered, th e display s hows 'SYS CH' , w ith 'CH' blinki ng. At this p oint t he ope rato r may choose b etween making channe l settings ( C H ) , or system settings (SY S ) . Use ^v key to togg le between CH and SYS m odes. When t he desired mode i s blin king , press SETUP key to be[...]

  • Page 11

    Page 10 CHANNEL CONFIGURATION After en tering correct pass-code and s electing the blinkin g 'CH' (ref. SETUP section), the display show s 'SLCt CH' (for "Select Channel"). Use ^v key to display the desired channel. Selected chan nel will be displayed in the form at 'CHANEL x' (wh ere x=channel #). Once the d[...]

  • Page 12

    Page 11 key an d then pushing it again w ill decrement the v alue ( ^v key w orks as a togg le -- altern ating between increm ent and decremen t). T o change the n ext digit f irst push the <NEXT> key . T his w ill ad vance the f lashing to the f o llo win g digit. Use ^v key to chang e the value. A fter the desired High Scale setting is d is[...]

  • Page 13

    Page 12 SETPOINT value. Once the desired SETPOINT value is displayed, push SETUP key to enter that value and go on to setup ch annel 1's operational m ode. Setup for Unive rsal Relay (Channel 1 Relay) Chann el 1 relay can be conf igured to work as a universal relay or as Channel 1 relay only . In universal m ode, this relay gets activated w he[...]

  • Page 14

    Page 13 Setup For Engineering Units After settin g a channel's relay for NORMALLY OPEN/CLOSED operation, the nex t parameter to be set are the 3 letters that follow the pr o cess value in th e display. These 3 letters represent the measurem ent units for that particular chan nel. Any desired combination of the follow ing letters may be p rogra[...]

  • Page 15

    Page 14 Example #2: Use of the LOW SCALE Param eter Setup f or a 4-20ma tran sducer si gnal correspondin g to 500-2000 degrees F ahrenheit tem perature i.e. 500 degrees at 4ma and 2000 degrees at 20m a (one degree res o lution): DECIMA L POINT = 9999 HIGH SCAL E = 2000 LOW SCA LE = 500 OFFSET = 4.00 TARE = 0.000 Example #3: Use of the TARE Paramete[...]

  • Page 16

    Page 15 Setup For Relay Latch/Non-Latch After settin g DISP LAY TIME, the next parameter determ ines wheth er the output relays w ill operate in a Latched or Non- Latch ed mode. Relay Latched Mode: In this m ode the relay is activ ated when its L IMIT value is exceeded an d stays activated until the operator m anually resets the relay. To manually [...]

  • Page 17

    Page 16 desired va lue is display ed, push SETUP key to enter that value and go to the nex t step. Voltage Range Setup (for millivolt inputs) For Millivolt input units, the display f irst shows 'HV rnGE ' (for " Hi gh V olta ge Range " ). After the High Vo ltage range is set, the display show s 'LV rnGE' (for "Low[...]

  • Page 18

    Page 17 PEAKS A very useful fun ction of DPS3000 is tracking th e highest (peak ) and the low est (valley ) point attained by each ch annel. This is particularly helpful if an ope ratio n is not being constantly w atched or is left u nattended (e.g. overnig ht). Since high and low points for each chann el are mon itored and stored separately , the [...]

  • Page 19

    Page 18 DPS3207 7 Channel Unit DPS3204 4 Channel Unit ENTER PA SSC ODE - - 3254 SYS CH SELECT CHANNEL IP TYPE DISPLAY OPTION (Select one) ELAPSED TIME SCAN HIGH CHANNEL LOW CH ANNE L DISPLAY DEVN. CHANNEL DIFF. DISPLAY TIME RELAY L AT CH/NON-LATCH AUDIO AL ARM ON/OFF COLD JUNCTION CH. CALIBRATI ON VOLTAGE RANGE CURRENT RANGE VOLTAGE CURRENT ‘J’[...]

  • Page 20

    Page 19 DPS3107 7 Channel Unit DPS3104 4 Channel Unit ENTER PA SSC ODE - - 3254 SYS CH SELECT CHANNEL IP TYPE DISPLAY OPTION (Select one) ELAPSED TIME SCAN HIGH CHANNEL LOW CH ANNE L DISPLAY DEVN. CHANNEL DIFF. DISPLAY TIME RELAY L AT CH/NON-LATCH AUDIO AL ARM ON/OFF COLD JUNCTION CH. CALIBRATI ON VOLTAGE RANGE CURRENT RANGE ‘J’ T /C CR.AL T/C [...]

  • Page 21

    Page 20 RATE DPS3000 series tracks th e rate of process change /min ute for each chann el. This rate is displayed by first push ing the CH. SEL key to select the chann el wh ose rate is desired. Once the channel has been selected, push rate key. The display will briefly read ' cx-rate' (x=chan nel #), and then the m onitored rate for that[...]

  • Page 22

    Page 21 NOTE: LOOK UNDER SPECIFICAT IONS FOR THE RATING ON REL AY S AND OPEN COLLECTOR OUTPUTS. UNDER NO CONDITION SHOULD THE RELAYS AND OPEN COLLECTOR OUTPUTS BE OPERAT ED BEY OND THEIR RATED CAPACIT Y. DOING SO CAN DAMAGE THE UNIT PER MANENTLY. The status of the relay s for all the ch annels is indicated on th e front panel by a row of LEDs. When[...]

  • Page 23

    Page 22 1 2 3 4 6 5 7 8 9 10 11 12 13 14 OUTPUT CONNECTOR PIN ASSIGNMENT - + - + - + - + - + - + - + Table 1. DPS3000 Ser ies Output Con nector Pin Ass ignm ents OUT-PUT CONNECTOR P IN ASS IGNMENTS Pin # Signal Relay Outp ut Open Collector 1 Chann el # 1 Limit Comm on Positive Output 2 Channel #1 Lim it Normally Op en/Closed * Negative Output 3 Cha[...]

  • Page 24

    Page 23 TROUBLE SHOOTING If the m eter lo cks on a particular display, unplug and plug in again to unlock the display. A total reset defaults all scaling values to zero. To perform this reset, re-apply power w ith RESET key pressed in. Factory Channel settings: To obtain factory preset valu es sim ply re-a pply pow er w ith ^v key pressed in. Facto[...]

  • Page 25

    Page 24 MOUNTING 3.70” (94m m ) 4.05 ” (10 2.87 mm) 1.77” ( 4 5 mm) 0.15” dia. (3.81m m ) Figure - 4. Panel Cutout and mounting hole dim ensions 1. Cut out P ane l and mounti ng ho le d imensions a s shown in the figur e 8. 2. Remove the nut s from the mounti ng sc rews on the P anel Mete r. 3. Insert panel m eter into the hole until it is [...]

  • Page 26

    Page 25 WARRANTY For Warranty inform ation, check Om ega’s w eb site at ht tp : / / www. o me ga . c o m[...]

  • Page 27

    Page 26[...]

  • Page 28

    Page 27[...]

  • Page 29

    Page 28[...]