Newcon Optik LRB 20 000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Newcon Optik LRB 20 000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Newcon Optik LRB 20 000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Newcon Optik LRB 20 000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Newcon Optik LRB 20 000 should contain:
- informations concerning technical data of Newcon Optik LRB 20 000
- name of the manufacturer and a year of construction of the Newcon Optik LRB 20 000 item
- rules of operation, control and maintenance of the Newcon Optik LRB 20 000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Newcon Optik LRB 20 000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Newcon Optik LRB 20 000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Newcon Optik service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Newcon Optik LRB 20 000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Newcon Optik LRB 20 000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operation Manual LRB 20 000 LONG RANGE LASER RANGE FINDER BINOCULAR In USA: 3310 Prospect A ve. Cleveland, OH 44115 In Canada: 1183 Fi nch A ve. W ., Sui te 302, Toronto, ON M3J 2G2 Canada IMPORTANT INFORMATION Read prior to activation You have just purchased a comp licated electronic dev ice. To operate it properly, please read this m anual carefu[...]

  • Page 2

    Features of the LRB 20 000 Laser Range Finder B inoculars • Digital D ata Output • First or Last Target I ndication • Built- in Com pass • Li ght We igh t • Rugge d • Meet all Military Specifications CONTENTS 1. Brief description 2. Purpose 3. Technical characteristics 4. Supplied accessories 5. Appearance of the device 6. Safety precau[...]

  • Page 3

    - inspect the ran ge finder exterior f or physical dam age (no cracks, dents, deep rust are adm itted); - check th e dehydrator for w orking condition. If the silica g el is pink in color, replace it with the n ew one taken from indiv idual SPTA se t (item 11.6.3); - place the battery in operation as directed in Section 16 of Operating instructions[...]

  • Page 4

    2. PURPOSE 2.1. Binoculars range finde r LRB 20 000 AEP 36.28.001 is a device of industrial- technical purpose and designed for ground surveillance, observ ation of individual targets and m easurement. 2.2. The range finder com plete with the Angular Mount is designed for referencing ground location point by the predetermined landm ark coordinates [...]

  • Page 5

    EM ITTER : Ambient temperature Parameter –40 ˚ C norma l conditions 50 ˚ C 1. Minimum operating pumping voltage U oper. min . , V, max 2. Maxim um operating pu mping voltage U o per.max. , V, m ax 3. P umping vol tage t empera ture coefficien t ТКН n , V/ ˚ C 4. Capacity of storage capaci- tors C c of em itter test set, F – – – – CO[...]

  • Page 6

    Table 4.1, continued Description Designa tion Qnty Serial No. Remar ks 19. Cable 20. Eraser 21. Cloth 22. Chargi ng devic e 23. Protection dev ice Materials 24. Silica gel, indicating GOST 8984-75 Package 25. Package 26. Package 27. Package 28. Casin g 29. Casin g 30. Cover 31. Cover 32. Cover Documents 33. Operating instru ctions AEP 48.44.120 G61[...]

  • Page 7

    Connector X1 coupl es the contr ols and the Recha rgeable battery to control c ircuit boar d (A1). C1 and C2 are energy storage capacitors p laced in the pu mping circ uit. The y a re charg ed up to 700-1000 V t hrough a speci al contact designa ted A on control c ircuit boar d A1. Capacitor C3 and diodes V1, V2 are placed in the p umping circuit t[...]

  • Page 8

    6. SAFETY P RECAUTIONS 6 .1. Range finder is an opto-electronic device em itting h igh- densit y puls es of dark li ght at w avelen gth of 1.06 µm, characteri zed by the follow ing dan gerous f actors according to GOST 12.1. 040-83: - direct laser radiation; - m irror-reflected las er radiation; - diff use-reflected las er radiation. Direct and m [...]

  • Page 9

    7. PREPARI NG FOR USE 7.1. Choos e an observat ion post. 7.2. Rotate the objective frame to bring the reticle in sharp focus. 7.3. Check range fi nder for proper operation: - battery v oltage; - the r ange find er fo r p rop er functio ning. 7.3.1. To analyze the battery v oltage, set the ON- OFF selector switch to the ON position and check if th e[...]

  • Page 10

    7.5.2 . T o o rient the ra nge find er b y using the re fere nce di rec tiona l angle , proceed as follow s: - Binocular the ran ge finder on the reference point whos e dir ectio nal angl e has b een known; - rotate the azimu th dial to set the reference directional angl e; - turn the clam ping handle to lock the azim uth dial in position. With the[...]

  • Page 11

    To make sure th at the needle is free f rom defects, ch eck that: - the needle oscillates in a sm ooth and uniform man ner to regain balance; - the position of the needle end is the sam e relative to the mark when the needle settles; - th e needle ends are level w ith the m arked plates w ithin ± 0.5 m m. The compass n eeds triple checking . If ev[...]

  • Page 12

    - as the readines s indicator comes on, aim th e range finder at an off- set point forw ard of the target; - as the target align s with h e reticle gap, release the MEAS URE 1 (MEASURE L) button; - read the m easured range. 8.5. To take azimuth and magn etic azimuth meas urements, proceed as follows: - align the v ertical mark of th e Binocular obj[...]

  • Page 13

    - - calculate from the determined magnetic azimuth A m of the reference point and the target to find the directional ang les, reckoning in the com pass correction ∆ A obt ained from the form ula: α = A m – ∆ A m Read the com pass correction ∆ A m of th e map; - note dow n the reference poin t target directional ang les on the plottin g boa[...]

  • Page 14

    9. SERVICEABILI TY TEST The principal tests to be performe d on the rang e finder are lis ted below . T a b l e 9 . 1 What is checked , too ls, inst ruments, equipm ent. Tes t procedure Tec hnical require ment 1. Range finder completeness 2. Range finder exterior 3.Exterior of range finder optical parts (to be checked visually). Make sure the unit [...]

  • Page 15

    10.2. Maintenance Service Types and I ntervals. 10.2.1. While in use, the range finder is subject to the following ty pes of maintenance services: - check inspection; - daily (routine) service; - in- service m aintenance. 10.2.2. The same serv icing intervals are established for the component parts and the entire rang e finder. Check inspection is [...]

  • Page 16

    Table 10.2 Operatio ns Pro cedure as per Materials, to ols and accessories 1. Servicing w ithin check ins pection scope 2. Cle aning r ange finder to rem ove dust, dirt an d moistu re 3. T o uching up p ain- ted exterior of range finder (when so required) 4. Dryi ng and repair of straps (wh en so required) 5. Replacing s ilica gel (when so re- quir[...]

  • Page 17

    10.6.1. To clean the contacts in the battery section, do the following : - w ind som e cotton w ool around one end of a wooden stick; - m oisten the cotton wool w ith alcohol; - w ipe the contacts s everal times by m eans of cotton w ool moistened w ith alcohol. 10.6.2. T o remove du st and dirt from the optical surf aces, use the brush 23 and clea[...]

  • Page 18

    11.2. The problems lik ely to occur in the range fi nder are listed w ith their causes an d remedies below in Table 11.1 Table 11.1 Possible proble ms Probable ca use Rem edy 1. Picture bl urred in right -hand eyepiece 2. Readiness indica- tor remain s dark after depress ure of MEASUR E 1 (MEASURE L ) button 3. Red gl ow is obser- ved in indicator [...]

  • Page 19

    - protection device 12 , used t o supp ly the ra nge finde r with (27±2.7) V DC or 22- 29 V from a v ehicle elect rical sy stem, or w ith 22-29 V or 12-14.5 V f rom ext ernal batteries ; - cable 14 , used to couple the protec tion dev ice to the electrical sy stem of a track -lay ing vehicle; - cable 15 , used to connect th e prot ection device to[...]

  • Page 20

    This is provided by arranging the pack ing case so that the arrow mark ed on top points North. Charged batteries may be stored together with the rang e finder unit for up to three months. 13.3. The range finder placed in short- term storag e (up to 3 months) is subject to inspection as directed in Section 11.5 and Long Term Storage as directed in S[...]

  • Page 21

    - discharged by setting the toggle sw itches to the DISCHARGE and MAIN positions until the DISCHARGED lig ht emitting diod e flashes on and off to indicate the discharg ed conditio n. Charg e up the operating voltag e for 15 hours as directed under 16.3.1. 15.3.3. The battery that has been stored in th e disch arged condition for over 3 month s is [...]

  • Page 22

    16. DATA OUTPUT TO EXTERNAL EQUIPM ENT T he data on measured range is output to a remote display or compu ter across connector X2. To o utput the data, it is necessary to apply the supply voltage of 3 to 8 V from the equ ipment to be co nnected to the ran ge finder to pin 9 of connector X2. The amplitude of the output sig nals w ill depend on the v[...]

  • Page 23

    18. LONG TERM STORAGE CERTIFICATE Binocu lars rang e finder L RB 20 000 AEP 36.28.001, Serial N o. ___________________________ , has been preserv ed. Date of L ong Term Storage ____________________ Name an d grade of preserv ative_________________________ Long Term Storag e period _____________________ Preserved by ___________________________ Accep[...]

  • Page 24

    20. WARRANTY NEWC ON OPTIK warrants this product against defects in material and work manship for one y ear from the date of the original date of consum er's purch ase, but no m ore than 18 months from the date of m anufacturing. Should y our Newcon product prove defectiv e during this period, please bring the product securely pack aged in its[...]

  • Page 25

    Laser range finder binoculars LRB 20 000 1 - range finder; 2 - Ang ular Mount; 3 - tripod Fig. 1 Range finder (v iewed on the side of eyepiece) 1 - housing; 2 - MEASURE 1 a nd MEASURE L buttons; 3 - belt; 4 - panel; 5 - ILLUMINA TION toggle switch lever; 6 - Binocu lar eyepiece; 7 - screw; 8 - indi cator eyepiece; 9 -plug МР -1; 10 - battery sect[...]

  • Page 26

    Angular Mount 1 - adjustm ent knob; 2 - leve r; 3 - bracket; 4 - retainer; 5 - scale; 6 - framed lens; 7 - adjustm ent knob; 8 - com pass; 9 - nut M8; 10 - framed lens; 11 - knob; 12 - support; 13 - le vel УК -10; 14 – azim uth circle; 15 – body Fig. 4 Tripod mount 1 - mounting head; 2 - base; 3 - leg; 4 - nut Fig. 5[...]

  • Page 27

    Indiv idual SPTA set 1 - Rechargeable batt ery 10D-0,55 С -1 ; 2 - f use link VP1-1 1,0 А 250 V; 3 - pencil; 4 - se aling ring; 5 - ey e shield; 6 - fram ed lens; 7 - cloth; 8 - eraser; 9 - wrench; 10 - coordinate c onverter; 11 - charging device; 12 – protection device; 13 - indicating silic a gel; 14 throug h 18 - cable; 19 - me mbr an e ; 20[...]