A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Newcon Optik LAM 10M IR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Newcon Optik LAM 10M IR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Newcon Optik LAM 10M IR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Newcon Optik LAM 10M IR should contain:
- informations concerning technical data of Newcon Optik LAM 10M IR
- name of the manufacturer and a year of construction of the Newcon Optik LAM 10M IR item
- rules of operation, control and maintenance of the Newcon Optik LAM 10M IR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Newcon Optik LAM 10M IR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Newcon Optik LAM 10M IR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Newcon Optik service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Newcon Optik LAM 10M IR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Newcon Optik LAM 10M IR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Operation Manual LAM 10M IR LASER AIMING MODULE / TARGET POINTER 105 Sparks Ave., Toronto, ON, M2H 2S5, Canada[...]

  • Page 2

    [...]

  • Page 3

    IMPORTANT INFORMATION Read prior to activation You have ju st purchased a sophisticated el ectronic de vice. To operate it properly, please read this manual carefully. LAM belongs t o Class I laser products i n accordance wit h IEC 60825-1. Her e are some common precautions that must be observed. • ALWAYS turn the de vice off when it is not in us[...]

  • Page 4

    1 CONTENTS 1. Brief description ................................................. 2 2. Device design ..................................................... 3 3. DELIVERY S ET ................................................ 8 3.1. Standar d delivery set ...................................... 8 3.2. Optional parts.....................................[...]

  • Page 5

    2 Carefully read all the instructions prior to use. Failure to obey the instructions will void the warranty ! INVISIBLE LASER RADIAT ION CLASS I LASER PRODUCT 830–860 nm 0,1mW. 1. Brief description LAM 10M IR l aser aimer (her einafter referred as LAM) is designed for precise aiming at night time. LAM forms an IR laser radiation spot on the targe[...]

  • Page 6

    3 2. Device design 17 16 14 8 7 6 5 4 3 2 1[...]

  • Page 7

    4 Fig. 1. LAM 10M IR 1 – clamp 2 – bracket 3 – stopper 4 – remote connector 5 – body 6 – emitter 7 – emitter cap 8 – emitter protective cap 9 – windage adjustm ent 10 – fastener 11 – ‘laser on’ warnin g indicator 12 – elevation adjustment 13 – fixati on screw cap 14 – fixati on screw 15 – battery compartment cap 16[...]

  • Page 8

    5 LAM consists of an emitter (6,7, Fig.1), a battery compartment (15,16, Fig.1), wind age (9, Fig.1) and elevatio n (12, Fig.1) a djustment mechanism s, an operating m odes switch (17, Fig.1), a remote switch (Fig.2), a clamp (1, Fig.1). A battery is to be inserted into the battery compartment (16, Fig.1). Battery compartment cap (15, Fig.1) is att[...]

  • Page 9

    6 LAM automatically turns off after 30 minutes of being switched in positions C and R. I n order to act ivate LAM aft er it has automatically turned off, return the switch (17, Fig.1) into OFF position and then switch it to the desired position again. The remote switch (Fig.2) can be attached to LAM by a connector (3, Fig.2) with a union nut. When [...]

  • Page 10

    7 1 — key; 2 — velcro tape; 3 — connector Fig. 2. Remote switch 1 2 3[...]

  • Page 11

    8 3. DELIVERY SET 3.1. Standard delivery set LAM is supplied in the following assembly: Quantity, pcs LAM 10M IR 1 Remote switch 1 Velcro tape 2 O-Ring 1 Case 1 Manual 1 Battery CR123 1 3.2. Optional parts LAM can be supplied wit h a barrel mount.[...]

  • Page 12

    9 4. Specifications Laser wavelength 830…850 nm Beam divergence 0.5 mrad Spot size at 50 meters 25 mm Windage and elevation ad justment range ±20 mrad Windage and elevation adjustment step 0.5 mrad (50 mm @100m) Accuracy of adjustment after 1000 shots 0.1 mrad Accuracy of adjustment after 100 re- mountings on a rail 1 mrad Laser emitting p ower [...]

  • Page 13

    10 5. OPERATION INSTRUCTIONS 5.1. Installing the battery LAM is powe red by a sta ndard Lithi um CR123 3V battery . To install a battery: - unscrew the ba ttery compar tment cap (15, Fig. 1), - insert a battery observing the polarity as marked on the battery compartment, - check the condition of the O-ring on the body; replace it if worn or torn, -[...]

  • Page 14

    11 5.3. Connecting the remote c ontrol To connect the remote switch (Fig.2): - unscrew the ca p of the rem ote connect or (4, Fig. 1) and store it in a safe place, - plug in the rem ote connector c ontact (3, Fig. 2) observi ng the key visible on the cable side, - tighten the union nut, - attach the remote switch to the weapon pivot or grip with ve[...]

  • Page 15

    12 - remove protective cap (8, Fig. 1) from emitter tube output win dow; - activate LAM in mode C; - match the ce nter of radi ation spot wi th the aim ing mark by means of r otating ha ndwheels of adjustm ent mechanisms; - perform test firing with LAM under the same conditions as when checking th e weapon fire capability with an iron sight; - elim[...]

  • Page 16

    13 6. Maintenance, storage and transportation 6.1. General LAM is a sophisticated precise optical in strument equipped with electronics. Therefore, it should be handled with du e care. - Never disassem ble LAM. - Keep away from direct sunlig ht, im pacts, dust, moisture, and sharp changes of temperature. - Do not keep LAM at temperatures highe r th[...]

  • Page 17

    14 6.2. Storage To set LAM from com bat position into a stowed one: - turn LAM off (operati ng modes swi tch (17, Fig.1) shoul d be set to OFF position); - cover emitter tube output window with protective cap (8, Fig.1); - disconnect remote switch (Fig.2) from the weapon, l oosen screw caps (13, Fig.1), remove LAM wi th remote switch from Picatinny[...]

  • Page 18

    15 To apply new layer of lubricant: - Within two hours from cleaning apply an even 0.2-0.5 mm thick layer of lubricant on m etal surfaces with a brush. - Do not cover plastic parts. When preparing for a long-term storage LAM just recei ved from ma nufacturer or from workshop, ensure that actual set is the same as indicated in the Delivery Set secti[...]

  • Page 19

    16 - Cover aim er with protecti ve cap. - Disconnect the remote switch from the weapon. - Dismount L AM from Picatinny rail . - Pack LAM and remote switch into the case. When packed, LAMs ca n be transported by any covered means in accordance with storag e conditions as described in this manual. When in operation, LAM is to be tran sported in its c[...]

  • Page 20

    17 7. TROUBLESHOOTING Spot shape or size has chan ged Emitter objective lens is dirty. Flush emitter lens with fresh water and wipe it with soft cloth. No radiation when activating LAM with remote switch Turn the operating modes switch (17, Fig.1) to OFF position and then turn LAM ON again. If this doesn’t help, replace the remote switch. Radiati[...]

  • Page 21

    18 8. WARRANTY NEWCON OPTIK warrants this produc t against defects in material and workmanship for one year from the date of t he original dat e of consum er's purchase. S hould you r Newcon product pro ve defective du ring this pe riod, please bri ng the product securel y packaged in i ts original c ontainer or an equivalent, along with proof[...]

  • Page 22

    19 9. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult the enclo sed manual. If the problem remains unresol ved, contact our customer su pport departm ent at +1(416) 663-6963 or toll free at 1-877-368-66 66. Our operating hours are 9am -5pm, Monday - Friday, Easte rn Standard Tim e. At no time should [...]

  • Page 23

    20 10. QUALITY CERTIFICATE LAM10M IR serial n umber: _____________ ____________ _______________ ________ complies with all technical sp ecifications and has passe d the quality inspectio n. Date of production : ____________ _______________ ______ Quality Inspector : ___________________ _______________ Quality Assurance Seal[...]

  • Page 24

    NEWCON OPTIK ™ 2011 R1 – 2.11[...]