Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES should contain:
- informations concerning technical data of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES
- name of the manufacturer and a year of construction of the Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES item
- rules of operation, control and maintenance of the Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Monessen Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Monessen Hearth B-Vent Specialty Gas Fireplace System DESIGNER SERIES item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DESIGNER SERIES 624BVSTNV/624BVSTNE, 624BVPFNV/624BVPFNE 624BVCLNV/624BVCLNE, 624BVCRNV/624BVCRNE, 624BVBYNV/624BVBYNE B-V ENT S PECIAL TY G AS F IREPLACE S YSTEM I NST ALLA TION , O PERA TION AND M AINTENANCE M ANUAL D O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE . WHA T TO DO IF[...]

  • Page 2

    "W ARNING : I F NOT INST ALLED , OPERA TED AND MAINT AINED IN ACCORDANCE WITH THE MANUF A TURER ’ S INSTRUCTIONS , THIS PRODUCT COULD EXPOSE YOU TO SUBST ANCES IN FUEL OR FROM FUEL COMBUSTION WHICH CAN CAUSE DEA TH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE ST A TE OF C ALIFORNIA TO CAUSE CANCER , BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM [...]

  • Page 3

    T ABLE OF C ONTENTS 2 C22 C ONGRA TULA TIONS ! Y ou have chosen the finest decorative gas appliance available. Y our 6- IN -1 ™ Specialty Gas Fireplace has been designed for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your system. Model Dealer Serial No. Dealer Phone No. Gas T[...]

  • Page 4

    P ARTS D IAGRAM 3 MV MV PV PV N O C F F O 16 16 15 15 7 17 17 19 19 18 18 9 6 5 8 4 3 11 11 13 13 12 12 14 14 10 10 2 14 14 1 13 13 ON OFF PILOT TH TPTH TP 53D9019. Rev 3 11/07[...]

  • Page 5

    P ARTS L IST 4 All repair part orders should be placed through your local dealer . T o ensure prompt and accurate service, please provide the following information when placing a repair part order: Model num- ber of your Fireplace, Part Name, Part Number , and Quantity of parts needed. 6-IN-1 PART LIST 071589 071589 076673 076673 077620 077620 0709[...]

  • Page 6

    The table below is a list of components which may be safely used with this product. Configuration Kits 6BK Bay Kit 6CK Corner Kit (works for left or right side) 6IK Island Kit 6PNK Peninsula Kit 6SK See-Thru Kit Control Kits 6CN Control Kit Natural Gas Standing Pilot 6CLP Control Kit Propane/LP Gas Standing Pilot 6CEN Control Kit Natural Gas Electr[...]

  • Page 7

    F IREPLACE C ONFIGERA TION I NST ALLA TION 6 P ART 1 Remove front glass door by removing the cardboard fillers at the top and lifting up and away from the appliance. Install the handles onto the door using screws from the handle package. Keep front glass door of f of the appliance until installation of Configuration Kit (Part 2) and Control Kit (Pa[...]

  • Page 8

    23 1/8 FRAMING  FRAMING  DIM. FOR DIM. FOR SEE THRU SEE THRU 42 3/8 42 3/8 42 1/2 42 1/2 (FRAMING MIN.) (FRAMING MIN.) (ALL UNITS) (ALL UNITS) 1 1/2 MIN.  1/2 MIN.  CLEARANCE CLEARANCE 24 5/8 24 5/8 24 1/8 24 1/8 22 1/8 22 1/8 1 4 1/2 4 1/2 12 1/16 12 1/16 19 19 9 3/4 9 3/4 7 1/2 7 1/2 22 1/4 22 1/4 TOP VIEW TOP VIEW 37 1/4 37 [...]

  • Page 9

    To accommodate the various configurations, we have provided access openings in the bottom of the unit for gas line and wall switch wires. This may not be convenient for some installations, if so you may drill an access opening into the lower face of the unit (1" for gas line, 1/2" for the grommet). 1. Route the 3/8 inch N.P .T . black iro[...]

  • Page 10

    F IREPLACE I NST ALLA TION AND V ENTING 9 F IGURE 5F IGURE 6 APPROVED APPROVED COWL COWL MIN. MIN. 6 FT. 6 FT. SUPPORT SUPPORT 4 FT. 4 FT. MAX. MAX. APPROVED THIMBLE FOR APPROVED THIMBLE FOR 6" TYPE "B" GAS VENT 6" TYPE "B" GAS VENT CHIMNEY CHIMNEY GAS APPLIANCE GAS APPLIANCE WALL WALL FLOOR FLOOR THROUGH WALL THROUGH [...]

  • Page 11

    V ENTING R EQUIREMENTS 10 W ARNING : D O NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE . C ARBON DEPOSITS (S OOT ) AND CREOSOTE FROM SOLID FUELS CAN CLOG THE VENT FROM THE APPLIANCE CAUSING POISONOUS CARBON MONOXIDE TO BE RELEASED INT O THE ROOM IN WHICH THE APPLIANCE IS INST ALLED . All vented gas-f[...]

  • Page 12

    LOGS AND TWIGS. LOGS AND TWIGS. TOP VIEW OF TOP VIEW OF Curing Instructions Note: When lit for the first time the fireplace may emit a slight odor for several hours. This is due to the curing and "burn in" of external parts and lubricants used in the manufacturing process. This condition is temporary . Open doors and window to ventilate t[...]

  • Page 13

    Units with 6CEN Controls 1. Determine a convenient location within twenty (20) feet and cut a hole large enough to accommodate the wall switch yet be covered with a wall plate. It is not necessary to use a wall box, but one may be used. 2. Route the wire provided through the 1/2 inch black plastic grommet in the unit. 3. Route the wire into the wal[...]

  • Page 14

    Pilot Burner Adjustment 1. Adjust the pilot screw to provide a properly sized flame. 2. Do not adjust the pilot screw all the way out counterclockwise because it will leak gas. Flame Switch (For Units with 6CN and 6CLP Controls) Y our fireplace has been equipped with a thermocouple which senses the flame and shuts of the gas flow to the pilot and m[...]

  • Page 15

    Maintenance of the Appliance Air flowing through the appliance will cause dust and lint to collect on the grate, burner and logs. Exessive buildup of dust and lint can cause the pilot and burner to operate improperly and produce hazardous levels of carbon monoxide, a poisonous gas. The appliance may produce carbon (soot) during operation. This carb[...]

  • Page 16

    15 C OMBUSTION A IR P RECAUTIONS N OTE : The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use the model OAC4 combustion air kit. 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion ai[...]

  • Page 17

    C OMBUSTION A IR A SSEMBL Y 16 M ODEL AK4 C OMBUSTION A IR A SSEMBL Y 1. Remove the cover plate from the 4-inch outlet opening location on the left outside of the fireplace. DO NOT remove the cover if the outside air will not be connected. 2. Place the starting collar (4 inch) into the hole on the left side of the fireplace. Fasten it in place with[...]

  • Page 18

    OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS WARNING: FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING ON OFF TO TURN OFF GAS TO APPLIANCE TO TURN OFF GAS TO APPLIANCE KNOB KNOB INDICATOR INDICATOR POSITION POSITION GAS CONTROL GAS CONTROL THE FIRE DEPARTMENT. HAS BEEN UNDER WATER. OR EXPLOSION. CONTROL SYSTEM AND ANY GAS [...]

  • Page 19

    O PERA TING I NSTRUCTIONS 18 C. C. D. D. LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT. USE ONLY YOUR HAND TO PUSH IN OR TURN THE GAS USE ONLY YOUR HAND TO PUSH IN OR TURN THE GAS CONTROL KNOB. NEVER USE TOOLS. IF THE KNOB WILL C[...]

  • Page 20

    Correct installation and safe operation of this appliance require, but are not limited to the following: Do's: 1. Do use this appliance only on type of gas it is designed, certified and equipped. 2. Do install this appliance and all gas piping according to local codes, or in the absence of local codes, according to the current National Fuel Ga[...]

  • Page 21

    T ROUBLESHOOTING 20 While the manufacturer has made every reasonable effort to ensure that this appliance operates properly and satisfactorily , sometimes problems do arise. The following troubleshooting chart lists several problems with their probable cause and remedy . Any adjustments and/or replacements must be by a qualified person. Do not repl[...]

  • Page 22

    NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence. Installation of the fi replace or vented gas log in the State of Massachusetts requires the damper [...]

  • Page 23

    SPECIAL REQUIREMENTS CONTINUED 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFP A 720 and be ANSI/UL 2034 listed and IAS certi- fi ed. 3. SIGNAGE. A metal or plastic identi fi cation plate shall be permanently mounted to the exterior of the build- ing [...]

  • Page 24

    N OTES 21 53D9019. Rev 3 11/07[...]

  • Page 25

    N OTES 22 53D9019. Rev 3 11/07[...]

  • Page 26

    A TTENTION A PPLIANCE I NST ALLER P LEASE RETURN THESE O PERA TING AND I NST ALLA TION I NSTRUCTIONS TO THE A PPLIANCE FOR C ONSUMER U SE . 53D9019. Rev 3 11/07[...]