MGE UPS Systems 2200 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of MGE UPS Systems 2200, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of MGE UPS Systems 2200 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of MGE UPS Systems 2200. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of MGE UPS Systems 2200 should contain:
- informations concerning technical data of MGE UPS Systems 2200
- name of the manufacturer and a year of construction of the MGE UPS Systems 2200 item
- rules of operation, control and maintenance of the MGE UPS Systems 2200 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of MGE UPS Systems 2200 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of MGE UPS Systems 2200, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the MGE UPS Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of MGE UPS Systems 2200.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the MGE UPS Systems 2200 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation and user manual www .mgeups.com Pulsar Evolution 2200/3000/3000 XL[...]

  • Page 2

    Page 2 - 3400723100/AD SA VE THESE INSTRUCTIONS. This manual contains important instructions for 89347, 89348, and 89349 that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar Evolution range has been designed with the [...]

  • Page 3

    3400723100/AD - Page 3 Introduction CAUTION: Safety of persons ◗ The UPS has its own internal power source (the battery). Consequently , the power outlets may be energized even if the UPS is disconnected from the AC-power source. ◗ Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personne[...]

  • Page 4

    Page 4 - 3400723100/AD Foreword Using this document IMPORT ANT : Important instructions that must always be followed. NOTE: Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Information may be found in two ways, using: ◗ t[...]

  • Page 5

    3400723100/AD - Page 5 Contents 1. Presentation 1.1 Overall view .................................................................................................................................. 7 T ower position ..................................................................................................................................7 Rack[...]

  • Page 6

    Page 6 - 3400723100/AD Contents 6. Appendices 6.1 T echnical data ..............................................................................................................................24 Simplified diagram ..........................................................................................................................24 T echnical [...]

  • Page 7

    3400723100/AD - Page 7 1. Presentation 1.1 Overall view T ower position Rack position P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0 W H D Dimensions in inches (W x H x D) Evolution 2200 Evolution 3000 17.24 (19") x 3.56 (2U) x 25.2 Evolution 3000 XL Weight in lbs Evolution 2200 75 Evolution 3000 82 Evolution 3000 XL 46[...]

  • Page 8

    5-20P 72Vdc, 7Ah Pb 344-50 2 8 2 -00 TO B A TTERY C A B IN ET R S 2 3 2 S I TE W I R IN G 3 b attery c a b inets max F A UL T W A R NIN G O U T D ata l ine p r o te c ti o n IN H ert z 50 /6 0 Hz H ert z 50 /6 0 Hz A m p s 1 6 A M A X V ol t 1 2 0 V ~ 1 O V ol t 1 2 0 V ~ 1 O W / VA 1 540 W / 1 9 2 0 VA V ol t : 72Vdc 40 A A C O u t p u t A C I n p[...]

  • Page 9

    3400723100/AD - Page 9 1 2 % % 1.3 Control panel Bar graph indicating percent load at output. Group 1 programmable receptacles supplied with power . Illuminated ON/OFF button for the receptacles. Group 2 programmable receptacles supplied with power . Operation on battery power . 15 16 17 20 19 23 22 18 21 1. Presentation UPS fault. Battery fault. O[...]

  • Page 10

    P U L S A R Evolution 3 0 0 0 Page 10 - 3400723100/AD 2. Installation 2.1 Unpacking and parts check RS232 communications cable for Windows Operating Systems. For UNIX/Linux Operating Systems, please order , for free, the following part number: 66090 USB communications cable. T elescopic rails for mounting in 19" bay with mounting hardware. T w[...]

  • Page 11

    3400723100/AD - Page 11 2. Installation 2.2 Upright installation (tower position) Connect the two supports for the upright position. P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0[...]

  • Page 12

    P U L S A R Evolution 3 0 0 0[...]

  • Page 13

    3400723100/AD - Page 13 H ert z 50 /6 0 Hz H ert z 50 /6 0 Hz A m p s 1 6 A M A X V ol t 1 2 0 V ~ 1 O V ol t 1 2 0 V ~ 1 O W / VA 1 540 W / 1 9 2 0 VA V ol t : 72Vdc 40 A A C O u t p u t A C I n p u t U . S . P A T . N o . 6 , 0 9 4 , 3 6 3 B A TTERY C O NN E C TOR U . P . S . R 34 Z 5 A C I n p u t P r o g ramma b l e 2 P r o g ramma b l e 1 A C [...]

  • Page 14

    Only for 3000 72Vdc, 9Ah Pb 344-50297-00 TO BATTERY RS232 CABINET IN SITE WIRING FAULT max for 3000XL max for 3000 12 battery cabinets WARNING 3 battery cabinets OUT Data line protection Volt: 72Vdc 40A BATTERY CONNECTOR U.S. PAT. No. 6,094,363 Page 14 - 3400723100/AD Only for 3000 72Vdc, 9Ah Pb 344-50297-00 TO BATTERY RS232 CABINET IN SITE WIRING [...]

  • Page 15

    3400723100/AD - Page 15 2. Installation 2.7 Installation of the communications-card option 1 - Remove the slot cover 5 secured by two screws. 2 - Insert the card in the slot. 3 - Secure the cover with the two screws. It is not necessary to shut down the UPS to install the communications card. Slot for the communications-card option. 5 Only for 3000[...]

  • Page 16

    Page 16 - 3400723100/AD 1 2 % % 3. Operation 3.1 Start-up 15 16 17 Press the ON / OFF button 15 . The buzzer beeps and all the LEDs come ON. The buzzer beeps twice during the self-test, then button 15 remains ON, indicating that the receptacles are supplied with power . - AC power is present : Only button 15 is ON. The protected equip- ment is supp[...]

  • Page 17

    3400723100/AD - Page 17 1 2 % % 1 2 % % 3. Operation 3.3 Operation on battery power (following failur e of AC-input power) T ransfer to battery power The AC-input power is out of tolerances, LED 16 goes ON. During operation on battery power , the buzzer beeps every ten seconds. The equipment connected to the UPS is supplied by the battery . Thresho[...]

  • Page 18

    Page 18 - 3400723100/AD 3. Operation 3.4 Personalization (optional) Function Configurable function Automatic restart Cold start Forced reboot Energy saving UPS ON / OFF via software Default setting Enabled Enabled Enabled Disabled Enabled Personalization parameters can be set and modified using the UPS Driver software installed on a computer that i[...]

  • Page 19

    3400723100/AD - Page 19 3. Operation Configurable function Output voltage on battery power Upper threshold for transfer to battery power Fader-mode cut-in threshold Booster-mode cut-in threshold Lower threshold for transfer to battery power Maximum input-voltage range Default setting 120 V 151 V 132 V 102 V 89 V Disabled Options 100 V - 127 V 141 V[...]

  • Page 20

    Page 20 - 3400723100/AD T roubleshooting requiring MGE UPS SYSTEMS after-sales support 4. Maintenance 4.1 T rouble-shooting Indication LED 17 goes ON and the buzzer sounds continuously . Signification UPS electronics have detected a UPS fault. ◗ The connected equipment is no longer supplied. The equipment connected to the UPS is no longer protect[...]

  • Page 21

    3400723100/AD - Page 21[...]

  • Page 22

    Page 22 - 3400723100/AD I H F G 4. Maintenance Installation of the new battery module Carry out the above operation in reverse order . ◗ CAUTION: risk of electric arc when connecting the battery . ◗ T o maintain an identical level of performance and safety , use a battery module identical to that previously mounted in the UPS. ◗ Press the two[...]

  • Page 23

    3400723100/AD - Page 23 5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (c[...]

  • Page 24

    Page 24 - 3400723100/AD 6. Appendices 6.1 T echnical data Simplified diagram Input Output Battery Charger Inverter Booster / fader transformer Filter[...]

  • Page 25

    3400723100/AD - Page 25 6. Appendices T echnical characteristics Output rating AC-input power ◗ V oltage ◗ Frequency Output power (operation on battery power) ◗ V oltage ◗ Frequency Battery Environment ◗ Noise level (operation on AC-input power) ◗ Operating temperature ◗ Relative humidity Pulsar Evolution 2200 1920 V A / 1540 W (1) 6 [...]

  • Page 26

    Page 26 - 3400723100/AD 6. Appendices Examples of battery backup times Pulsar Evolution 2200 Pulsar Evolution 3000 Pulsar Evolution 3000 XL + 3 EXB 1 data server + 1 hard disk 2 distributed servers + 1 hub 8 rack-mounted servers 1 data server + 1 hard disk 4 distributed servers + 1 hub + 1 router 12 rack-mounted servers 1 telecom device 1 set of te[...]

  • Page 27

    3400723100/AD - Page 27 6. Appendices 6.2 Glossary Backup time T ime that the connected equipment can operate on battery power if AC-input power fails. Bar graph Device on the front panel indicating the percent remaining backup time or the percent load. Battery module (additional) Additional battery modules connected in parallel to increase the UPS[...]

  • Page 28

    Page 28 - 3400723100/AD 6. Appendices 6.3 Index A Automatic start ................................................................18 B Bar graph ..........................................................................9 Battery Additional modules ....................................................8 Backup time ....................................[...]

  • Page 29

    [...]

  • Page 30

    [...]

  • Page 31

    [...]

  • Page 32

    1660 Scenic Avenue Costa Mesa, CA 92626 USA www .mgeups.com[...]