Liebert Integrated Secured Protection manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Liebert Integrated Secured Protection, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Liebert Integrated Secured Protection one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Liebert Integrated Secured Protection. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Liebert Integrated Secured Protection should contain:
- informations concerning technical data of Liebert Integrated Secured Protection
- name of the manufacturer and a year of construction of the Liebert Integrated Secured Protection item
- rules of operation, control and maintenance of the Liebert Integrated Secured Protection item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Liebert Integrated Secured Protection alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Liebert Integrated Secured Protection, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Liebert service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Liebert Integrated Secured Protection.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Liebert Integrated Secured Protection item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    U SER M ANUAL English Integrated Secured Protection for Network Equipment Little Glass House[...]

  • Page 2

    2 SAFETY INSTRUCTIONS ................................................................................................................................... 3 GLOSSARY OF SYMBOLS ................................................................................................................................. 3 INTRODUCTION .............................[...]

  • Page 3

    3 SAVE THESE IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself. Opening or removing covers will risk exposure to dangerous voltages. Refer all servicing to qualified service personnel. 1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. Read all safety and operating instructions befor[...]

  • Page 4

    4 INTRODUCTION Your Liebert Little Glass House™ (LGH) will provide a secure controlled environment in a single factory assembled enclosure. The integrated/matched models are designed to control the environment and provide smooth reliable power so that your sensitive computer and network equipment will provide the reliable performance you depend u[...]

  • Page 5

    5 UPS SUPPORT The integrated/matched models include an uninterruptible power supply (UPS) module to provide surge suppression, regulated voltage and frequency, and battery backed operating time. This will allow you to perform a controlled computer shutdown in the event of a utility/mains power failure. The UPS supplied is a rackmount model factory [...]

  • Page 6

    6 ALCOVE INSTALLATION ECM ECM/UAS FAC Rear 12" 12" 12" Top 12" 12" 12" Sides 0" 0" 0" Bottom Non-Restricted The unit can be rolled forward on casters for easy access to Liebert and customer wiring at the rear of the unit. To open the front door, clearance required depends on the size of your unit. No sid[...]

  • Page 7

    7 bottom up, starting with the heavier units. Leave available space (if any) at the top of the enclosure. CAUTION: To avoid tipping the unit when it is being moved, push slowly on the lower part of the enclosure. After customer equipment is installed, the Little Glass House may have a high center of gravity. The LGH can support an electrical load b[...]

  • Page 8

    8 OPER ATION ENVIRONMENTAL CONTROL MODULE (ECM) & UNINTERRUPTIBLE AIR SUPPLY™ (UAS) For integrated/matched models, the Environmental Control Module is normally sized to match the capacity of the UPS module and heat transmitted into the Little Glass House™. The module is located at the bottom of the enclosure. Internal air is conditioned and[...]

  • Page 9

    9 An optional UPS status communication cable is available that allows transmission of information between the UPS and the SiteNet Integrator. This cable will plug into the 25 pin D Type connector on the rear of the UPS marked DB- 25P. The opposite end of the cable in plugged into the 9 pin D Type receptacle on the rear of the SiteNet Integrator mar[...]

  • Page 10

    10 MAINTENANCE CAUTION: To avoid tipping the unit when it is being moved, push slowly on the lower part of the enclosure. After customer equipment is installed, the Little Glass House™ may have a high center of gravIty. FILTER CLEANING NOTE: Inspect the air filter periodically to determine the necessary cleaning interval based on conditions at yo[...]

  • Page 11

    11 TABLES FORCED AIR COOLING (FAC) PERFORMANCE DATA (WITH 30PPI FILTER) AIRFLOW (w/Filter) SOUND LEVEL INPUT POWER (1PH) FLA / WSA / OPD MODEL # # FANS HIGH SPEED LOW SPEED HIGH SPEED LOW SPEED 120V/60Hz 220V/50Hz FAC-190 1 190 CMF 112 CMH 90 CMF 53 CMH 61 dBa 47 dBa 0.5/15/15 0.5/15/15 FAC-360 2 360 CMF 212 CMH 175 CMF 103 CMH 59 dBa 49 dBa 1.0/15[...]

  • Page 12

    12 Electrical Service / Connection The 60 Hz LGH is provided with a single NEMA plug and cord input power connection (except for ECM- 80 systems). 60 Hz Systems with UPS - Service Connection If a UPS is supplied, the system power rating and plug connection are fixed. FIXED SERVICE CONNECTION (AMPS) UPS-GXT (VA) Cooling System 1000 1500 2000 FAC-190[...]

  • Page 13

    13 DRAWINGS[...]

  • Page 14

    14[...]

  • Page 15

    15[...]

  • Page 16

    16[...]

  • Page 17

    17[...]

  • Page 18

    18[...]

  • Page 19

    19[...]

  • Page 20

    20[...]

  • Page 21

    21 0 1 0 2 0 3 0 4 0 20 0 40 0 60 0 80 0 100 0 120 0 140 0 INTERNAL LOAD PER CABINE T , WATT S MINIMUM SPEED SET AT 2000 RPM LGH RD/HD FORCED AIR CABINET TEM P . RIS E AT STANDARD AIR CONDITION S TEMP. RISE PER CABINET, DEG. F FAC-360(2 FAN) HIGH SPEE D FAC-190(1 FAN) HIGH SPEE D FAC-360(2 FAN) LOW SPEED FAC-190(1 FAN) LOW SPEED[...]

  • Page 22

    22 INTEGRATOR POWER, UPS, & TERMINAL CONNECTIONS[...]

  • Page 23

    23 TROUBLESHOOTING PROBLEM CAUSE SOLUTION No Power 60 HZ: Verify F2 fuse not blown by checking on/off switch. If not lit, fuse is blown 50Hz: Verify breaker has not tripped. Filter Clogged Clean, or replace filter Refrigerant loss Verify leak. If refrigerant system needs repaired, replace ECM. Hot Gas Bypass Valve set incorrectly Set valve correctl[...]

  • Page 24

    24 Limited Warranty (for U.S. Sales and Installations) We are pleased that you have purchased the Little Glass House™ product to enhance the environment and the reliability of the available AC power for your sensitive electronic equipment. Liebert Corporation warrants to the original user all parts that make up the Little Glass House for a period[...]

  • Page 25

    25 1050 Dearborn Drive  Columbus, OH 43229  614-888-0246 Technical Support U.S.A. 1-800-222-5877 Outside the U.S.A. 614-841-6755 U.K. +44 (0) 1793 553355 France +33 (0) 1 43 60 01 77 Germany +49 89 99 19 220 Italy +39 2 98250 1 Netherlands +31 (0) 475 503333 E-mail upstech@liebert.com Web site http://www.liebert.com Worldwide FAX tech support[...]