Lennox Hearth 038M manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth 038M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth 038M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth 038M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth 038M should contain:
- informations concerning technical data of Lennox Hearth 038M
- name of the manufacturer and a year of construction of the Lennox Hearth 038M item
- rules of operation, control and maintenance of the Lennox Hearth 038M item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth 038M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth 038M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth 038M.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth 038M item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EP A Wood-Burning Fireplace P/N 850,038M REV . B 02/2007 MONTEST MODEL MONTECITO EST A TE™ This installation manual will enable you to obtain a safe, efficient and de - pendable installation of your fireplace system. Please read and understan d these instructions before beginning your installation. Do not alter or modify the fireplace or its c[...]

  • Page 2

    W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flamma[...]

  • Page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Mo nte cit o E sta te ......... Page 3 Fuel .............................................[...]

  • Page 4

    The combustion air control should be opened before opening the doors to minimize the possi- bility of back draft coming into the room ( Figure 1-A ) More details are available in Refueling For Best Performance on Page 5 . Time Delayed Air Boost System The time delayed air-boost system register is located underneath the door handles. Placed in the f[...]

  • Page 5

    The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar - ranging the fuel so that air can get underneath will help the fire to get started easily . The unit should be operated with the air control fully open long enough to get the cord wood well ignited. REFUELIN[...]

  • Page 6

    Figure 5 IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fire- place as this will cause the fireplace to overheat. B. Never use gasoline, kerosene, charcoal lighter fluid or similar liquids to start or rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at all times. C. Do not burn coal. The sulp[...]

  • Page 7

    DOOR INST ALLA TION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door , to the female part, which is on the fireplace. T o remove the doors, simply pull them up from the hinges. The door adjustment has been set at the factor [...]

  • Page 8

    FIREPLACE INST ALLA TION Locating The Montecito Estate™ The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the locatio[...]

  • Page 9

    Figure 11 Insulated Chase Construction 7 Ft. Min. Attic Radiation Shield Ro of Su pp or t Storm Collar Flashing Dr yw al l o r An y Ri g id Ma te ri a l 2” x 4” 1/2” Plywood 6’ 8” Min. Firestop * Floor Ceiling Wall * Floor Ceiling Wall Fireplace Insulate Joists Same As Ceiling Draft Stops Firestop CTDT T ermination Note: Non- Combustible [...]

  • Page 10

    1. Combusti ble material must be insta lled flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 14 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 13 ) . MANTEL & F ACING The mante[...]

  • Page 11

    Figure 17 13” x 13” 10’ Max. 10’ Max. Rain Cap Flashing Collar Flashing Roof Support Attic Radiation Shield No n- Com bu st ibl e Fl am epr oo f Fa ci ng 56” Min. 68” Min. Figure 18 The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insu[...]

  • Page 12

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace: - Outside air kit (includes 40 inch flex that goes up to ten (10) feet long) - 4” Adaptor for fireplace connection Outside Air Installation The outside air assembly may be i[...]

  • Page 13

    8. A rain cap must be installed on top of the chimney . Failure to install a rain cap may cause corrosion problems. 9. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fill this 2” space with insulation or a[...]

  • Page 14

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22 ). Use a plumb bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 15 ) for the roof holes. Fro m belo w , ins tall a firest op in e[...]

  • Page 15

    Roof Down Slope Hole Size D E GR E E O F SL O P E S e cu r e T e mp ™ S 21 0 0 + N o va T e m p™ H T 6 0 0 0 + S e cu r e T e mp G X A C BI R o of P i t c h 7 ” 7 ” 0 * 1 5 ” ( 3 8 0 m m) 1 5 ” ( 3 8 0 m m) 2 / 12 1 5 -3 / 8 ” ( 3 90 m m ) 1 5 -3 / 8 ” ( 3 90 m m ) 4 / 12 1 6 -1 / 8 ” ( 4 10 m m ) 1 6 -1 / 8 ” ( 4 10 m m ) 6 / 1[...]

  • Page 16

    OFFSET CHIMNEY INST ALLA TION The minimum chimney height when using elbows is: C h i m n ey Elbow Offset & Height T wo Lengths Between Elbows 8” 12” 18” 24” 36” 8” & 36” 1 2” & 36 ” 1 8” & 36 ” 2 4 ” & 3 6” 36” & 36” GX S2 10 0+ HT 60 00 + 7” 15º A 3” (7 6 m m) 4- 1/4 ” (1 08 mm ) 5- 3/4 [...]

  • Page 17

    Figure 28 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 29 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETR[...]

  • Page 18

    ANGLED WALL RADIA TION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º C), [...]

  • Page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corre[...]

  • Page 20

    CHIMNEY - P ARTS AND COMPONENTS LISTS Secure T emp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Galvanized (7” ID & 11” OD) U.S.A. ONL Y Description Cat./Part No. Lengths & Misc. Chimney Components Length 8”, 7GXL8 7GXL8 Length 12”, 7GXL12 7GXL12 Length 18”, 7GXL18 7GXL18 Length 24”, 7GXL24 7GXL24[...]

  • Page 21

    ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Ch im ne y i s NO T r ec om me n de d a t el ev at i on s a bo ve 4 ,0 0 0 fe e t or i n c ol d c li ma te s ( cl im at es wh er e te m pe ra tu re s w il l fa l l be l ow 3 2° F / 0° C ). Description Cat./Part No. One of the following adaptors is required if installing an AC chimney syst[...]

  • Page 22

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fireplace front): 24” (457 mm) measured from the fireplace side. • Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace • Fireplace enclosure: Bottom: 0” Side: 0” Back: 0” • T op: Do not fill th[...]

  • Page 23

    NOTES 23[...]

  • Page 24

    Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS P/N 850,038M REV . B 02/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. LHP 1110 West T aft Avenu[...]