Lennox Hearth Brentwood SP manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth Brentwood SP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth Brentwood SP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth Brentwood SP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth Brentwood SP should contain:
- informations concerning technical data of Lennox Hearth Brentwood SP
- name of the manufacturer and a year of construction of the Lennox Hearth Brentwood SP item
- rules of operation, control and maintenance of the Lennox Hearth Brentwood SP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth Brentwood SP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth Brentwood SP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth Brentwood SP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth Brentwood SP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EP A W ood -Bu rni ng Fir epl ace s P/N 8 50, 039 M REV . G 1 1/2 008 BRENTWOOD SP MODEL BRENTWOOD™ This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fireplace or [...]

  • Page 2

    W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. IMPORT ANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERST AND THESE SAFETY R U L E S B E F O R E Y O U R F I R S T F I R E . IMPOR T ANT Wh en b urn in g wo od , us e SO LI D NA TU RAL DR Y WE LL -SE AS ONE[...]

  • Page 3

    T ABLE OF CONTENTS Safety Rules and Specifications for Mobile or Manufactured Home Installation ......................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Fireplace .................... Page 3[...]

  • Page 4

    Building a Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindling on top of the paper , criss-crossing the kindling so that there are air spaces in be- tween. Keep the fuel far back enough so that air can get underneath. Open the air controls fully[...]

  • Page 5

    B. Blowers operating (e.g.: range hood) These blowers draw air out of the house and may actually cause a negative pressure in the house. T urn off all blowers and open a nearby window to determine if this is the cause of the problem. C. Wet wood W et or tarred wood will smoulder and smoke instead of burn properly . D. Dirty or blocked chimney Check[...]

  • Page 6

    REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractor y . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractor y . If large cracks develop, then the refractor y should be replaced. T o replace the ref[...]

  • Page 7

    GLASS CARE Glass Replacement The glass used for the Brentwood™ fireplace is a high temperature ceramic glass (1,400° F). If the glass breaks, it must be replaced with an identical ceramic glass. T empered glass or ordinary glass will not withstand the high temperatures of the Brentwood fireplace. Replacement glass should be purchased from a Le[...]

  • Page 8

    Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figure s 7a, 7b and 8 ): A. Frame the fireplace using 2” x 3” or heavier lumber . B. WARNING: Combustible materials cannot be used in the space directly above the fireplace, except for the[...]

  • Page 9

    C om b u s ti b l e ma t er i a ls c a n N O T be us e d i n t he s p ac e di re c tl y ab ov e t h e fi re p la c e . D o n ot fi l l t h e sp a ce a bo ve th e fir ep l ac e wi th an y m at e r i al ( Ex ce p t t h e wo o d f r am in g ) F 19 -3 /3 2” J 20-1/2” E 7’ Min. 2” x 3’ Min. D Fireplace Framing Header B A OUTSIDE CHASE G H C[...]

  • Page 10

    Facing 1. Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 10 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 11 ) . Mantel The mantel must be[...]

  • Page 11

    HOT AIR DUCTING INST ALLA TION The Brentwood™ fireplace is approved for use with a Gravity Kit. Gravity Kit The gravity kit is designed for double hot air out- lets and includes: (See Figures 12 and 13 ) - 2 telescopic lengths 8” I.D. - 2 90º elbows 8” I.D. - 2 hot air outlet kits (grill and frames) - 2 adaptors See Gravity Kit Accessories [...]

  • Page 12

    6- 1/2 ” Mi n. (t o c ei li ng) Figure 13 Figure 14 Flashing Collar Rain Cap Roof Support Attic Radiation Shield Radiation Shield (Firestop) Non-Combustible Facing Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel. Ou tle t Gri ll Ou tle t Gri ll WARNING: The outlet grills sh[...]

  • Page 13

    The duct system must be installed respecting the following: 1. Remo ve the plat es clo sing up the 8” dia. hol es on top of the fireplace. Then, cut the insula- tion in order to obtain two 8” dia. openings. Fix the adaptors on the fireplace openings by turning clockwise ( Figure 12 ) . 2. Maintain at least a 2” (50 mm) clearance between the[...]

  • Page 14

    6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3m) of it ( Figure 17 ) . 7. If the chimney extends higher than five (5) feet (1,500 mm) above its point of contact with the roof, it must be secured us[...]

  • Page 15

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 18 ). Use a plumb-bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 13 ) for the roof holes. 2. From below , install a firestop in ea[...]

  • Page 16

    Roof Down Slope Hole Size S LO P E A SH T / H T 6 1 03 + S -2 1 0 0 + / H T6 0 0 0 + A C R oo f P it c h 6 ” 6 ” 6 ” 0 * 1 2- 3 / 8 ” ( 3 1 4 m m ) 1 4- 1 / 8 ” ( 3 5 9 m m ) 1 5” ( 38 0 m m) 2 /1 2 1 2- 9 / 1 6” ( 3 19 m m ) 1 4- 3 / 8 ” ( 3 6 5 m m ) 1 5 3 / 8 ” ( 3 9 0 m m ) 4 /1 2 1 3” ( 3 30 m m ) 1 4 -7 / 8 ” ( 3 7 8 m m[...]

  • Page 17

    Ch imn ey 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8” 1 8 ” & 48 ” 2 4” & 4 8 ” 36” & 48” 48” & 48” Se cu re T emp AS HT No va T emp HT 61 03 + 15º A 3- 5/ 16 ” (8 4m m) 4- 5/ 16 ” (1 10 mm) 5- 7/ 8?[...]

  • Page 18

    ANGLED WALL RADIA TION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only ( RSMI45) In cold climate locations (climates where temperatures will fall below 32° F / 0° C), we recom[...]

  • Page 19

    CHIMNEY SUPPORT INST ALLA TION Universal Roof Support This support has three possible uses: 1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney . 2. It may be used on a floor , ceiling or roof above an offset to support the chimney above the offset. 3. It may be used on a floor , ceiling or roof as a supp[...]

  • Page 20

    Follow these steps: 1- Position the fireplace in its location. T emporarily install the ASHT elbow on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney . 2- In the middle of the oval, drill a hole in the masonr y chimney at 30º. 3- Increase the size of the hole until [...]

  • Page 21

    Installation Accessories Description Cat./Part No. (Required - Order Separately) Black Cast Iron Door for Brentwood ™, BWBK H0516 Gold Plated Cast Iron Door for Brentwood, BWG H0517 Brushed Nickel Cast Door for Brentwood, BWBN H4849 Outside Air Kit (Required - Included With Fireplace) Outside Air Coupler to connect outside air UZI to fireplace, [...]

  • Page 22

    (AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior AC Starter Adaptors One of the following adaptors is required if installing an AC chimney system * AC Ch im ne y is N OT r ec om me nd ed a t el ev at io ns ab ov e 4 ,0 00 fe et o r in co ld c li ma te s ( cl im at es w he re t [...]

  • Page 23

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: Side wall: 17” (324 mm) measured from the fireplace side. Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace. Fireplace enclosure: Bottom : 0” Side: 0” to spacer Back: 0” to spacer T op: Do not fill the space above[...]

  • Page 24

    Printed in Canada © 2006 Lennox Hearth Products P/N 850,039M REV . G 11/2008 24 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Installed ___________________________ Y our Dealer's Name _____________[...]