Lennox Hearth Products Ladera-BK manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Lennox Hearth Products Ladera-BK, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Lennox Hearth Products Ladera-BK one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Lennox Hearth Products Ladera-BK. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Lennox Hearth Products Ladera-BK should contain:
- informations concerning technical data of Lennox Hearth Products Ladera-BK
- name of the manufacturer and a year of construction of the Lennox Hearth Products Ladera-BK item
- rules of operation, control and maintenance of the Lennox Hearth Products Ladera-BK item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Lennox Hearth Products Ladera-BK alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Lennox Hearth Products Ladera-BK, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Lennox Hearth Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Lennox Hearth Products Ladera-BK.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Lennox Hearth Products Ladera-BK item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EP A Wood-Burning Fireplace P/ N 50 602 3- 03 RE V . A 1 1/ 200 8 Ladera-BK Ladera-BN MODELS Ladera™ INST ALLA TION AND OPERA TION INSTRUCTIONS SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the[...]

  • Page 2

    W ARNING B e c a re f ul a dd i ng w oo d fu e l t o th e fi r e o r h a n d l i n g fi r e p l a c e t o o l s s u c h a s s ho v el s , t on g s o r po ke r s. W ARNING The bottom refractory can be cra cked by excess ive abuse s uch as tossing heavy logs onto the grate or gouging with fireplace tools. Exercise caution when adding wood to your [...]

  • Page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Ladera Fireplace ......... Page 3 Fuel ..................................................[...]

  • Page 4

    Building a Fire (starting and maintaining a fire) Note: Leave 1/2 inch of ashes at the bottom of the firebox. T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindling on top of the paper , criss-crossing the kindling so that there are air spaces in be- tween. Keep the fuel far back enoug[...]

  • Page 5

    A. Negative pressure in the house As the fire burns, air goes up the chimney . This air must be replaced through leakage into the house or through the outside air duct (optional). When operating the Ladera™ fireplace, open a nearby window temporarily to check if there is adequate replacement air supply . B. Fans operating (e.g.: range hood) The[...]

  • Page 6

    REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory . If large cracks develop, then the refractor y should be repl aced. T o repla ce the ref[...]

  • Page 7

    If possible, you should choose a location where the chimney will pass throu gh the house without cutting floor or roof joists (see fireplace dimen- sions Page 9 ). Usually , no additional floor support is needed for the fireplace. The adequacy of the floor can be checked by first estimating the weight of the fireplace system. Weights are giv[...]

  • Page 8

    Figure 7B Hearth Extension Requirements 39” (990mm) Min. 18” Area where wood mantel can be installed Non-Combustible Material 45 Deg. 4” 32-3/4” 17” Min. Hearth Extension Optional Cast Facade installation In sta ll the Fa cad e per ins tru cti ons pr ovi ded in Fa cad e K it (or de red se par ate ly - see Pa ge 22 ). Framing, Facing And M[...]

  • Page 9

    FPO FRAMING DIMENSIONS A 35-7/8 911 mm B 37-5/8” 956 mm C 29-1/8” 740 mm D 12-1/2” 318 mm E 70” 1778 mm F 35” 889 mm G *22” 559 mm J 49-1/2” 1257 mm K 8” 203 mm Fireplace Framing Header B A Corner Installation * T otal depth is 22-1/2 inches (572mm) including the back spacer minus 1/2 inch (13mm) for drywall to be flush with the fa[...]

  • Page 10

    Figure 9 Insulated Chase Construction Floor Ceiling Wall • Must have the same firestopping resistance as adjacent wall. • Must have the same insulation as adjacent ceiling. • Follow local rules regarding framing construction. 7’ (2.1 m) Min. Note: Floor and wall below the attic must be insulated using the same insulation. Attic Radiation Sh[...]

  • Page 11

    Once the repair is done, it is mandator y to apply a new high temperature black cement (Mill-Pack, available from your retailer) sealing the access plate and all screw holes. Because the Ladera fireplace is an air tight fireplace, failure to do so will reduce fireplace efficiency . T ightly screw the access plate back on place and reinstall the[...]

  • Page 12

    Figure 16 Rain Cap Flashing Collar Flashing Firestop 68” Min. (1727mm) 39” Min. (990mm) No n- Com bu st ibl e Fa ci ng Roof Support Attic Radiation Shield The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insulation in order to obtain two 8” [...]

  • Page 13

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 13 Figure 17 Figure 18 Aluminum T ape Insulation Blower Tightening Collar Flex 5” Diameter Adaptor Insulated Flex Pipe OUTSIDE AIR KIT (fireplace and AC chimney) The outside air kit is optional on the Ladera™ fireplace, but mandatory on the AC chimney . It can be burned drawing air only fr[...]

  • Page 14

    Outside Air Installation The outside air assembly may be installed according to the following requirements: A) Duct length should be kept to a minimum. The maximum length of a 4” interior diameter (100 mm) insulated flexible duct is twenty (20) feet (6.1 m). (See note below). B) The air intake register must not be installed more than ten (10) fe[...]

  • Page 15

    CHIMNEY INST ALLA TION INSTRUCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 23 ). Use a plumb-bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 16 ) for the roof holes. 2. From below, install a firestop in each [...]

  • Page 16

    Roof Down Slope Hole Size S L O P E A S H T + / H T 6 1 0 3 + S - 2 1 00 + / H T 6 0 00 + A C R o o f P it c h 6 ” 6 ” 6 ” 0 * 1 2 - 3 /8 ” ( 3 1 4 m m) 1 4 - 1 /8 ” ( 3 5 9 m m) 1 5 ” ( 38 0 m m ) 2 / 1 2 1 2 - 9 /1 6” ( 3 1 9 mm ) 1 4 - 3 /8 ” ( 3 6 5 m m) 1 5 3 /8 ” ( 3 9 0 mm ) 4 / 1 2 1 3 ” (3 30 m m ) 1 4 - 7 / 8 ” ( 3 7[...]

  • Page 17

    Figure 28 Ch im ne y 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8” 1 8” & 4 8” 2 4” & 4 8” 36” & 48” 48” & 48” Se cur e T em p AS HT No va T em p HT 610 3+ 15º A 3- 5 /1 6” (8 4 mm ) 4- 5 /1 6” (1 1 0m[...]

  • Page 18

    Figure 29 OFFSET CHIMNEY INST ALLA TION Chimney AC Support ACRS Starter Section Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 30 Straps Straps OFFSET CHIMNEY INST ALLA TION WITH WALL PENETRA TION Note: In cold areas it is recommended to protect the chimney in a insulated chase. NOTE: DIAGRAM[...]

  • Page 19

    ANGLED WALL RADIA TION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only ( RSMI45) In cold climate locations (climates where temperatures will fall below 32° F / 0° C), we recom[...]

  • Page 20

    CHIMNEY SUPPORT INST ALLA TION Universal Roof Support This support has three possible uses: 1. For ASHT+ / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney . 2. It may be used on a floor , ceiling or roof above an offset to support the chimney above the offset. 3. It may be used on a floor , ceiling or roof as a sup[...]

  • Page 21

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corre[...]

  • Page 22

    CHIMNEY - P ARTS AND COMPONENTS LISTS Installation Accessories Description Cat./ Part No. Outside Air Kit Outside Air Coupler T o Connect Outside Air (UZI) T o Fire- place, UZIAD UZIAD Ou tsi de Air Du cti n g - i n cl u de s 4 ” ins ula ted fle x x 10 ’ l o ng , U Z I UZI Gravity Kit Complete double ducting system including: 2 elbows 90º, 2 [...]

  • Page 23

    CHIMNEY - P ARTS AND COMPONENTS LISTS (AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior * AC Ch im ne y i s NO T re c om m e nd e d at e le v at io ns a b ov e 4, 00 0 fe e t or in c ol d c li m a te s ( cl i m at e s wh er e te mp er at ur es w il l fa ll b el ow 3 2° F / 0 °[...]

  • Page 24

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation; Side wall: 17” (324 mm) measured from the fireplace side Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace Fireplace enclosure : Bottom: 0” Side: 0’’ to spacer Back: 0’ ’ to spacer T op: Do not fill the space [...]

  • Page 25

    NOTES 25 THIS PAGE LEFT BLANK INTENTIONALL Y[...]

  • Page 26

    Printed in Canada © 2008 Lennox Hearth Products P/N 506023-03 REV . A 11/2008 26 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Installed ___________________________ Y our Dealer's Name ____________[...]