Leica B523 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Leica B523, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Leica B523 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Leica B523. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Leica B523 should contain:
- informations concerning technical data of Leica B523
- name of the manufacturer and a year of construction of the Leica B523 item
- rules of operation, control and maintenance of the Leica B523 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Leica B523 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Leica B523, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Leica service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Leica B523.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Leica B523 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Leica DB LB Research mi croscope and Stu do Lite Imaging so ftware Roo m B523 User Guide Molecular I maging Unit University of Helsinki www .m iu.helsin ki.fi 9.4.2008[...]

  • Page 2

    1 GENERA L USER INFORMATION .............................................................................. 1 2 SETTINGS FOR TRAN SMITTED LIGHT M ICROSCOPY...................................... 1 2.1 Turning on the microscope .................................................................................................... 1 2.2 XY-stage..........[...]

  • Page 3

    1 1 General user information Leica DM LB research microscope is onl y for th e Molecular Canc er Biology (MCBP) and Genome-scale Biology (GSB ) r esearch p rograms internal us e. It i s a transmitted light microscope that cannot be used for fluorescence microscop y . Bright-field, polarization contrast, and low-quality d ark-field i llumination are[...]

  • Page 4

    2 movement in y -direction (back and forth), lower in x -direction (side to side). If you need to rotate the stage to get the image in any wanted angle, open the rotation lock by unscrewing it and th en rotating the stage by ha nd (circle in Figure 2). Re-screw the lock after use! Figure 2. Adjustment wheels for stag e control (arrows) and ro tatio[...]

  • Page 5

    3 Objective Numerical Aperture (NA) Color ring Coverg lass (c .g.) thickness Position for auxili ary condensor lens N Plan 2.5x 0.07 Brown Any/without c.g. off N Plan 5x 0.12 Red Any/without c.g . off N Plan 10x 0.25 Yellow Any/without c.g. on N Plan 20x 0.4 Green 0.17 mm on N Plan 40x 0.65 Blue 0.17 mm on C Plan 63x 0.75 Black 0.17 mm on Table 1. [...]

  • Page 6

    4 The fine focus has two modes: when the left focus wheel is pulled out, each l ine on the wheel equals 1 µ m of movement. When it is pushed in, each line equals 4 µ m of movement. Figure 5. Focusing wheels 2.6 Eye pieces (oculars) Adjust the folding bridge o f the ocul ars until you see, using bot h e y es, onl y one circular field of view throu[...]

  • Page 7

    5 Figure 7. Dual viewing a ttachment Figure 8. Power source for the light pointer There is a light poin ter i n the viewing att achment that uses an external power sourc e. Thus, y ou need to connect the transformer into a power outlet b efore using the pointer (Figure 8). After use, disconnect the transformer. Notice that y ou can us e the monitor[...]

  • Page 8

    6 Figure 9. Light pointer controls 2.8 Koehler illumination Koehler ill umination needs to be adjusted in the beginning of ever y imagi ng session for optimal illumination. Proceed as follows: Instruction View in eyepiece 1. Use 10x objective and front lens. Focus on the sample. 2. Close the luminous-field diaphragm by turning t he adjustment wheel[...]

  • Page 9

    7 Instruction View in eyepiece 4. Center the diaphragm i n the field of view by r otating the condenser a djusti ng screws. In other words, you adjust the illuminating path so that it is pr operly aligned along the optical axis of the microscope. 5. Open t he l uminous- field diaphragm by turning t he adjustment whee l counter- clockwise until the [...]

  • Page 10

    8 2.9 Polarization contr ast Figure 10 . Analyzer for polarization contra st imaging Figure 11 . Polarizer For polarization contrast microscop y , an an alyzer (a polarizi ng filter) is inserted in the light path b y pus hing it all the wa y in (Fi gure 10), and another polarizing filter (polarizer) is placed labeled side upwards i n a holder below[...]

  • Page 11

    9 • Grun : a green panchromatic filter that was used for contrast enchantment for B/W photography These filters were used for fil m photography and are not useful for digital photography. However, when usin g low intensit y light (yellowish), DLF-filter adjusts the light back to the direction of blue, making the image more pleasant to view. Figur[...]

  • Page 12

    10 3 Image acquisition 3.1 Accessing the com puter If the computer is turned off, push the power b utton to turn it on. Whe n the lo gin screen appe ars, lo g in using y our hyad lo gin a ccount. C heck that the domain is set to LTDK. 3.2 View Finder applic ation A 10-bit Ol y mpus DP50 color CC D camera is attached on the t op of the microscope. I[...]

  • Page 13

    11 simply m ultiplied values, thus the same effect can be added later on in image editing software. Therefore, changing the value from 100 is not recommended. 3.3.3 Exposure Mode In the Exposure Mode box , select either Automatic or Manual : • Automatic ( AE) : The software mea sures the optim al expos ure ti me automatically. Change Spot and Exp[...]

  • Page 14

    12 Figure 16 . Histogram level adj ustment. Red square: levels butt on 3.3.6 Focus tool Focusing tool assi sts you i n focusing. If the focusing toolbar is not visible, enable it in the Options menu. Once activated, two bars appear (Figure 17). The bl ue one shows the curre nt focus v alue, and the red one a history of the best level reached since [...]

  • Page 15

    13 15). Make sure the stage do es not move at all between the images or image qualit y decreases. 3.4 Capturing the im age Press the Camera button next to the Live button to take an image. After acquisition, the image will appear in Studio Lite. 3.5 Viewing images To zoom in or out, select the zoom tool in the toolbar at the right edge of the scree[...]

  • Page 16

    14 3.6.2 Scale bars The Studio L ite software does not provide means to insert scale bars. They can be added later on in an y im age editing software such as Adobe Photoshop. R eady -made scale bars for the full resolution images are avail able at http://www.miu.helsinki.fi/instruments/LeicaDMLB/scale_pictures.htm (in P hotoshop format). The page a[...]

  • Page 17

    15 • Cover the microscope with the red hood 6 T roubleshooting 6.1 There is no light • Microscope is not turned on (see Section 2.1) • Light intensity set too low (see 2.1 on page 1) • Do you see any light in t he lamp chamber? If not, the halogen bulb m ay n eed to be changed - contact MIU 6.2 Light is too dark Check: • whether the polar[...]

  • Page 18

    16 6.7 Computer login fa ils Check that: • domain is LTDK • use are usi ng y our h yad account user ID and p assword - the same ones you are using for accessing your university e-mail account[...]