A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of JBL MPC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of JBL MPC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of JBL MPC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of JBL MPC should contain:
- informations concerning technical data of JBL MPC
- name of the manufacturer and a year of construction of the JBL MPC item
- rules of operation, control and maintenance of the JBL MPC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of JBL MPC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of JBL MPC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the JBL service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of JBL MPC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the JBL MPC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    21 MPC Series Power Amplifiers Owner ’ s Manual TD-000074-00 TD-000074-00 R e v . C[...]

  • Page 2

    1 T able of Contents T able of Contents .............................................................................................................. ..................................................................... 1 W ar ning notices .............................................................................................................[...]

  • Page 3

    2 Rack Mounting Precautions T o a void dama ge to the amplifier mounting ears and/or rack rails , the amplifier must be supported at all four corners when used in portable racks . Consult JBL Ser vice Dept for av ailability of R ear Support Brac ke ts . Lifting Precautions In order to saf ely mov e or install the amplifier, it is recommended that t[...]

  • Page 4

    3 Description T he MPC Series from JBL is a line of professional pow er amplifiers specifically designed for contracting applica tions . There are six models , eac h with two independent channels . Eac h model in the MPC Series line is availa b le in a T v ersion for dri ving either 200V , 140V , 100V , 70V , 50V , or 25V constant v oltage[...]

  • Page 5

    4 1 22 5 12 12 33 4 4 5 12 2 4 12 12 CH1 CH2 CH1 CH2 BRIDGE MONO BRIDGE MONO LOW IMPEDANCE LOW IMPEDANCE DIR. OUTPUT DIR. OUTPUT ISOL.OUTPUT ISOL.OUTPUT AUDIO TRANSFORMER AUDIO TRANSFORMER 70V 70V 25V 25V 100V 100V 07 0 1 0 0 07 0 1 0 0 0 0 -dB -dB 10 10 88 66 44 22 24 24 18 18 14 14 STEREO 12 12 CH2 INPUT CH1 C H2 C H 1 PARALLEL BRIDGE LEVEL LEVEL[...]

  • Page 6

    5 b) Dept hThe amplifiers require a r ac k depth of 45.7 cm (18 in) to clear the rear support ears . T he r ear panel is 42.9 cm (16.9 in) behind the plane of the fr ont mounting rails , allo wing some room for r outing of wires . Stability , Reliability and Protection The MPC Series is engineered for stability and exceptional reliability , w[...]

  • Page 7

    6 Outputs Cover ed barrier strips located on the r ear panel allow safe , shockproof speaker ca b le connec- tions to the amplifier outputs . See the dia grams for details on connecting speaker s and/or distributed (25V , 70V , 100, 140V , and 200V) lines . Insulated connector s of the type sho wn are recommended. Alw a ys make sure the amplifier i[...]

  • Page 8

    7 Driving Distributed Lines Make sure the sum of the pow er settings of all the speaker s does not exceed the po wer rating of the amplifier . Be aware tha t the actual power dra w on some loudspeakers can v ary considerably from their tap labels . The tap labelings on some speaker s refers to their power dr a w from the distributed line, w hile on[...]

  • Page 9

    8 Loading an amp channel Be careful not to o v er load the c hannel when combining low- impedance and distributed loads on the same amplifier c hannel, because either load af fects the amount of p ow er a vaila ble for the other . T he next two par ag raphs explain how the y load the amplifier output. Inter nal output signal f l o w Each T - [...]

  • Page 10

    9 The tables below ar e general guidelines on which combinations ar e acce ptable. MPC200T Sum of Speaker T aps Connected to AUDIO TRANSFORMER Outputs 0 W 22 W* 44 W** 88 W*** 175 W**** Load connected to 2 Ω ✔ ✗✗✗✗ LOW IMPE D ANCE 4 Ω ✔✔✔✗ ✗ output 8 Ω ✔✔✔✔✗ 16 Ω ✔✔✔✔✗ 32 Ω ✔✔✔✔✗ MPC300T S[...]

  • Page 11

    10 Using Multiple Distributed Line V oltages The MPC amplifiers allo w you to connect distributed lines to an y of the 100V , 70V , and 25V outputs at the same time. F or example, a single c hannel could driv e both a 70V and a 25V line; such flexibility could sa ve y ou the e xpense of an additional amplifier . The total pow er of all the speakers[...]

  • Page 12

    11 Bridged Mono Input Connection The follo wing dia grams show input and output connections for bridged mono mode . Note that the MPC200 and 200T models use a different method for bridged mono than do the MPC300, 300T , 600 & 600T . MPC200 & 200T Bridged Mono Configuration 1) T o engag e the bridged mono mode, jumper the barrier strip in[...]

  • Page 13

    12 Low Impedance Bridged Mono Applications T he bridged mono mode produces higher output v oltages with the trade-off of requiring a higher impedance load and providing a slightly lo wer damping factor . Never - theless , it is an eff ectiv e way of pr oviding v er y high power le vels to loudspeak er s such as 4 Ω or 8 Ω subw oofers. Minimu[...]

  • Page 14

    13 Controls T he c hannel atten uator controls , labeled in dB of atten uation, are located on the r ear panel. T hey ha ve 11 detents and are adjustable from 0 dB (full gain) to ∞ (full attenuation). Displays T he LED displa ys on models MPC200 and 200T are dif f erent from those on models MPC300, 300T , 600, and 600T . Models MPC300, MPC300T , [...]

  • Page 15

    14 AC Power The MPC amplifiers are av ailable for 120 or 220240 V A C, 50 or 60 Hz operation. Eac h amplifier is factory configured for the line volta g e of the market into whic h it is sold. Operation Before fir st turning on the amplifier, tur n the gain controls of fi.e ., fully counterc lockwise until you confirm the amplifier is oper[...]

  • Page 16

    15 Shor t-Circuit Pr otection MPC amplifier s use the prov en Output A veraging short circuit protection system. The circuit per mits full output cur rent even into r esistiv e or r eactiv e 2 Ω load, but reduces the current saf ely by about 75% if the output is shor ted. T ransient Muting T ur n-on and turn-off m uting k eeps transients[...]

  • Page 17

    16 Specifications Direct Output Models Audio Transfo rmer AND Direct Outputs Electronics MPC200 MPC300 MPC600 MPC200T MPC300T MPC600T Direct P ow er Out 4 Ω bridge 1 kHz, 1% THD 1 700 W 900 W 1800 W 700 W 900 W 1800 W 8 Ω bridge 45 Hz20 kHz, 1% THD 450 W 600 W 1200 W 450 W 600 W 1200 W 2 Ω load/channel 2 , 1 kHz, 1% THD 1 350 W 450 W 900 W[...]

  • Page 18

    17 Power Consumption Some background on A C ratings is necessar y to fully understand po wer consumption specifications . Essentiall y , ther e are thr ee ratings of interest: (1) the legal operating current as measured by the Saf ety Ag encies , (2) the maxim um e xpected a verage current dra w under worst-case pr og ram material, and (3) the peak[...]

  • Page 19

    18 Heat Emission Any pow er that enters the amplifier thr ough the power cor d and does not exit through the speaker outputs turns into heat, which the amplifier m ust rid itself of by exhausting it to the outside . In indoor use this may pr esent a challenge to the building s air conditioning system. Use the table below to predict the hea t tha[...]

  • Page 20

    19 T roubleshooting PROBLEM: Channel will not come out of muting .  Reduce the gain to ∞ a tten uation. If this releases the muting , raise the gain bac k up slowly while you watc h the SIGN AL and CLIP indicators . The problem may be an abnormal signal (possibly with ex cessi ve ultrasonic ener g y , for example) that could otherwise dama g e[...]

  • Page 21

    20 For Further Assistance WITHIN THE UNITED ST ATES: General Infor mation or T echnical Assistance F or more inf or mation on JBL products , inc luding these power amplifier s , contact your nearest JBL Professional products dealer or the JBL factory at the address below . Repairs Please do not ship your amplifier to JBL or a JBL authorized repair [...]

  • Page 22

    22 JBL Professional 8500 Balboa Boulevard, P .O. Box 2200 Northridge, California 91329 U.S.A. A Harman International Company MPC MANUAL 6/98[...]