A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of IPSO T45, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of IPSO T45 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of IPSO T45. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of IPSO T45 should contain:
- informations concerning technical data of IPSO T45
- name of the manufacturer and a year of construction of the IPSO T45 item
- rules of operation, control and maintenance of the IPSO T45 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of IPSO T45 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of IPSO T45, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the IPSO service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of IPSO T45.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the IPSO T45 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    4-08-43R5 August 201 1 Refer to Installation ma nual for full instructions. T30 and T45 T umbler s START 25 C H IG H T EM P M ED T E M P L O W T E M P NO H E A T 1 2 3 S E L E C T T E M P I N S E R T C O I N P U S H S T A R T 1 2 3 S E L E C T T E M P I N S E R T C O I N P U S H S T A R T START 25 C H I G H T E M P M E D T E M P L OW T EM P NO H EA[...]

  • Page 2

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT © Published by pe rmission of the cop yright owner . All rights reserved. No part of the cont ents of this book may be reproduced or transmitted in any form or by any means without the expressed writte n consent of the publisher . 4-08-43 1 T able of Contents Tumblers – T30[...]

  • Page 3

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT 2 4-08-43 T umbler s – T30 and T45 Introduction Model Identification Includes models with the follow ing control suffixes: T477C S T A R T 2 5 C H I G H T E M P M E D T E M P L O W T E M P N O H E A T 1 2 3 S E L E C T T E M P I N S E R T C O I N P U S H S T A R T 1 2 3 S E [...]

  • Page 4

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 3 TMB1974N 1 Serial Plate 1 Conversion T able Multiply By T o Obtain Multiply By T o Obtain Btu 0.252 kCal Pounds/sq. inch 0.06895 Bars Btu 1055 Joules Pounds/sq. inch 0.070 kg/sq. cm Inch 25.4 Millimeters Pounds (lbs.) 0.454 Kilograms Inches [...]

  • Page 5

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4 4-08-43 S pecifications and Dimensions N/A = Not Applicable Specific ations T30 T45 Noise level meas ured during operation a t operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet ( 1.6 meters) f rom floo r . 66 dBA 67 dBA Net We[...]

  • Page 6

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 5 Cabinet Dimensions NOTE: T o meet ADA compliance, install a 4 inch (102 mm) riser on T30 models only . TMB2332N TMB2332N C E F H J B D G I A M o d e l s ABCD E T30 28 in. (71 1 mm) 49 in. (1245 mm) 48.25 in. (1226 mm) 1 1.4 in. (290 mm) 10.7[...]

  • Page 7

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 6 4-08-43 Exhaust Outlet Locations TMB1969N TMB1969N B C A Models Rear Exhaust Diamet er A B C T30 Elliptical Fits 8 in. (203 mm) 36.54 in. (928 mm) 4.25 in. (108 mm) 62.42 in. (1585 mm) T45 Elliptical Fits 10 in. (254 m m) 40.88 in. (1038 mm) 4.75 in[...]

  • Page 8

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 7 Gas Connection Locations TMB1970N 1 1/2 in. NPT TMB1970N A B C 1 Models Gas Connection AB C T30 Non-CE and Non-Australian 75.20 in. (1910 mm) 1.74 in. (44 mm) 36.84 in. (936 mm) CE and Australian 75.28 in. (1912 mm) 2.5 in. (64 mm) 30.60 in.[...]

  • Page 9

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 8 4-08-43 Electrical Connection Locations TMB1971N TMB1971N A B E D C GAS AND STEAM ELECTRIC Models Electric Service Gas and Ste am Models Electric Models ABCD E T30 59 in. (1498 mm) 1.75 in. (44 mm) 35.63 in. (905 mm) 73.21 in. (1859 mm) 2.28 in. (58[...]

  • Page 10

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 9 Steam Connection Locations NOTE: All connections use 3/4 inch NPT pipe. TMB1972N C D A B A B Models Inlet O utlet AC B D T30 (Upper) 73.93 in. (1877 mm) 6.29 in. (160 mm) 62.71 in. (1592 mm) 2.39 in. (61 mm) T30 (Lower) 36.35 in. (923 mm) 6.[...]

  • Page 11

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 10 4-08-43 Inst allation Pre-Inst allation Inspection Upon delivery , visually insp ect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have th e carrier n[...]

  • Page 12

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 11 Figure 1 TMB21 10N NOTE: Shaded areas indic ate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installation. 2 Allow 2 – 4 in. (51 – 102 mm) o pening at top of machine to aid in remova l or installatio[...]

  • Page 13

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 12 4-08-43 Exhaust Requirement s Layout Whenever possible, install tumblers along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Elbows and long vents tend to increase dryi ng time. Construction mus[...]

  • Page 14

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 13 IMPOR T ANT : For best performance provide an individual exhaust duct for each tumbler . Do not install a hot water heater in a room containing tumblers. It is better to have the water heater in a separate room with a separate air inlet. In[...]

  • Page 15

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 14 4-08-43 NOTE: Do not install wire mesh or scr een in exhaust duct opening to avoid lint build-up or impacting proper discharge of air fr om tumblers. NOTE: Where exhaust duct pier ces a combustible wall or ceiling, the opening must be sized per loc[...]

  • Page 16

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 15 The vent collector system must be designed so the static back pressure measured 12 inches (305 mm) from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation s ticker on the rear of tumbler . Static[...]

  • Page 17

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 16 4-08-43 Figure 4 TMB2019N 1 NOTE: Wher e the exhaust duct pierces a combustible wall or ce iling, the opening MUST be sized per local codes. 2 Outlet Duct Diameter 3 45° T y pical LK J I HG F E DC BA 3 1 2 ONE MANIFOLD ASSEMBLY Duct Stat io n T30 [...]

  • Page 18

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 17 Figure 5 TMB2018N 1 NOTE: Wher e the exhaust duct pierces a combustible wall or ce iling, the opening MUST be sized per local codes. 2 Outlet Duct Diameter 3 45° T y pical 1 2 3 LK J I L K J I CONTINUE TO A CONTINUE TO A TWO MANIFOLD ASSEM[...]

  • Page 19

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 18 4-08-43 Electrical Requirements for Gas and S team Models Refer to T able 4 and Ta b l e 5 . NOTE: Minimum wire sizes ar e obtained from Canadian Electrical Code for 75°C Conductors and are intended for use as a guideline only . Electrical connect[...]

  • Page 20

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 4-08-43 19 For T45 Gas Models (For T otal Machine): Serial Plate Vo l t a g e T erminal Block Connections Required Current (Amps) Recommended Fuse or Breaker Rating (Amps) Breaker Poles Recommended Minimum Conductor Size (A WG [mm 2 ]) 208–240V/60Hz[...]

  • Page 21

    © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT T umblers – T30 and T45 20 4-08-43 Electrical Requirement s for Electric Models Refer to T able 6 . NOTE: Minimum wire sizes ar e obtained from Canadian Electrical Code for 75°C Conductors and are intended for use as a guideline only . Electrical connections should be made [...]