Intel SC5300 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Intel SC5300, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Intel SC5300 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Intel SC5300. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Intel SC5300 should contain:
- informations concerning technical data of Intel SC5300
- name of the manufacturer and a year of construction of the Intel SC5300 item
- rules of operation, control and maintenance of the Intel SC5300 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Intel SC5300 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Intel SC5300, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Intel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Intel SC5300.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Intel SC5300 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Intel® Server Chassis SC5300, SC5300 LX and SC5300 BRP User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/Products Order Number: C51486-003[...]

  • Page 2

    ii Intel® Server Chassis SC5300 User Guide Disclaimer Information in this document is provided in connection with Intel ® products. No license, expres s or implied, by estoppel or otherwise, to any intellectual property rights i s granted by this document. Except a s provided in Intel’s Terms and Conditions of Sale for such products, Intel assu[...]

  • Page 3

    Preface Intel® Server Chassis SC5300 User Guide iii Preface About this Manual Thank you for purchasing and using the Intel ® Server Chassis SC5300. This manual is written for system technicians w ho are responsible for tr oubleshooting, upgrading, and repairing this server chassis. This document provides a brief overview of the features of the ch[...]

  • Page 4

    Preface iv Intel® Server Chassis SC5300 User Guide Additional Information and Software If you need more information about this product or inf ormation about the accessories that can be used with this server chassis, use the following resources: For in-depth technical information ab out this product, including BIOS settings and chipset information [...]

  • Page 5

    Preface Intel® Server Chassis SC5300 User Guide v Safety Informa tion WARNING Before working with your server product, whet her you are using this guide or any other resource as a reference, pay close attention to th e safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing pr[...]

  • Page 6

    Preface vi Intel® Server Chassis SC5300 User Guide strap attached to chassis ground  any unpainted metal surface  on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the [...]

  • Page 7

    Preface Intel® Server Chassis SC5300 User Guide vii strap attached to chassis ground of the system—any unpai nted metal surface—when handling components. 6. Do not operate the system wit h the chassis covers removed. After you have completed the six SAFETY steps above, you can remove the system cover s. To do this: 1. Unlock and remove the pad[...]

  • Page 8

    Preface viii Intel® Server Chassis SC5300 User Guide Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheits hinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel- Serverplatinen und -Servergehäusen unter http://support.intel.com/support/mothe rb[...]

  • Page 9

    Preface Intel® Server Chassis SC5300 User Guide ix wieder an. Der Mikroprozessor und der Kühl er sind möglicherweise erhitzt, wenn das System in Betrieb ist. Außerdem können einige Platinen un d Gehäuseteile scharfe Spitzen und Kante n aufweisen. Arbeiten an Platinen und Geh ä use so llten vorsichtig ausgeführt werden. Sie sollten Schutzhan[...]

  • Page 10

    Preface x Intel® Server Chassis SC5300 User Guide Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le site http://support.intel.com/support/moth erboards/server/sb/CS[...]

  • Page 11

    Preface Intel® Server Chassis SC5300 User Guide xi Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous reco mmandons l'usage de gants de protection. Danger d'explosion si la batter i[...]

  • Page 12

    Preface xii Intel® Server Chassis SC5300 User Guide 1. Apague todos los dispositivos per iféric os conectados al sistema. 2. Apague el sistema presionan do el interruptor encendido/ap aga do. 3. Desconecte todos los cables de alim entac ión CA del sistema o de las tomas de corriente alterna. 4. Identifique y desconecte todos los cabl es enc hufa[...]

  • Page 13

    Preface Intel® Server Chassis SC5300 User Guide xiii Rivolgersi ad un tecnico specializzato per la riparazione de i compo nenti dell'alimentazione di questo prodotto. È possibile che il pr odotto disponga di più fonti di alim entazione. Non modificare o utilizzare il cavo di alime n tazione in c.a. fornito dal produttore, se non corrisponde[...]

  • Page 14

    Preface xiv Intel® Server Chassis SC5300 User Guide usate, seguire le istruzioni del produttore. Il sistema è progettato per funzionare in un a mbient e di lavoro tipo. Scegliere un a postazione che sia: Pulita e libera da particell e in sospensione (a parte la norm a le polvere pres ente nell'ambiente). Ben ventilata e lontana da fonti di c[...]

  • Page 15

    Contents Intel® Server Chassis SC5300 User Guide xv Contents Warnings ......................................................................................................... v 1. Chassis Description ....................................................................................... 1 Kit Contents..............................................[...]

  • Page 16

    Contents xvi Intel® Server Chassis SC5300 User Guide Replacing a Fixed Fan (For Base and BRP Chassis Only)................................................... 41 Replacing a Hot Swap Fan ................................................................................................... 42 Replacing the Front Panel Board ............................[...]

  • Page 17

    Contents Intel® Server Chassis SC5300 User Guide xvii Figures Figure 1. Screw Description ......................................................................................................... 1 Figure 2. Intel® Server Chassis SC5300 Base Front View.......................................................... 2 Figure 3. Intel® Server Chassis SC[...]

  • Page 18

    Contents xviii Intel® Server Ch assis SC5300 User Guide Figure 49. Installing a Hot Swap Fan ......................................................................................... 4 2 Figure 50. Removing the Front Panel Board ............................................................................. 43 Figure 51. Installing the Front Panel B[...]

  • Page 19

    Chassis Description Intel® Server Chassis SC5300 User Guide 1 1. Chassis Description This document applies to the Intel ® Server Chassis SC5300 Base, Intel® Server Chassis SC5300 Base Redundant Power (BRP) and Intel® Server Chassis SC5300 LX. Kit Contents The chassis subassembly kit includes one power cord , and a box that includes four chassis[...]

  • Page 20

    Chassis Description 2 Intel® Server Chassis SC5300 User Guide Power Delivery One fixed 600-W power supply with an integrated cooling fan. Upgrada ble to 730-W redundant power supplies One redundant capab le 730-W power supply module with an integrated cooling fan. Optional second redundant power supply module is available. One redundant capab le 7[...]

  • Page 21

    Chassis Description Intel® Server Chassis SC5300 User Guide 3 Chassis Front View SC5300 LX with Hot Swap Components TP00557 A B L C D E F G H I J K A. Hot Swap Power Supply/Second Hot Swap Power Supply (a ccessory) B. PCI Add-in Card Panel C. Processor Air Duct D. PCI Air Duct E. Hot Swap Fans – Large (2) F. Hot Swap Fans – Small (2) G. Hard D[...]

  • Page 22

    Chassis Description 4 Intel® Server Chassis SC5300 User Guide Front Panel Controls and Indicators TP00534 A B C E F G H I J K D A. ID Toggle Switch B. Reset Button C. NIC1 Activity LED (green) D. Sleep Button 1 E. Power Button F. Hard Drive Activity LED (bi-color) G. Power/Sleep LED (green) H. NIC2 Activity LED (green) I. ID LED (blue) J. Status L[...]

  • Page 23

    Chassis Description Intel® Server Chassis SC5300 User Guide 5 Descriptions of the front panel LEDs are listed in the following table. Refer to your server documentation for functionality of buttons. Table 2. Front Panel LED Descriptions LED Name Color Condition Description Green ON Power on Green BLINK Standby/Sleep (S1) Power/Sleep LED OFF Off (a[...]

  • Page 24

    Chassis Description 6 Intel® Server Chassis SC5300 User Guide Base Chassis Rear View TP00526 A B C D E G F A. Fixed Power Supply B. I/O Ports C. PCI Add-in Card Slots D. PCI Card Latch E. Rear Serial B Connector (optiona l) F. ICMB or SCSI Knockout G. AC Power Connector Figure 5. Intel® Server Chassis SC5300 Base Chassis Rear View[...]

  • Page 25

    Chassis Description Intel® Server Chassis SC5300 User Guide 7 Base Redundant Power and SC5 300 LX Chassis Rear View TP00540 A B C D E G F A. Removable Power Supply B. I/O Ports C. PCI Add-in Card Slots D. PCI Card Latch E. Rear Serial B Connector (optiona l) F. ICMB or SCSI Knockout G. Power Supply Filler Panel Figure 6. Intel® Server Chassis SC5[...]

  • Page 26

    Chassis Description 8 Intel® Server Chassis SC5300 User Guide Chassis Side View TP00533 Figure 7. Intel® Server Chassis SC5300 Side View Peripherals 5.25-in Half-height Peripheral Bays Note : One multi-purpose 5.25-in drive carrier is included with the chassis. This drive carrier can hold either a floppy drive (by removing the knock-o ut) or a fi[...]

  • Page 27

    Chassis Description Intel® Server Chassis SC5300 User Guide 9 Accessories and Order Codes Spares and Accessories are detailed in the configuration guide fo r the server board. For a complete list of Spares and Accessories, re fer to the configuration guide stored on the Intel support site at: http://intel.com/support/motherboards/server/ Table 3. [...]

  • Page 28

    Setting Up the Chassis 10 Intel® Server Chassis SC5300 User Guide 2. Setting Up the Chassis This chapter describes how to set up your server chassis for the first time. Tools and Supplies Needed  Phillips (cross head) screwdriver (#2 bit)  Small flat-head screwdriver  Anti-static wrist strap (recommended) Installation Safety Instructions [...]

  • Page 29

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 11 Warnings and Cautions These warnings and cautions apply whenever you remove the access cover(s) to access components inside the server. Only a technically qualified person should integrate and configure the server. WARNINGS The power button on the front panel DOES NOT turn off the A[...]

  • Page 30

    Setting Up the Chassis 12 Intel® Server Chassis SC5300 User Guide Remove Primary Access Cover When facing the front of the chassis, the Primary Access cover is on the left-hand side for pedestal- mounted servers, and on top for rack-mounted servers. ✏ NOTE The front bezel also locks the primary access cover. Make sure the bezel lock is unlocked [...]

  • Page 31

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 13 Remove Bezel Assembly ✏ NOTE If the chassis is on its side, move the chassis to hang over the side of a table before proceeding. 1. Release the two plastic tabs (letter “A”) on the left side of the Bezel Asse mbly to disengage the tabs. 2. Rotate the Bezel Assemb ly (letter ?[...]

  • Page 32

    Setting Up the Chassis 14 Intel® Server Chassis SC5300 User Guide Remove Air Ducts 1. Press the latch (letter “A”) and remove th e PCI air duct (letter “B”) from the chassis. 2. Remove the processor air duct (letter “C”). TP00529 B C A Figure 10. Removing Air Ducts[...]

  • Page 33

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 15 Remove Hot Swap Fans ✏ NOTE This step only applies to the Server Ch assis SC5300LX and SC5300BRP configurations. The Server Chassis SC5300BASE confi guration ships with fixed fans. 1. Press latch (letter “A”) on fan and pull on handle to remove Hot Swap Fan from chassis. 2. Re[...]

  • Page 34

    Setting Up the Chassis 16 Intel® Server Chassis SC5300 User Guide Route Power and Data Cables to the Fixed Drives 1. Press on two plastic tabs (letter “A”) and rem ove PCI Add-in Card Reta iner and any full height PCI cards that may block access (this will a llow access to the cable routing slot). A A PCI Add-in Card Retainer TP00525 Figure 12[...]

  • Page 35

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 17 2. Route longest power cables to the 6-drive bay and shorter cables to the 4-drive bay and upper device bay. Power Cable Routing Guidelines: • P3, P4 and P5 power cables route to removable drives. • P6, P7, P8, P9, P10 and P11 power cables (standard SCSI/IDE); route as appropria[...]

  • Page 36

    Setting Up the Chassis 18 Intel® Server Chassis SC5300 User Guide 3. Route SCSI/SATA data cables through the ch assis openings located near the bottom of the drive cage. Connect data cables to the resp ective fixed drive and to the appropriate connector on the server board. TP00552 T o 4-Dr ive Cage T o 6-Dr ive Cage 4/6-Drive Ba y Cables Upper Ba[...]

  • Page 37

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 19 3. Attach floppy drive to floppy drive tray with screws, using holes marked “FDD.” 4. Attach black plastic bezel to front of floppy drive tray (letter “A”). Remove slides from hard drive position and attach slides to floppy drive tr ay by pressing the slides firmly into the [...]

  • Page 38

    Setting Up the Chassis 20 Intel® Server Chassis SC5300 User Guide Install DVD or CD-ROM Drive. 1. Remove a filler panel/slide a ssembly from the upper device bay. TP00535 Filler P anel A A Figure 17. Removing Slide/Filler Pa nel Assembly from Upper Device Bay 2. Attach slides to the DVD or CD-ROM d rive by pr essing the slides firmly into the side[...]

  • Page 39

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 21 Install Fixed Hard Drive(s) 1. Push the blue plastic release mechanism upwar d to release the Fixed drive cage (letter “A”). Pull out the drive cage so that it is partially e xposed (about 2 inches out) from th e drive bay slot in the chassis (letter “B”). Partially exposi n[...]

  • Page 40

    Setting Up the Chassis 22 Intel® Server Chassis SC5300 User Guide 3. Open the lower door. TP00920 Figure 21. Opening Lower Drive Cage Door 4. Remove a pair of device slides from the drive cage. TP00563 Figure 22. Remove Slides from Drive Cage Door[...]

  • Page 41

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 23 5. Attach the device slides to the hard drive. Th is is a tool-less operation. Insert tabs on device slides into mounting holes on hard drive and then press firmly to secure device slides to hard drive. Ensure that the metal tabs on the device s lides are facing the front of the har[...]

  • Page 42

    Setting Up the Chassis 24 Intel® Server Chassis SC5300 User Guide 8. Close the lower door of drive cage. TP00548 Figure 25. Closing Lower Door of Fixed Drive Cage 9. Close the upper door of drive cage. TP00550 Figure 26. Closing Upper D oor of Fixed Drive Cage 10. Tighten the thumb screw. Install power and data cables to connectors on hard drive(s[...]

  • Page 43

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 25 Install Hot Swap Drive(s) 1. Press in on the green latch (letter “A”) at th e end of the drive carrier to disengage it from the hot swap drive cage. Pull out on the black lever (letter “B”) to fully open the drive carrier. When the lever reaches a fully opened position, it w[...]

  • Page 44

    Setting Up the Chassis 26 Intel® Server Chassis SC5300 User Guide 5. With the black lever open, insert the drive carri er into the drive cage. Once inserted, rotate the black lever upwards to latch the drive carrier into position. TP00930 Figure 31. Inserting Drive Carrier into Drive Cag e Install Hot Swap Fans ✏ NOTE This step only applies to t[...]

  • Page 45

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 27 Install Server Board See your Intel® Server Board Quick Start User’s Guide for server board installation instructions and installation of the back panel I/O shield. Use the mounting screws, bumpe rs and standoffs (if necessary) that came with your chassi s to secure the server bo[...]

  • Page 46

    Setting Up the Chassis 28 Intel® Server Chassis SC5300 User Guide Connect Cables to Server Board 1. See your Intel® Server Board User Guide or Quick Start User’s Guide for cable connection locations. ✏ NOTE Use caution in routing cables to ensure that cables do not obstruct airflow from the fans. 2. If your server has a hot swap power supply,[...]

  • Page 47

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 29 Install Add-in Board(s) You may want to install an operating system before installing any add-in boards . CAUTIONS Do not overload the server board by installing add-in boards that dr aw excessive current. Add-in boards can be extremely sensitiv e to ESD and always require careful h[...]

  • Page 48

    Setting Up the Chassis 30 Intel® Server Chassis SC5300 User Guide 2. Open back panel PCI Add-In Card Retenti on Device (letter “A”) by pressing open from the inside of the chassis. Remove the PCI slot sh ield (letter “B”) by pushing shield out from the inside of the chassis. TP00542 C A B Figure 37. Preparing the Chassis for a PCI Add-in B[...]

  • Page 49

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 31 4. Hold PCI add-in board by its top edge or upper corners. Firmly press board into an expansion slot on the server board (letter “A”). Close back panel PCI Add-in Card Retention Device (letter “B”). TP00555 B A Figure 38. Installing an Add-in Board 5. Repeat Step 4 until all[...]

  • Page 50

    Setting Up the Chassis 32 Intel® Server Chassis SC5300 User Guide 6. Reinstall the PCI Add-in Card Retainer. TP00691 Figure 39. Replacing PCI Add-in Card Retainer 7. Attach cables if necessary.[...]

  • Page 51

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 33 Install Air Ducts 1. If your system has two processors, remove the inner plastic air baffle from the inside of the Processor Air Duct. ✏ NOTE This step only applies to systems with two processors. If your server board has only one processor installed, leave the inner air baffle in[...]

  • Page 52

    Setting Up the Chassis 34 Intel® Server Chassis SC5300 User Guide 3. Install Processor Air Duct into chassis (letter “A”). Install PCI Air Duct (letter “B”) and latch (letter “C”) into place. ✏ NOTE The Processor Air Duct interlocks with the PCI Air Duct in two places before latching into place. TP00562 B A C Figure 42. Installing Ai[...]

  • Page 53

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 35 Install an Additional Hot Swap Power Supply Module ✏ NOTE This step only applies to chassis with redundant power supply capability. Do not perform this step if your chassis has a fixed power supply. 1. Loosen screw (letter “A”) and remove power supply filler pane (letter “B?[...]

  • Page 54

    Setting Up the Chassis 36 Intel® Server Chassis SC5300 User Guide Install Bezel Assembly (Pedestal Only) ✏ NOTE This step applies to a pedestal configured chassis only. For instructions on installing a bezel in a rack configuration, refer to the Rack Conversion Kit Installation Guide: Intel® Server Chassis SC5300. TP00541 A B A D D C 40 ˚ Max [...]

  • Page 55

    Setting Up the Chassis Intel® Server Chassis SC5300 User Guide 37 Install Primary Access Cover 1. Slide Primary Access Cover on chassis. 2. Latch securely to the chassis. 3. If the chassis will be re-shipped, insert the shipping screw (label ‘A’). TP00915 A A Figure 46. Installing the Access Cover[...]

  • Page 56

    Setting Up the Chassis 38 Intel® Server Chassis SC5300 User Guide[...]

  • Page 57

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 39 3. Maintaining Y our Server This chapter describes how to replace components in your server after it has been set up. Tools and Supplies Needed  Phillips (cross head) screwdriver (#2 bit)  Antistatic wrist strap (recommended)  Needle-nosed pliers Safety: Before You Remove [...]

  • Page 58

    Maintaining Your Server 40 Intel® Server Chassis SC5300 User Guide CAUTIONS ESD can damage disk drives, boards, and other parts. Perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antista tic wrist strap attached to chassis ground  any unpainted metal surface [...]

  • Page 59

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 41 Replacing a Fixed Fan (For Base and BRP Chassis Only) 1. Remove Primary Access Cover (see “Remove Primary Acces s Cover” in Chapter 2 for step-by- step instructions). 2. Disconnect fan power cable from server board. 3. Remove the 92-mm (letter “A”) or 120-mm (letter “B”[...]

  • Page 60

    Maintaining Your Server 42 Intel® Server Chassis SC5300 User Guide Replacing a Hot Swap Fan 1. Remove Primary Access Cover (see “Remove Primary Access Cover” in Chapter 2 for step-by- step instructions). 2. Press latch (letter “A”) on fan and pull on handle to remove Hot Swap Fan from chassis. A TP00908 Figure 48. Removing a Hot Swap Fan 3[...]

  • Page 61

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 43 4. Replace Primary Access Cover (see “Ins tall Primar y Access Cover” in Chapter 2 for step-by-step instructions). Replacing the Front Panel Board 1. Remove the Primary Access Cover (see “Re m ove Primary Access Cover” in Chapter 2 for step-by-step instructions). 2. Remove [...]

  • Page 62

    Maintaining Your Server 44 Intel® Server Chassis SC5300 User Guide 4. Attach front panel cable (letter “A”) before installing the new Front Panel Board into the chassis to ensure the cable pins line up co rrectly. Place the new Front Panel Board in the chassis. Insert and tighten the three screws (l etter “B”) removed earlier. Connect the [...]

  • Page 63

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 45 4. Remove the eight screws holdi ng the Fixed Power Supply shield in place (letter “A”). Remove the two screws holding the Fixed Power Suppl y inside the power supply bay (letter “B”). Remove the Fixed Power Supply (letter “C”). A C B TP00694 Figure 52. Removing Fixed P[...]

  • Page 64

    Maintaining Your Server 46 Intel® Server Chassis SC5300 User Guide Replacing a Hot Swap Power Supply WARNINGS Hazardous conditions, power supply : Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servic ing should be done by technically qualified personnel. 1. Remove [...]

  • Page 65

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 47 Replacing a Power Distribution Board WARNINGS Hazardous conditions, power supply : Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servic ing should be done by technically qualified personnel. 1. Disc[...]

  • Page 66

    Maintaining Your Server 48 Intel® Server Chassis SC5300 User Guide 6. Remove screw (letter “A”) securing center di vider to power supply cage. Push center divider straight back (letter “B”) o release tabs from ch assis slots. Then, while holding the right edge of the center divider at a downward angle, dise ngage tabs from chassis wall by [...]

  • Page 67

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 49 7. Loosen thumb screw (letter “A”) securing Po wer Distribution Board to chassis. Lift Power Distribution Board off of standoffs (letter “B”) and then remove through back of power supply cage. You may have to feed the power cable s through the power supply cage while removi[...]

  • Page 68

    Maintaining Your Server 50 Intel® Server Chassis SC5300 User Guide 8. Insert new Power Distribution Board into power supply cage (letter “A”). Try to route the power cables to the appropriate area at the time of insertion (see Steps 9 and 10 below). Position the Power Distribution Board on the four standoffs inside the power supply cage. Push [...]

  • Page 69

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 51 11. Reinstall center divider and secure to chassis with one screw. Figure 59. Reinstalling Center Divider 12. Reinstall Hot Swap Power Supply(ies). Reinstall screw (letter “A”) if shipping chassis to another location. TP00544 A Figure 60. Reinstalling Hot Swap Power Supply 13. [...]

  • Page 70

    Maintaining Your Server 52 Intel® Server Chassis SC5300 User Guide Upgrading from a Fixed Power Supply to a Hot Swap Power Supply WARNINGS Hazardous conditions, power supply : Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servic ing should be done by technically qu[...]

  • Page 71

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 53 6. Remove the screw (letter “A”) securing the cen ter divider to the power supply cage. Push the center divider straight back (letter “B”) to release tabs from chassis slots. B A TP01998 Figure 62. Releasing Center Divider from Power Supply Cag e[...]

  • Page 72

    Maintaining Your Server 54 Intel® Server Chassis SC5300 User Guide 7. While holding the right edge of the center di vider at a downward angle (letter “A”), disengage the tabs from the chassis wall by rotating the cen ter divider out of the slots. Remove center divider from the power supply cage (letter “B”). TP01999 A B Figure 63. Removing[...]

  • Page 73

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 55 8. Insert the new Power Distribu tion Board into the power supply cage (letter “A”). Try to route the power cables to the appropriate area at the time of insertion (see Steps 9 and 10). Do not secure the Power Distribution Board yet. A TP01996 Note : Cables on back of Power Dis[...]

  • Page 74

    Maintaining Your Server 56 Intel® Server Chassis SC5300 User Guide 11. Reinstall the center divider into the middle pos ition (letters “A” and “B”) and secure to chassi s with one screw (letter “C”). Figure 65. Reinstalling Center Divider 12. Position the Power Distribution Board on the four standoffs inside t he power supply cage. Pus[...]

  • Page 75

    Maintaining Your Server Intel® Server Chassis SC5300 User Guide 57 13. Install the Hot Swap Power Supply. Install sc rew (letter “A”) if shipping chassis to another location. TP00544 A Figure 67. Reinstalling Hot Swap Power Supply 16. Reinstall the Air Ducts (see “Install Air Ducts” in Chapter 2 for step-by-step instructions). 17. Replace [...]

  • Page 76

    Maintaining Your Server 58 Intel® Server Chassis SC5300 User Guide[...]

  • Page 77

    Technical Reference Intel® Server Chassis SC5300 User Guide 59 4. T echnical Ref erence Power Supply Specifications 600-W Single Power Supply Input Voltages 600-W Power Supply  100-127 V ∼ at 50/60 Hz; 10 A max.  200-240 V ∼ at 50/60 Hz; 5 A max. 600-W Single Power Supply Output Voltages 600-W Power Supply The table below lists the total[...]

  • Page 78

    Technical Reference 60 Intel® Server Chassis SC5300 User Guide 730-W Single Power Supply Input Voltages 730-W Power Supply  100-127 V ∼ at 50/60 Hz; 10 A max.  200-240 V ∼ at 50/60 Hz; 5 A max. 730-W Single Power Supply Output Voltages 730-W Power Supply The table below lists the total wattage available from the power subsystem for each [...]

  • Page 79

    Technical Reference Intel® Server Chassis SC5300 User Guide 61 System Environmental Specifications Table 6. Environmental Specifications Temperature Non-operating Operating –40 ° to 70 °C. 5 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum of 10,000 ft. Humidity Non-operating 90% relative humidity (non-condensing) at 30 °C[...]

  • Page 80

    Equipment Log and Worksheets 62 Intel® Server Chassis SC5300 User Guide Equipment Log and W orksheets Equipment Log Use the blank equipment log provided here to reco rd information about your ser ver. You will need some of this information when you run the SSU. Item Manufacturer Name and Model Nu mber Serial Number Date Installed Chassis Server Bo[...]

  • Page 81

    Equipment Log and Worksheets Intel® Server Chassis SC5300 User Guide 63 Equipment Log (continued) Item Manufacturer Name and Model Nu mber Serial Number Date Installed Intel® Management Module Local Control Panel[...]

  • Page 82

    Equipment Log and Worksheets 64 Intel® Server Chassis SC5300 User Guide Current Usage Calculating Power Usage The total combined wattage for your configuration must be less than the wattage rating for your power supply. Use the two worksheets in this section to calculate the total used by your configuration. For current and voltage requirements of[...]

  • Page 83

    Equipment Log and Worksheets Intel® Server Chassis SC5300 User Guide 65 Worksheet, Total Combined Power Used by the Server 1. From the previous worksheet, ente r the total current for each column. 2. Multiply the voltage by the total current to get the total wattage for each voltage level. 3. Add the total wattage for each voltage level to arrive [...]

  • Page 84

    Regulatory and Compliance Information 66 Intel® Server Chassis SC5300 User Guide Regulator y and Compliance Inf ormation Product Regulatory Compliance Product Safety Compliance The Intel® Server Chassis SC5300 complies with the following safety requirements:  UL60950 – CSA 60950(USA / Canada)  EN60950 (Europe)  IEC60950 (International)[...]

  • Page 85

    Regulatory and Compliance Information Intel® Server Chassis SC5300 User Guide 67 Certifications / Registrations / Declarations  UL Certification (US/Canada)  CE Declaration of Conformity (CENELEC Europe)  FCC/ICES-003 Class A Attestation (USA/Canada)  VCCI Certification (Japan)  C-Tick Declaration of Conformity (Australia)  MED D[...]

  • Page 86

    Regulatory and Compliance Information 68 Intel® Server Chassis SC5300 User Guide GOST R Marking Russia RRL MIC Mark Korea China Compulsory Certification Mark China Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause h[...]

  • Page 87

    Regulatory and Compliance Information Intel® Server Chassis SC5300 User Guide 69 This equipment has been tested and found to comp ly with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These lim its are designed to provide reasonable protection against harmful interference in a residential insta llation. This equipm[...]

  • Page 88

    Regulatory and Compliance Information 70 Intel® Server Chassis SC5300 User Guide VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If th is is used near a radio or television receiver in a domestic env[...]

  • Page 89

    Regulatory and Compliance Information Intel® Server Chassis SC5300 User Guide 71 Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other component will void the UL listing[...]

  • Page 90

    Getting Help 72 Intel® Server Chassis SC5300 User Guide Getting Help World Wide Web http://support.intel.com/support/mot herboards/server/chassis/SC5300 Telephone All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card e x c h a n g e r a t e p l u s a p p l i c a b l e t a x e s . (Intel reserves the ri[...]

  • Page 91

    Getting Help Intel® Server Chassis SC5300 User Guide 73 In Latin America Brazil 001-916-377- 0180 Mexico contact AT&T USA by dialing 001-800-462- 4240; once connected, dial 8 00-8 43-4481 Colombia contact AT&T USA by dialing 01-800-911- 0010; once connected, dial 8 00-8 43-4481 Costa Rica contact AT&T U SA by dialing 0-800- 0-114- 114;[...]

  • Page 92

    Warranty 74 Intel® Server Chassis SC5300 User Guide W arranty Limited Warranty for Intel ® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel ® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and in st[...]

  • Page 93

    Warranty Intel® Server Chassis SC5300 User Guide 75 Warranty Limitations and Exclusions These warranties replace al l other warra nties, expr essed or implied including, but not limited to, the implied warranties of merchantability and fitne ss for a particular purpose. Intel makes no expressed warranties beyond those stat ed here. Intel disclaims[...]

  • Page 94

    Warranty 76 Intel® Server Chassis SC5300 User Guide How to Obtain Warranty Service To obtain warranty service for this Product, you ma y contact Intel or your authorized distributor. North America and Latin America  To obtain warranty repair for the product, please go to the following Web site to obtain instructions: http://support.intel.com/s [...]