The rules should oblige the seller to give the purchaser an operating instrucion of Graco 24J396, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Graco 24J396 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Graco 24J396. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Graco 24J396 should contain:
- informations concerning technical data of Graco 24J396
- name of the manufacturer and a year of construction of the Graco 24J396 item
- rules of operation, control and maintenance of the Graco 24J396 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Graco 24J396 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Graco 24J396, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Graco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Graco 24J396.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Graco 24J396 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Instr uctions GBL 7500 Bo x Lubricator Pump GBL Shaft Rotation/Lo w Le vel Alarm Pump 3A2257C EN GBL 7500 Bo x Lubricator Pump: Fully enc losed, self-lubricati ng, precision, metering pump capable of pumping small flows of either mineral or synthetic oil to machinery injection points. For prof essional use only . GBL Shaft Rotation/Low Le vel Alarm[...]

  • Page 2

    Warnings 2 3A2257C Wa r n i n g s The f ollowing w ar nings are f or the setup , use , grounding, maintenan ce, and repair of this equipme nt. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazard symbols ref er to procedur e-specific risks. When these symbols appear in the body of this manual , ref er ba ck to these W a[...]

  • Page 3

    Warnings 3A2257C 3 EQUIPMENT MISUSE HAZARD Misuse can caus e death or ser ious injur y . • Do not oper ate the unit when f atigued or under the influence of drugs or alcoh ol. • Do not e xceed the maxim um working pressure or temper ature rating of the low est rated system compo - nent. See Te c h n i c a l D a t a in all equipme nt manuals. ?[...]

  • Page 4

    Warnings 4 3A2257C Pressure Relief Pr ocedure 1. Stop lube pu mp. 2. If installed, close oil supply v alv e located upstre am from pump. 3. If installed, open drain v alv e located downst ream from the pump . 4. Slowly cr ack open fluid line fit tings to relie ve pr es- sure. Installing the Pump Gr ounding Ensure the reservoir is properly grou nded[...]

  • Page 5

    Setup 3A2257C 5 b . F or all installations (whether the tube needs to be tr immed or ca n be used wit hout tr imming), press strainer onto end of the suction tube until it “bottoms” (F IG . 3). 4. Orient pump so the roller bearing on the bottom of the pump is aligned with the cam insid e the reser- vo ir. 5. Install pump on the reser v oir by a[...]

  • Page 6

    Setup 6 3A2257C Suction Fed Models (F IG . 4) 1. Remov e the sight w ell plug (1) and outlet plug (5 ). Discard outlet plug (5). 2. Fill the sight well (2) to th e top with appropriately fil- tered oil. 3. Operate th e hand priming assembly (3) until t he oil le vel dro ps below the end of th e drip tube (4). 4. Apply th read sealant (user supp lie[...]

  • Page 7

    Setup 3A2257C 7 Pressure Fed Models (F IG . 6) NO TE: In the f ollowing instructions , the fill line ref ers to the inlet line. 1. Remov e and d iscard the inlet p lug (1) and o utlet plug (5). 2. Apply thread sealant (user supplied) to fill line fitting. 3. Connect fill line to inlet (2). 4. T orque fill line fitting to 85 + 10 in. lbs (9.60 + 1.1[...]

  • Page 8

    Setup 8 3A2257C Connecting Lube Lines to Pump: Suction, Gravity and Pressur e Fed Pump Models Only NO TE: The lube line ref ers to the outlet line supplying lubricant to the lubr ication points. 1. Apply th read sealant (user supplied ) to lube line f it- ting. 2. Connect lube line to pump out let (6), (F IG . 8)(also see pages 15 and 16). 3. T orq[...]

  • Page 9

    Setup 3A2257C 9 3. For Suction Fed and Gravity Fed models onl y: With the lubricator oper ating, count the dr ops from the drip tube (4) falling into the sight w ell (2) fo r one minute . The number of drops seen f a lling in the sight well equals the amount of oil discha rged by the pump . See Specifi- cations , page 10 f or additional inf or mati[...]

  • Page 10

    Specifications 10 3A2257C Specifications Ta b l e 1 Drops per Stroke T able Section of T able A pplies to Suction and Gra vity Fed Models Only • Allow able viscosity range independent of te mperature: 80-50 00 SUS. • Strok es/Minute - Maxim um - 50; Minimum - 3 • Strok e Length - Maximum 1/ 2 inch (12.7 mm) † Ref er to your manuf acturer’[...]

  • Page 11

    Troubleshooting 3A2257C 11 T roub leshooting * Oil le vel in sight well will rise and f all dur ing nor mal operati on. If condition persis ts refer to Cause/ Solution sections. I Prob lem Cause Solution Pump does not flo w Pump stroke is adjusted to zero . Adjust pump stroke f or desired out- put. See page 8. Pump outlet is plugg ed. Clean/flush p[...]

  • Page 12

    Maintenance 12 3A2257C Maintenance Sight W ell Fills With Oil The oil le vel in the sight well (2) will rise and fall slightly during pump operation . Should the oil le vel in t he sight well rise abov e the dr ip tube (4): 1. Remove the sight well plug ( 1). 2. Allow the pump to continue to opera te until the oil le vel has dropped belo w the drip[...]

  • Page 13

    Technical Data 3A2257C 13 Te c h n i c a l D a t a * Sensor output will open at 10 0-200 psi (0.68 MP a, 6.89 bar). Suction, Gravity Pressure Fed Bo x Lubricator Pump or Shaft Rota tion Alarm Pump Maximum W orking Pressure US Metric All 3/16” Piston Models 7500 psi 51.7 MP a, 517 bar All 1/4” Piston Models 6000 psi 41.4 MP a, 414 bar All 3/8”[...]

  • Page 14

    Technica l Data 14 3A2257C Pump Dimensions Dimension Inches mm A 3.10 76.20 B 1.97 50.04 C 0.50 12.70 D Pump Min. 2.58 Pump Max. 3.18 Pump Min. 65.53 Pump Max.78.23 E5 . 3 7 1 3 6 . 4 0 F Min. 4.14 Max 4.90 Min. 105.20 Max 124.50 G 1.50 38.10 H 0.50 12.70 J 0.50 12.70 K 0.39 9.90 L 0.92 23.37 M 0.28 7.11 N 5.40 13 7.20 P 3.85 97.79 R 10.13 257.18 K[...]

  • Page 15

    Technical Data 3A2257C 15 Gravity Fed Pressure Fe d Inlet P A Outlet C D Outlet Inlet A B C D[...]

  • Page 16

    Technica l Data 16 3A2257C Suction Fed Outlet C D A P N Inlet[...]

  • Page 17

    Technical Data 3A2257C 17 Alarm Pump C D P N Inlet R Retur n to Reser v oir 1/4 NPT Sensor Output[...]

  • Page 18

    All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/pate nts. Original instructions. This manua l contains English. MM 3A2257 Graco Headquarters: Minneap[...]