Fujitsu 4Gbit/s FC I/O Modules manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Fujitsu 4Gbit/s FC I/O Modules, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Fujitsu 4Gbit/s FC I/O Modules one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Fujitsu 4Gbit/s FC I/O Modules. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Fujitsu 4Gbit/s FC I/O Modules should contain:
- informations concerning technical data of Fujitsu 4Gbit/s FC I/O Modules
- name of the manufacturer and a year of construction of the Fujitsu 4Gbit/s FC I/O Modules item
- rules of operation, control and maintenance of the Fujitsu 4Gbit/s FC I/O Modules item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Fujitsu 4Gbit/s FC I/O Modules alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Fujitsu 4Gbit/s FC I/O Modules, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Fujitsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Fujitsu 4Gbit/s FC I/O Modules.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Fujitsu 4Gbit/s FC I/O Modules item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    39 E Before Reading This Manual Thank you for purchasing the PRIMERGY 4Gbit/s FC I/O Module (hereinafter referred to as this product). This manual explains the 4Gbit/s FC I/O Modules and the Fibre Channel driver (for W indows). Read this manual carefully to handle the product correctly . For details about the Fibre Channel driver , refer to m anual[...]

  • Page 2

    40 Remarks W arning Descriptio ns V arious sym bols are used througho ut this manual. These are provided to em phasize important points for your safety and that of others. The sym bols and their meanings are as follows. Be sure to fully understand these before reading this manual. The following symbols are used to indicate the type of warning or ca[...]

  • Page 3

    41 E Abbrevia tions The following expressions and abbreviations are used to describe the product names used in this manu al. Safety For your safety and that of others, follow the guidelines provided on the following pages concerning the use of this product. Handling th is product W ARN I NG CAUTION Product names Expressions and abb reviations 4Gbit[...]

  • Page 4

    42 Checking the Items Supplied Check that the following items are supplied before using this product. Please contact an office listed in "Appendix B Contact Information" (  pg.75) if any parts are missing. • 4Gbit/s FC I/O Module (this product) • Driver Disk × 1 (CD-ROM) - 4Gbit/s FC I/O Module (PG-FCD201) Drivers CD • User&apos[...]

  • Page 5

    43 E Contents 1 4Gbit/s FC I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 1.2 S pecificati ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 1.3 How to Check the Dri ver [...]

  • Page 6

    44[...]

  • Page 7

    1 4Gbit/s FC I/O Module 45 E 1 4Gbit/s FC I/O Module This chapter explains the features and specifications of this product. 1.1 Overview This product is a Fibre Channel expansion board for use exclusively with BX620 S3 and BX620 S4 server blades. This product is configured with one dual port (2 ports) Fibre Channel controller , it is supplied to co[...]

  • Page 8

    46 1.2 Specifications This product is an expansion board used in order to install fiber channel interface on the server blade. This product has the following features: • Capable of high -speed data transfer at a m aximum rate of 4Gbps. • Y ou can place the connected device away from the ser ver . • Uses thin and light cables so they can be ea[...]

  • Page 9

    1 4Gbit/s FC I/O Module 47 E 1.3 How to Check the Driver V ersion The following explains the procedure to check the driver version. 1 Click the "Start" button → "Settings" → "Cont rol Panel" → "Administrative T ools" → "Computer Management" in this orde r . 2 Click "Device Manager"[...]

  • Page 10

    48 1.4 4Gbit/s FC I/O Module to ETERNUS Connections This section explains the connection of the 4Gbit/s FC I/O Module and ETERNUS. Fabric connection Connect to the ETERNUS via FC Switch Blade. 1.5 Notes on Replacing the 4Gbit/s FC I/O Module When an operating 4Gbit/s FC I/O Module has been replaced with a new 4Gbit/s FC I/O Module, it may be necess[...]

  • Page 11

    2 Installing the 4Gbit/s FC I/O M odule 49 E 2 Installing the 4Gbit/s FC I/O Module This chapter explains the installation procedure in the server blade. W ARNING CAUTION 2.1 Installing in a Server Blade  Install ing a FC Network Blade on chassis network bl ade slot 3 or ne twork blade slot 4 is necessary in order to co nnect this prod uct to th[...]

  • Page 12

    50 2.1.1 Installation Position of the 4Gbit/s FC I/O Module The 4Gbit/s FC I/O Module is installed in the server blade expansion board slot. 2.1.2 Installation Procedure for the 4Gbit/s FC I/O Module 1 T urn off the server blade where the 4G bit/s FC I/O Module will be installed. → "3.3 Turning Of f the Server" in "Blade Server Sys[...]

  • Page 13

    2 Installing the 4Gbit/s FC I/O M odule 51 E 5 Install the 4Gbit/s FC I/O Module. Make sure the 4Gbit/s FC I/O Module is securely on the slot. 6 Secure the 4Gbit/s FC I/O Module with the scre ws. Secure the 4Gbit/s FC I/O Module with three screws included with this product. 7 Attach the top cover . → "7.2 Removing and Attaching the T op Cove[...]

  • Page 14

    52 3 Connecting Cables This chapter explains points to note when connecting cabl es. CAUTION For details on how to connect the cables, refer to "SilkW orm 4016 Hardware Reference Manual" and "SilkW orm 4016 Qu ickStart Guide".  Connect the cable to the FC Netw ork Blade installed in the BX600 S3 chassis, or the port used by t[...]

  • Page 15

    4 Installing Drivers and Utilities 53 E 4 Installing Drivers and Utilities This chapter explains the p rocedure for installing drivers and utilitie s. • For installing drivers and utility (HBAnyware) at the same time.  "4.1 Automatic Installation"(pg.53) • For installing drivers and utility (HBAnyware) manually .  "4.2 Manu[...]

  • Page 16

    54 1. Click [Next]. 2. Select "Find the best driver for the device", and click [Next]. 3. Check only "CD-ROM drive", and then click [Next]. 4. Click [Next]. 5. Click [Finish]. 7 Click [Finish]. When "System Se ttings Change" appears, click [Y es] to restart the system . 8 Refer to "1.3 How to Check the Driver V er[...]

  • Page 17

    4 Installing Drivers and Utilities 55 E 4.2 Manual Installation Drivers and utilities can be manually installed using the following procedures. 4.2.1 F or Installation on Windows Server 2003  When "Welcome to the Found N ew Hardw are Wizard" appe ars during startup, click [Cancel] . Installing Emu lex PLUS 1 Click the "S tart"[...]

  • Page 18

    56 Installing ***** port Miniport Drive r 1 Click the "Start" button → "Administrative T ools" → "Computer Management" in this order . 2 Click [Device Manager]. 3 Select "Emulex **********" in the "SCSI and RAID controllers" or "Other devices" list and double-click it.  If the disp [...]

  • Page 19

    4 Installing Drivers and Utilities 57 E 12 Check the driver version. •F o r 3 2 B i t 5.1.30 .9 •F o r 6 4 B i t 7.1.30 .9 13 Close the board property window . When installation finishes, perform "4.2.2 Installing HBAnyware" (  pg.57) . 4.2.2 Installing HBAnyware 1 Insert the driver disk (CD-ROM) into the CD-ROM drive, and execute [...]

  • Page 20

    58 4.3 Checking and Updati ng Firmware / BootBIOS There are two methods to check and update Firmware/BootBIOS. The results will bring no difference.  "4.3.1 Using LightPulse Utility / NT"(pg.58)  "4.3.2 Using HBAnyware Utility"(pg.60) 4.3.1 Using LightPulse Utility / NT This product name displayed in LightPulse Utility/NT [...]

  • Page 21

    4 Installing Drivers and Utilities 59 E 7 For the Bo otBIOS version, check the "Revision" value in "Bo ot Bios Firmware". • When the version is "1.70a3", proceed to S tep 11. • When the version is other than "1.70a3", proceed to S tep 8. 8 Click the [Download] button. Although the warning window appears, [...]

  • Page 22

    60 4.3.2 Using HBAnyware Utility This product name displayed in HBAnywar e Utility is "BX600-FC42E - 10:00:**:**:**:**:**:**". The "**:**:**:**:**:**" shows the IEEE address of the 4Gbit/s FC I/O Module. Each 4Gbit/s FC I/ O Module has a unique IEEE address, which is written on the stick er on each 4Gbit/s FC I/O Module. 1 Click[...]

  • Page 23

    4 Installing Drivers and Utilities 61 E 8 For the BootBIOS version , check the "BootBIOS" value in "Boot BIOS". • When the version is "1.70a3", proceed to S tep 13. • When the version is other than "1.70a3", proceed to S tep 9. 9 Click the "Update Firmware..." in "Firmware". When the c[...]

  • Page 24

    62 5 4Gbit/s FC I/O Module Details Setting This chapter explains the 4Gbit/s FC I/O Module details settings.  The setting ef fects are the sa me between the settings set by double -clicking [Device] of [key] after selecting [Registr y] with the radio button in the LightPulse Utili ty/NT settings, and the setting s set by the Global s etting (che[...]

  • Page 25

    5 4Gbit/s FC I/ O Module Details Setting 63 E 5.1 4Gbit/s FC I/O Module Setting There are two methods for this product setting . The results will bring no dif ference.  "5.1.1 Using LightPulse Utility / NT"(pg.63)  "5.1.2 Using HBAnyware Utility"(pg.68) 5.1.1 Using LightPulse Utility / NT This product name displayed in Lig[...]

  • Page 26

    64 4 Select the adapter for which settings are chang ed from the adapter list on the left of the window , a nd double-click "T opology" in "P arameters". When there are two or m ore adapters, refer to "Appendix A How to Identify the Adapter" (  pg.74). 5 Set a value for "New V alue" depending on the connec[...]

  • Page 27

    5 4Gbit/s FC I/ O Module Details Setting 65 E 7 Set a value in "New V alue", check "P ermanent", and click [Change]. When the settings vary for each adapter, remove the check on the "Global". The setting value is calculated as follows: For ETERNUS3000 model 50/GR710 /GR720/GR730/GR74 0/GR820/GR840 • For cluster (MSCS[...]

  • Page 28

    66 8 Double-click "QueueT arget" in "P a rameters". 9 Set "1" (fixed value) in "New V alue", check "Permanent", and click [Change]. 10 Double-click "LinkSpee d" in "Parameter". 11 Set a value in "New V alue", check "P ermanent", and click [Change]. For the set[...]

  • Page 29

    5 4Gbit/s FC I/ O Module Details Setting 67 E • When T opology is 0, QueueDepth is 8, and QueueT arget is 1 for all the adapters: 13 When the settings for all adapters finishe s, select "Exit" from "File" menu, and exit LightPulse Utility/NT . After exiting LightPulse Utility/NT perform " 5.2 Registry Setting" (  [...]

  • Page 30

    68 5.1.2 Using HBAnyware Utility This product name displayed in HBAnyware U tility/NT is "BX600FC42E - - 10:00:**:**:**:**:**:* *". The "**:**:**:**:**:**" shows the IEEE address of the 4Gbit/s FC I/O Module. Each 4Gbit/s FC I/ O Module has a unique IEEE address, which is written on the sticker on each 4Gbit/s FC I/O Module. For[...]

  • Page 31

    5 4Gbit/s FC I/ O Module Details Setting 69 E • When selected the adapter to be set and "Driver Parameters" (Individual setting for each adap ter) In the above diagram, "BX620 S3" represents a local server , and "BX600-FC42E - 10:00:00:00:C9:48:FE:0C" represents an installed 4Gbit/s FC I/O Module. 3 Click [T opology][...]

  • Page 32

    70 For ETERNUS 4000 model 300/ 500 and ETERN US8000 Specify "255". 7 Double-click "QueueT arget" in "Adapter Parameters". 8 Set "1" (fixed value) in "V alue" in "Modify Adapter Parameter", and click [Apply]. 9 Click "LinkSpeed" in "Adapter P arameters". 10 Select the va[...]

  • Page 33

    5 4Gbit/s FC I/ O Module Details Setting 71 E 5.2 Registry Setting 1 Click the "Start" button → "Run..." in this order . 2 Enter a name in "Name" as follows, and click [OK]. regedit The registry editor starts. 3 Follow the paths belo w . HKEY_LOCAL_MACHINE SYSTEM CurrentControlSet Services Disk 4 Check that the [...]

  • Page 34

    72 6 Troubleshooting This chapter explains the troubleshootin g methods when this produ ct is not running properly or when error messages are display ed. 6.1 Checking the Link Status The link status connection can be checked upon system start by starting the Light Pulse BIOS Utility . How to s tart the Li ght Pul se BIOS Utility When this product i[...]

  • Page 35

    6 Troubleshooting 73 E 6.2 T r oubleshooting Check the applicable items listed below if this product does not operate correctly . If the problem is not resol ved even after taking the following measu res, contact an office listed in "Appendix B Contact Information" (  pg.75). *: If the expansion ROM initialization value where this prod[...]

  • Page 36

    74 Appendix A How to Identify the Adapter This chapter explains h ow to identify the adapter . Each 4Gbit/s FC I/O Module has an IEEE Address. T he IEEE Address is on a sticker on the front or rear of this product. For PG-FCD201, there are two adapters and two IE EE Addresses. Due to this there are two IEEE a ddress labels. The IEEE Address value m[...]

  • Page 37

    Appendix B Contact Information 75 E Appendix B Contact Information • Australia: Fujitsu Australia Limited T el: +61-2-9776-4555 Fax: +61-2-9776-4556 Address: 2 Julius A venue (Cnr Delhi Road) North Ryde, Australia N.S.W . 21 13 • China: Fujitsu (China) Holdings Co., Ltd. T el: +86-21-5292-9889 Fax: +86-21-5292-9566 Address: 18F , Citic Square, [...]

  • Page 38

    76 • Singapore: Fujitsu Asia Pte. Ltd. T el: +65-6777-6577 Fax: +65-6771-5502 Address: 20, Science Park Road, #03-01 T eleT ech Park, Singapore Science Park I I, Singapore 1 17674 •T a i w a n : Fujitsu T aiwan Lim ited T el: +886-2-2311-225 5 Fax: +886-2-231 1-2277 Address: 19F , No.39, Section 1, Chung hwa Road T aipei, T aiwan • Thail and:[...]

  • Page 39

    P ● 本書の内容は、改善のため事前連絡なしに変更することがあります。 ● 本書に記載されたデータの使用に起因する、 第三者の特許権およびその他の 権利の侵害については、当社はその責を負いません。 ● 無断転載を禁じます。 ● 落丁、乱丁本は、お取[...]

  • Page 40

    こ のマ ニ ュ ア ルは再生紙 を 使用 し 、 リ サ イ ク ル に配慮 し て 製本 さ れ て い ま す 。 不要に な っ た際は、 回収 ・ リ サ イ ク ル に出 し て く だ さ い 。[...]