Freecom Technologies RCS-M2000T manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Freecom Technologies RCS-M2000T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Freecom Technologies RCS-M2000T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Freecom Technologies RCS-M2000T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Freecom Technologies RCS-M2000T should contain:
- informations concerning technical data of Freecom Technologies RCS-M2000T
- name of the manufacturer and a year of construction of the Freecom Technologies RCS-M2000T item
- rules of operation, control and maintenance of the Freecom Technologies RCS-M2000T item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Freecom Technologies RCS-M2000T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Freecom Technologies RCS-M2000T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Freecom Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Freecom Technologies RCS-M2000T.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Freecom Technologies RCS-M2000T item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Models RCS-M2000T RCS-M2000U IMPOR T ANT NO TICE: T o av oid damage and v oiding y our warr anty , place the unit in its upright position f or a minimum of two hours bef ore oper ating. F or best results, and more enjo yment from y our ne w FREECOM por table air conditioning unit, please read this instruction manual carefully and sav e f or future [...]

  • Page 2

    T O REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NO T EXPOSE THE UNIT T O RAIN OR MOISTURE. DO NO T OPEN CABINET . D ANGEROUS HIGH V OL T A GE IS PRESENT . REFER SER VICING ONL Y TO Q U ALIFIED PERSONNEL. Y our air conditioner contains a refrigerant which is converted from a gas to a liquid by a highl y efficient compressor . It has been designed [...]

  • Page 3

    FEA TURES Thank you f or purchasing the FREECOM RCS-M2000 P or table Air Conditioner . The RCS-M2000 series P or tab le Air Conditioner is designed with many state-of-the art features: • Quiet, durab le caster wheels allow f or easy mov ement and instant spot cooling in any room. • Conv enient, electronic operation panel enab les one-touch cont[...]

  • Page 4

    TRES IMPORT ANT INSTRUCTIONS DE SECURITE A lire attentivement av ant utilisation Sécurité • Ne pas arrêter l'appareil en débranchant la prise de courant en cours de f onctionnement. Ceci pourrait endommager le circuit de contrôle (dommage exclu de la gantie). Utilisez toujours le bouton "ON/OFF" du tableau de commande. • Ne [...]

  • Page 5

    IMPORT ANT SAFETY INFORMA TION PLEASE READ AND FOLLO W ALL SAFETY INFORMA TION AND INSTR UCTIONS BEFORE OPERA TING Y OUR NEW FREECOM AIR CONDITIONER. W ARNING: ELECTRICAL SHOCK HAZARD . F ailure to follo w the saf ety information below can result in se vere personal injury or proper ty damage. • Use this product only with the proper electrical vo[...]

  • Page 6

    PRODUCT P AR TS FRONT VIEW REAR VIEW B E D A G C E F J L H M A. Control P anel B. Horizontal Air Louver (up and down) C. Air Outlet D . V ertical Air Louver (left to right) E. Built-in Handle F . Air Filter G. Condensate Water T ank H. P ower Cor d I. Plug J. Caster Wheels K. P ower Cord Wrap L. Exhaust Vent and Duct Hose Opening M. Exhaust Ducting[...]

  • Page 7

    THE CONTROL P ANEL 1. PO WER ON/OFF Easy push-button control s witch to turn the unit ON and OFF . 2. MODE There are f our different f an speed settings: • F AN—F an only (no cooling) • HI—High f an speed with cooling setting • ME—Medium f an speed with cooling setting • LO—Low f an speed with cooling setting. 3. THERMO CONTROL The [...]

  • Page 8

    BEFORE USING IMPORT ANT : Remov e unit from packaging and discard clear , plastic wrapping. Place unit in its upright position for a minim um of three hours bef ore operating for the fir st time. 1. Place unit on a solid, lev el surface . Operating this unit on une ven or soft surf aces may cause vibr ation, noise, and possible w ater leakage from [...]

  • Page 9

    OPERA TION CA UTION: T o av oid damage and voiding y our warranty , place unit in its upr ight position f or a minimum of tw o hours bef ore operating. DO NO T operate unit without condensate water tank and air filter properly in place. Cooling This unit is intended to cool a 200-400 square f oot area. The unit’ s cooling capacity will vary accor[...]

  • Page 10

    OPERA TION (contd.) 6. Press “A UT O SWING” button on control panel to begin oscillating vertical louvers. The vertical louvers will mov e slowly from left to right and back again f or optimum air distribution. Press b utton again to maintain a desired “fix ed” position to distribute more cooling air to one side of the room. DO NO T adjust [...]

  • Page 11

    A CCESSOR Y INST ALLA TION Window P anel Kit (Optional Accessory) The Window P anel Kit is an accessory which, when used with the Exhaust Duct Kit, will increase cooling efficiency by directing w arm air exhaust out a window and pre v enting outside air from getting into the room. 1. Extend panels to fit in windo w opening. F or v er tical windo ws[...]

  • Page 12

    MAINTENANCE AND CLEANING Emptying Condensate Water T ank When the condensate water tank is full, the “FULL T ANK” indicator light will flash,the unit will sound se ver al initial warning beeps, and the unit will automatically turn off. NO TE: If emptying water tank bef ore “full tank” alert, press “PO WER ON/OFF” button to stop unit if [...]

  • Page 13

    MAINTENANCE AND CLEANING (contd.) Cleaning Air Filter This unit has one air filter . For best results and maximum perf ormance, clean filter ev ery two weeks , or as required by en vironmental conditions. CA UTION: Neglect or f ailure to regularly clean the filter will result in poor efficiency , reduced perf or mance , possible damage to the unit,[...]

  • Page 14

    MAINTENANCE AND CLEANING (contd.) Cleaning Cabinet Exterior W ARNING: ELECTRICAL SHOCK HAZARD : • T ur n off unit and unplug from w all outlet before cleaning. • Ne ver submerse the unit in an y type of liquid or expose to hea vy moisture. • Ne ver spra y , pour , or sponge water directly onto the unit . • Ne ver use brushes, brooms , harsh[...]

  • Page 15

    ST ORA GE NO TE: Optional storage cov er a vailab le f or model M2000T/U (P ar t # RRG9723-55-1). F or information about ordering a storage cov er , consult y our F reecom Dealer . 1. Press “POWER ON/OFF” button to stop unit if it is operating. Unplug power cord from outlet. 2. Remo ve and empty condensate w ater tank. See “Emptying Condensat[...]

  • Page 16

    TROUBLESHOO TING Before contacting a dealer or qualified service technician, please read and check the follo wing: SOLUTION 1. Make sure city po wer supply is normal. 2. Check plug is correctly installed into outlet. 3. Check fuses and household break er s witches. 4. Remov e electrical plug from outlet. Check electri- cal cord and plug f or damage[...]