A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Foster FHG 3L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Foster FHG 3L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Foster FHG 3L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Foster FHG 3L should contain:
- informations concerning technical data of Foster FHG 3L
- name of the manufacturer and a year of construction of the Foster FHG 3L item
- rules of operation, control and maintenance of the Foster FHG 3L item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Foster FHG 3L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Foster FHG 3L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Foster service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Foster FHG 3L.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Foster FHG 3L item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Display Case FHG 2L & FHG 3L[...]

  • Page 2

    1 Foster Refrigerator Environmental Manag ement Policy Product Support and Installation Contra ctors Foster Refrigerator recog nises that its activities, products and services can have an adverse impa ct upon the environment. The organisation is committed to implementing systems and controls to manage, reduce and eliminate its adverse environmental[...]

  • Page 3

    2 Introduction The display case are manufactured in two formats FHG 2L, 2 doors, and the F HG 3L, three doors. There are also Multiplex options that are a combi nation of two FHG 2L cases to make a FHG 4L or a combinatio n of the FHG 2L and FHG 3L to make a FHG 5L. Technical Specification. Model 2 Door 3 Door 4 Door 5 Door External Dimensions (m) H[...]

  • Page 4

    3 Temperature controller It is strongly advised that b efore adjusting any Serv ice Parameters a thorough understanding o f the following instructions should be obtained. Carel PB00F0HB10 Controller Display and Symbols. NOTE: When the buttons are presse d a brief audible signal is emitted; this signal can not be disabled. 1. HACCP: Pressing this bu[...]

  • Page 5

    4 9. Compressor: Illuminated when the co mpressor is running. Flashes when the activation of the compre ssor is delayed by safety times. 10. FAN: Illuminated when the fan starts. Flashes when the activation of the fan is prevented due to extern al disabling or proced ures in pr ogress. 11. DEFROST: Illuminated when defrost is activated. Flashes whe[...]

  • Page 6

    5 3. Confirm by pressing . 4. The display shows the code of the first modifiable type “C” paramete r. Modifying the parameters. After having accessed the parameters, either type “C” or typ e “F”, proceed as follows. 1. Press or until the parameter to be modified is reach ed, when scrolling through an icon appears on the display indicati[...]

  • Page 7

    6 Classification of Parameters The parameters, as well as being divided into type, are al so grouped into logical categories identified by the initial letters or symbols of such parameters. The following t able lists the catego rise and the corresponding letters. Parameter Category Text Icon / Temperature probe parameters ‘Pro’ r Temperature co[...]

  • Page 8

    7 35 c9 Enable autostart with PD operation flag 0 0 0 36 c10 Select Pd by time or pressure flag 0 0 0 37 c11 Delayed compressor delay sec 4 4 4 38 d0 Type of defrost flag 0 1 1 39 dI Interval between defrosts hours 8 6 6 40 dt1 End defrost temperature, evaporator. °C/°F 4.0 20.0 20.0 41 dt2 End defrost temperat ure, aux. evaporator °C/°F 4.0 4.[...]

  • Page 9

    8 Parameter Definitions /2 Measurement stability. Defines the coefficient used to stabili se the temperature reading. /3 Probe display rate Sets the rate at which the temperature display is updated. /4 Probe average (Virtual probe) Used to choose whether to control the tempe rat ure based solely on the roo m probe reading, or alternatively whether [...]

  • Page 10

    9 r3 Operating mode The controller can work as a thermostat an d defrost cont roller (r3 = 0), or as a simple thermo stat in direct operation (r3 = 1), or as a simple thermostat in Reverse- cycle op eration (r3 = 2). Default setting: r3 = 0. r4 Automatic variation of the set point in night time oper ation. Default: 3.0. Not used by Foster r5 Enable[...]

  • Page 11

    10 c11 Delayed compressor delay Not used by Foster Default: c11 = 4 d0 Type of Defrost Sets the type of defrost required. Default: d0 = 0. Foster setting d0 = 1. Hot gas defrost termi nated by evaporator probe or in the event of probe failure by time (see dP1). dI Interval between defrosts. The defrosts are performed peri odically at an in terval e[...]

  • Page 12

    11 d/1 Display defrost probe. Displays the value measured by the defrost probe. Once d/1 has been selected pre ss the button to display the temperature measured by the defrost probe. d/2 Display defrost prob e 2 reading. Not used by Foster. dC Base time for defrost. Not used by Foster Default: dC = 0. d10 Compressor running time. Not used by Foster[...]

  • Page 13

    12 Default: A6 = 0. A7 External alarm detection delay . Not used by foster Default: A7 = 0. A8 Enables alarm ‘Ed1’ and ‘Ed2’. Not used by Foster. Default: A8 = 0 = alarms ‘Ed1’ and ‘Ed2’ disabled. Ado Door switch light management mode. Not used by Foster. Default: Ado = 0. Ac High condenser temperatu re alarm. Not used by Foster. De[...]

  • Page 14

    13 Default: H3 = 0. H4 Disable buzzer. H4 = 0 buzzer enabled. H4 = 1 buzzer disabled. Default: H4 = 0. H5 Function of relay 5 . Not used by Foster. Default: H5 = 3. H6 Lock out Butto ns. Not used by Foster. Default: H6 = 0. H7 Select Keypad. Used to select the type of keypad on the controller. Default: H7 = 0. Use the standard controller. HPr Print[...]

  • Page 15

    14 MCB Siemens 5SY6316 –8 TP 16 Amp 3 Pole 16240209 X X Wiring diagrams The drawings numbers for the display cases are a s follows: FHG2L - 2 door unit single pha se 00-233867-02 FHG2L - 2 door unit three phase 00-233868-02 FHG3L - 3 door unit three phase 00-233869-02[...]

  • Page 16

    15[...]

  • Page 17

    FHG2L - 2 door unit single pha se 00-233867-02[...]

  • Page 18

    FHG2L - 2 door unit three phase 00-233868-02[...]

  • Page 19

    1 FHG3L - 3 door unit three phase 00-233869-02[...]

  • Page 20

    Foster European Operations France Foster Refrigerator France SA Tel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: commercial@fosterfrance.com Germany Foster Refrigerator Gmbh, Tel: (49) 2333 839375. Fax (49) 2333 8393 77. Email: info@foster-gmbh.de Foster Refriger ator Oldmedow Road Kings Lynn Norfolk PE30 4JU Tel: 01553 691122 Fax: 01553 [...]