Equinox Systems RS232-RS485 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Equinox Systems RS232-RS485, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Equinox Systems RS232-RS485 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Equinox Systems RS232-RS485. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Equinox Systems RS232-RS485 should contain:
- informations concerning technical data of Equinox Systems RS232-RS485
- name of the manufacturer and a year of construction of the Equinox Systems RS232-RS485 item
- rules of operation, control and maintenance of the Equinox Systems RS232-RS485 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Equinox Systems RS232-RS485 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Equinox Systems RS232-RS485, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Equinox Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Equinox Systems RS232-RS485.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Equinox Systems RS232-RS485 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    User Guide (V ersion 1.02)[...]

  • Page 2

    RS232 - RS485 Convertor Manual V1.02 28/06/01 i Contents Copyright Information ............................................................................................................................ ii Equinox Warranty Information ............................................................................................................. iii [...]

  • Page 3

    RS232 - RS485 Convertor Manual V1.02 28/06/01 ii Copyright Information Information in this document is subject to change without notice and does not represent a commitment on the part of the manufacturer. The software described in this document is furnished under license agreement or nondisclosure agreement and may be used or copied only in accorda[...]

  • Page 4

    RS232 - RS485 Convertor Manual V1.02 28/06/01 iii Equinox Warranty Information This product is guaranteed by Equinox Technologies UK Limited for a period of 12 months (1 year) after the date of purchase ag ainst defects due to faulty workmanship or materials. One guarantee covers both parts and labour. Service under the guarantee is only provided u[...]

  • Page 5

    RS232 - RS485 Convertor Manual V1.02 28/06/01 iv Equinox Technologies UK Ltd. can not be held responsible for any programming problems which are ‘out of our control’. This type of problem is usually lis ted in the ‘Errata Sheet’ for the particular device being programmed and is available from the silicon vendor. Information contained in thi[...]

  • Page 6

    RS232 - RS485 Convertor Manual V1.02 28/06/01 v Electrom agnetic Compatibility (EMC) Compliance The ‘RS - 232 to RS - 485 Convertor’ is a CE Approved Product. It is designed for use in an ESD controlled environment i.e. development or production. This means, therefore, that the user must ensure that there is no poss ibility of damage from elect[...]

  • Page 7

    RS232 - RS485 Convertor Manual V1.02 28/06/01 vi Technical Support It is often the case that users experience problem s when installing or using a product for the first time. Equinox are unable to answer technical support questions about this product or its use by telephone. If you have a technical support problem, please consult the following list[...]

  • Page 8

    RS232 - RS485 Convertor Manual V1.02 28/06/01 vii Associated Product Documentation This manual provides a detailed description of the ‘RS - 232 to RS - 485 Convertor’ hardware only. For detailed informatio n about the systems in which this module is used and the associated hardware modules and software support products, please refer to the sour[...]

  • Page 9

    [...]

  • Page 10

    RS232 - RS485 Convertor Manual V1.02 28/06/01 1 1.0 Overview The RS - 232 to RS - 485 Convertor module converts RS - 232 levels from a PC COM port to RS - 485 levels suitable for interfacing with the Equinox PRO101, PRO104 and PRO108 Production ISP programmers. The module provide s an optical isolation barrier between the PC COM port and the RS - 4[...]

  • Page 11

    RS232 - RS485 Convertor Manual V1.02 28/06/01 2 2.0 RS232 - RS485 Convertor End Panels Figure 2 Number Description Type 1 RS - 232 Connector DB9 Female 2 Power Connector 2.5mm Power Connector 3 RS - 485 Connector RJ11 4 RS - 485 Connector RJ11 5 Traffic Light Status LED’s 3 - way LED pack Figure 3[...]

  • Page 12

    RS232 - RS485 Convertor Manual V1.02 28/06/01 3 2.1 RS - 232 to RS - 485 Status LED Indicators Figure 4 No LED Colour Status Description 1 Red Indicates that the PC has enabled RS - 485 transmission. This means that the RS - 485 driver has been enabled allowing the convertor to drive the RS - 485 line to the remote system. 2 Yellow Indicates that t[...]

  • Page 13

    RS232 - RS485 Convertor Manual V1.02 28/06/01 4 2.3 J1 RS - 232 Serial Communications Port Connector type: 9 - Way Male D Connector (Female) Purpose: Connects to PC COM port (RS - 232) This connector is an RS - 232 serial port which connects to a spare RS - 232 P C COM (serial) port. The pin - out of this connector is detailed in the table below. T[...]

  • Page 14

    RS232 - RS485 Convertor Manual V1.02 28/06/01 5 2.4 J2 & J4 Isolated RS - 485 Connectors Connector type: FCC68 Socket 6 - Way (Accept RJ11 plugs) Purpose: Connects to RS - 485 remote system e.g. PRO101/4/8 programmers These two connectors are opto - isolate d RS485 connectors for communicating with the remote RS - 485 system(s). The connectors [...]

  • Page 15

    RS232 - RS485 Convertor Manual V1.02 28/06/01 6 3.0 PRO101 – Multi - Channel RS - 485 Oper ation 3.1 Overview It is possible to network up to 16 PRO101 programmers on an RS - 485 network and control them from a single ‘Supervisor PC’ running a single session of the EQTools/ISP - PRO software. This scenario requires that each PRO101 programmer[...]

  • Page 16

    RS232 - RS485 Convertor Manual V1.02 28/06/01 7 3.2 PRO101 Hardware Installation Instructions • Place the PRO101 programmers side - by - side on a flat surface allowing sufficient space in front of each programmer to place the ‘ISP Interface Modules’ and ‘Target Systems’. • Remove the lid of each programmer by removing the four screws i[...]

  • Page 17

    RS232 - RS485 Convertor Manual V1.02 28/06/01 8 4.0 PRO104 – 4 Channel Eurocard Rack Production ISP System 4.1 Overview The PRO104 programmer contains 4 PPM programming modules on an RS - 485 network. These are controlled from a single ‘Supervisor PC’ running the ISP - PRO software. An RS - 2 32 to RS - 485 convertor is required to convert th[...]

  • Page 18

    RS232 - RS485 Convertor Manual V1.02 28/06/01 9 4.2 PRO104/108 Hardware Installation Instructions • Place the PRO104/108 programmer(s) on a flat surface allowing sufficient space in front of each programmer to place the ‘ISP Interf ace Modules’ and ‘Target Systems’. • Plug the 9 - way RS - 232 cable into the port on the RS - 232 to RS -[...]