Emerson 9055E manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Emerson 9055E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Emerson 9055E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Emerson 9055E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Emerson 9055E should contain:
- informations concerning technical data of Emerson 9055E
- name of the manufacturer and a year of construction of the Emerson 9055E item
- rules of operation, control and maintenance of the Emerson 9055E item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Emerson 9055E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Emerson 9055E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Emerson service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Emerson 9055E.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Emerson 9055E item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation and Maintenance Manual f or FCR Equipped Motors and Gearmotors F O R M 9055E Revised May 2013 Emerson Industrial Automation 7120 New Bufngton Road Florence, KY 41042 Application Engineering: 800 626 2093 www .emerson-ept.com Browning, Emerson, Emerson Indu strial Automa tion and Intelli gear are tradem arks of Emerson Electric Co. o[...]

  • Page 2

    2 1 Receipt Inspection Upon receipt, check the condition of the br ake - should the motor or br ak e or e v en the pac kaging be damaged in any wa y , inf orm the carr ier . Check the br akemotor and gear nameplate to mak e sure it conf orms with the order specifications (mounting arrangements , etc.) 1.1 Brakemotor Nameplate Installation Instruct[...]

  • Page 3

    3 2 Storage Store the equipment in a clean, dr y place that is protected from shocks , vibration and temper ature fluctuations and with relativ e humidity le v els of less than 90%. 3 Installation 3.1 Mechanical Installation Allow a minim um of 8.3 inches of clearance between the f an cov er guard of the br akemotor and an y surf ace to allow room[...]

  • Page 4

    4 Installation Instructions 3.5 Wiring diagrams 3.4 Electro-ma gnetic characteristics @ 20°C + 5% IntelliGear ® wiring with ESFR card (see IntelliGear Plus™ Manual F or m 9112). SO6 Rectifier SO8 Rectifier 230v or 460v or 380v 460v or 380v 230v Three phase brak e motors operated from a fixed frequency po wer supply are supplied with onboard [...]

  • Page 5

    5 Installation Instructions Three phase brak e motors operated from a variable frequency po wer supply are designed with onboard rectifiers in the conduit bo x to allow powering the brak e rectifier from a 115V or 230V fixed frequency single phase pow er separate from the motor/VFD b ut inter lock ed with that power source such that both motor a[...]

  • Page 6

    6 4 Maintenance* 4.1 Adjustments Adjusting the air gap: (Figure 1) The air gap needs to be adjusted when the mechanical release mechanism no longer functions normally . • Unscrew the man ual release handle(16) when it is supplied. • Unscrew the 4 co ver scre ws (40) which are securing the f an cover guard (23) on the motor . •Remov e[...]

  • Page 7

    7 Installation Instructions 4.2 Disassembly and reassemb ly of the brake manual release (default option) (Figure 2) Disassembly of the br ake manual release: • Unscrewthehandle(16)oftheman ualrelease(14) (if supplied). • Remov ethefanco verscrews(40)whichare securing the fan co ver (23) i[...]

  • Page 8

    8 5 Exploded View and P ar ts List For FCR Brake Motors 5.2 FCR parts list 6 Replacement brakemotors and Repair P ar ts 6.1 Procedure All orders or quotes f or replacement par ts must be accompanied b y:   • Thecompletemotortype,numberofunitsandthecompletenameplateinf ormation.   • Ref erenc[...]

  • Page 9

    9 Installation Instructions Abnormal Noise Noisy Motor Motor heating up abnormally Motor will not star t Brak e does not release Brak e releases but is v er y noisy Brak e releases but br aking is insufficient Originating from motor or dr iv en machine? Mechanical causes: if noise persists after s witching off the electrical power supply . - Beari[...]

  • Page 10

    10 Browning, Emerson, Emerson Indu strial Automa tion and Intelli gear are tradem ar ks of Emerson Electric Co. or one of its a ffiliated c ompanies. ©2008, 2009, 2013 Emerson Powe r T ransmission Corps., All Rights Rese rved. MCIM13005E • Form# 9055E • Printed in USA[...]