Desa CVDR18 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa CVDR18, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa CVDR18 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa CVDR18. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa CVDR18 should contain:
- informations concerning technical data of Desa CVDR18
- name of the manufacturer and a year of construction of the Desa CVDR18 item
- rules of operation, control and maintenance of the Desa CVDR18 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa CVDR18 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa CVDR18, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa CVDR18.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa CVDR18 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    NA TURAL GAS LOG WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light [...]

  • Page 2

    2 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is con- vertible for use with propane/LP , using the GA9000 or GA9100 pilot kit. SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the[...]

  • Page 3

    3 901048 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification (VVDR24 Shown) OPTIONAL PRODUCT FEA TURES ON/OFF SAFETY VALVE/ PILOT KIT AND PROPANE/LP CONVERSION An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You mus[...]

  • Page 4

    4 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventila- tion . All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Spac[...]

  • Page 5

    5 901048 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR APPLIANCE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install appliance plus any adjoining rooms with doorless passageways or ventilation grills between [...]

  • Page 6

    6 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Or Remove Door into Adjoining Room, Option 3 Ventilation [...]

  • Page 7

    7 901048 OWNER’S MANUAL INST ALLA TION WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimne[...]

  • Page 8

    8 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 5. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed. Damper Cla[...]

  • Page 9

    9 901048 OWNER’S MANUAL INST ALLA TION Continued Figure 7 - Checking Gas Joints HEARTH KIT ASSEMBLY AND INSTALLATION Kit Assembly Note: The following instructions apply to both standard single bar burners, as well as dual flame “U” style burners. Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. 1. De[...]

  • Page 10

    10 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS 2. Attach the pilot gas line to the pilot out- let of the gas control v alve and tighten. Connect the thermocouple to the rear of the gas control valv e. See Figure 12. Do not overtighten. If using propane/LP g as, see Changing Pilot Orif ice, page 11. 3. Install the inlet fitting into the inlet [...]

  • Page 11

    11 901048 OWNER’S MANUAL TESTING BURNER FOR LEAKS 1. Generously apply soapy solution to all connections. WARNING: Never check for gas leaks with open flame. 2. Light the b urner with the shut-off v alve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 12). 3. Inspect all connections for bubb[...]

  • Page 12

    12 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS LIGHTING INSTRUCTIONS OPERA TING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. BEFORE LIGHTING smell all around the appliance area for gas. Be su[...]

  • Page 13

    13 901048 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE REMEDY OBSERVED PROBLEM Continued Note: For additional help, v[...]

  • Page 14

    14 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re[...]

  • Page 15

    15 901048 OWNER’S MANUAL OBSERVED PROBLEM When ignitor button is pressed, there is no spark at pilot (GA9000 Only) When ignitor button is pressed, there is spark at pilot but no ignition (GA9000 Only) Pilot lights but flame goes out when control knob is released (GA9000 Only) Burner does not light after pilot is lit (GA9000 Only) Delayed ignition[...]

  • Page 16

    16 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS ILLUSTRA TED PA R T S BREAKDOWN RADCO BURNER MODELS CVSR18, CVSR24, CPVSR18, AND CPVSR24 3 1 8 6 4 2 10 11 12 13 14 15 16 23 17 22 21 20 19 18 7 5 9 9 Amherst Round Oak Logs Oxford Round Oak Logs[...]

  • Page 17

    17 901048 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. RADCO BURNER MODELS CVSR18, CVSR24, CPVSR18, AND CPVSR24 KEY PART NUMBER FOR NO. CVSR18 CVSR24 CPVSR18 CPVSR24 DESCRIPTION QTY. 1 901058-01 901058-01[...]

  • Page 18

    18 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS ILLUSTRA TED PA R T S BREAKDOWN RADCO BURNER MODELS CVDR18, CVDR24, AND CVDR30 3 13 1 8 6 4 2 10 7 5 9 9 14 14 20 19 18 15 16 21 17 11 12 Berkshire Split Oak Logs[...]

  • Page 19

    19 901048 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. RADCO BURNER MODELS CVDR18, CVDR24, AND CVDR30 KEY PART NUMBER FOR NO. CVDR18 CVDR24 CVDR30 DESCRIPTION QTY. 1 901058-01 901058-01 901058-01 Brass 3/[...]

  • Page 20

    20 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the ad- dress listed on the back page of this manual. MANUAL SHUTOFF VALVE GA501[...]

  • Page 21

    21 901048 OWNER’S MANUAL ACCESSORIES Continued DECORATIVE ASH BED CONTROL COVER - CDABK (Not Shown) An attractive way to cover control knob and piezo ignitor. 18" ORNAMENTAL GRATE ENHANCER - GA9350 (Not Shown) For 18" models only. Additional decoration for front grate. 24" ORNAMENTAL GRATE ENHANCER - GA9360 (Not Shown) For 24"[...]

  • Page 22

    22 901048 FOR VENTED NA TURAL GAS LOGS RADCO BURNERS NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___[...]

  • Page 23

    23 901048 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________[...]

  • Page 24

    LIMITED WARRANTY VANGUARD VENTED GAS LOGS DESA International warrants this product to be free from defects on burner system for three (3 ) years and logs for a lifetime f rom the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim unde[...]